• Title/Summary/Keyword: temperature loading

Search Result 1,316, Processing Time 0.026 seconds

Simultaneous Removal of SO$_2$ and NO by Using Metal Oxide( II ) -Oxidative Sorption of SO$_2$ by Metal Oxide- (금속산화물을 이용한 이산화황과 산화질소의 동시재거( II ) -금속산화물과 이산화황의 반응-)

  • 신창섭
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.26-33
    • /
    • 1991
  • To remove SO$_2$ from flus gas, cupric oxide, manganese oxide and iron oxide were studied with varying loading value. The experiment was carried out in a flow reactor and the reactants were prepared by impregnation method using alumina. The reaction temperature was varied from 30$0^{\circ}C$ to 45$0^{\circ}C$. Experimental results showed that all of these metal oxides were effective on SO$_2$ removal reaction and cupric oxide was the best reactant. The sample with 10wt% loading value was better reactant than with 20wt% because in case of 20wt% loading, metal dispersion on the alumina surface was not uniform. And the SO$_2$ removal efficiency was increased with the reaction temperature.

  • PDF

Three-dimensional and free-edge hygrothermal stresses in general long sandwich plates

  • Ahmadi, Isa
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.275-290
    • /
    • 2018
  • The hygrothermal stresses in sandwich plate with composite faces due to through the thickness gradient temperature and (or) moisture content are investigated. The layer-wise theory is employed for formulation of the problem. The formulation is derived for sandwich plate with general layer stacking, subjected to uniform and non-uniform temperature and moisture content through the thickness of the plate. The governing equations are solved for free edge conditions and 3D stresses are investigated. The out of plane stresses are obtained by equilibrium equations of elasticity and by the constitutive law and the results for especial case are compared with the predictions of a 3D finite element solution in order to study the accuracy of results. The three-dimensional stresses especially the free edge effect on the distribution of the stresses is studied in various sandwich plates and the effect of uniform and non-uniform thermal and hygroscopic loading is investigated.

Development of Load apparatus for Motor (모터 부하시험을 위한 부하인가 장치 개발)

  • Lim, Byung-Ju;Park, Chang-Dae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.26-32
    • /
    • 2009
  • We have constructed loading apparatuses to electrical motor with a powder brake and a oil pump for load test of a several ten kilowatt-motor and performed load test with two motors. On operating the loading apparatus with a oil pump, temperature of the oil may excessively increase and fail to operate due to dynamic energy loss of equipment in oil loop. In order to control the oil temperature, factors of the energy loss were analyzed and the quantitative loss was calculated. Load tests of motors with two loading apparatuses constructed were successfully performed and strengths of each apparatus come out on operating.

Evaluation of the delamination strengths in differently processed practical Ag-stabilized REBCO CC tapes under transverse loading

  • Diaz, Mark A.;Shin, Hyung-Seop;Ha, Hongsoo;Oh, Sang-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.34-38
    • /
    • 2019
  • Multilayered high-temperature superconductor coated conductor (CC) tapes are used in an extensive range of applications and are exposed to many stresses such as hoop stress, radial/transverse tensile stress under large Lorentz forces, and thermal stress while cooling if thermal expansion properties differ. Loads induced transversely at the tape surface inevitably create delamination phenomena in the multilayered CC tapes. Thus, delamination behaviors of CC tapes along the c-axis under transverse loading conditions, which can vary based on manufacturing process and constituent layers, must be characterized for applications. The anvil test method was used to mechanically investigate the delamination characteristics of various commercially available Ag-stabilized CC tapes at room temperature and 77 K, finding superior strength at the latter. The wide variations found depended on tape structure and fabrication technique. Fractographic morphologies of delaminated tapes supported the findings under transverse loading conditions.

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

Fatigue performance assessment of welded joints using the infrared thermography

  • Fan, J.L.;Guo, X.L.;Wu, C.W.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.4
    • /
    • pp.417-429
    • /
    • 2012
  • Taking the superficial temperature increment as the major fatigue damage indicator, the infrared thermography was used to predict fatigue parameters (fatigue strength and S-N curve) of welded joints subjected to fatigue loading with a high mean stress, showing good predictions. The fatigue damage status, related to safety evaluation, was tightly correlated with the temperature field evolution of the hot-spot zone on the specimen surface. An energetic damage model, based on the energy accumulation, was developed to evaluate the residual fatigue life of the welded specimens undergoing cyclic loading, and a good agreement was presented. It is concluded that the infrared thermography can not only well predict the fatigue behavior of welded joints, but also can play an important role in health detection of structures subjected to mechanical loading.

An approach for modelling fracture of shape memory alloy parts

  • Evard, Margarita E.;Volkov, Alexander E.;Bobeleva, Olga V.
    • Smart Structures and Systems
    • /
    • v.2 no.4
    • /
    • pp.357-363
    • /
    • 2006
  • Equations describing deformation defects, damage accumulation, and fracture condition have been suggested. Analytical and numerical solutions have been obtained for defects produced by a shear in a fixed direction. Under cyclic loading the number of cycles to failure well fits the empirical Koffin-Manson law. The developed model is expanded to the case of the micro-plastic deformation, which accompanies martensite accommodation in shape memory alloys. Damage of a shape memory specimen has been calculated for two regimes of loading: a constant stress and cyclic variation of temperature across the interval of martensitic transformations, and at a constant temperature corresponding to the pseudoelastic state and cyclic variation of stress. The obtained results are in a good qualitative agreement with available experimental data.

A Study on the loading test for of slab by Fire damaged (화재피해를 입은 RC 슬래브의 재하실험에 관한 연구)

  • Lee, Kyu Min;Kang, Seung Goo;Kim, Dong Jun;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

On Vibration Characteristics Study of Thermo-Visco-Plastic Material Under Periodic Thermal Loading (반복적 열하중을 받는 열탄점소성 구조물의 진동 특성 연구)

  • 김덕관;김승조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.49-54
    • /
    • 1997
  • In this paper, vibration characteristics are considered about thermo-visco-plastic material under periodic thermal loading. When in high temperature region, thermo-visco-plastic structure has a periodic thermal loading, it is very important in an accumulated structure like a spacestation to investigate vibration characteristic, stress-strain characteristic is considered in various 2-D model by finite element method.

  • PDF

Temperature Distribution in Water Cascading Horizontal Retort (열수식 살균기의 온도 분포에 관한 연구)

  • Chung, Myong-Soo;Ahn, Tae-Hoe;Lee, Yong-Gab;Yoo, Moo-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.827-833
    • /
    • 1995
  • Temperature distribution tests for a water cascading horizontal retort utilizing superheated water with overpressure as a heating medium were carried out under three different loading conditions, that is, empty(P-0), half-fully(P-3000) and fully(P-6000) loaded operating conditions. Tank volume and full loading capacity of sterilizer used for this study were about 5,900 liter and 1,140 kg(6000 pouches having 190 g weight each), respectively. Set point condition for sterilization was $122^{\circ}C$, 23 minutes and pressure was maintained in the range of $1.8{\sim}2.0\;kg/cm^2$ during sterilization. For each experiment, time-temperature data and F values were obtained from temperature microprocessor($F_0$ monitor). There were significant variations in the temperature distribution at different positions in the sterilizer. The temperature distribution was also affected by the pouch loading condition significantly. The application of the temperature distribution test to a product (retort pouched curry sauce) was conducted at the fully(P-6000) loading condition. Although heat transfer parameters($f_h\;and\;f_c$), and F values were varied with the position of sterilizer, sensory evaluation showed that the temperature distribution of the sterilizer used in this study didn't affect the quality of retorted curry sauce.

  • PDF