• Title/Summary/Keyword: temperature increasing rate

Search Result 2,155, Processing Time 0.04 seconds

Effects of Sweeping Rate on Magnetic Viscosity of Metal Evaporated Tape

  • Pyung Woo Jang;Young Gu Yoo;Kyung Ho Shin
    • Journal of Magnetics
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 1999
  • Magnetic viscosities of a commercialized metal evaporated tape were measured as a function of sweeping rate in VSM at room temperature. Within several seconds in the viscosity measurement, curves are downward concave and more concave with increasing sweeping rate when magnetization were plotted as a logarithmic function of time. However, magnetization varied as a logarithmic function of time after several seconds. Magetic viscosity coefficient gradually increased with increasing sweeping rate and then kept a constant value at a rate faster than 61.5 Oe/s. It was supposed that magnetic viscosity occurs during field sweeping, which was in good agreement with Sharrock's model qualitatively. Activation volume decreased with increasing sweeping rate, which was due to the fact that magnetic viscosity coefficients increased with sweeping rate while irreversible susceptibilities were not affected by sweeping rate.

  • PDF

A Study on the comparison on Adsorption characteristics of Zeolite and DETOX for the removal of H2S (H2S 제거를 위한 Zeolite와 DETOX의 흡착 특성 비교 연구)

  • Park, Dae-Seok;Lim, Ji-Young;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4675-4681
    • /
    • 2014
  • This study examined the $H_2S$ removal characteristics, such as breakthrough time, adsorption capacity, and adsorption rate of adsorbents between Zeolite 3A and DETOX in terms of the $H_2S$ inflow concentration and adsorption temperature. The adsorption capacity of Zeolite 3A increased with increasing mass flow rate of hydrogen sulfide($H_2S$) inflow, but the breakthrough time decreased. On the other hand, both the adsorption capacity and breakthrough time of DETOX decreased with increasing mass flow rate of $H_2S$ inflow. The adsorption capacity and breakthrough time of Zeolite 3A decreased with increasing adsorption temperature but those of DETOX increased. The adsorption capacity of DETOX was higher than that of Zeolite 3A by a factor of 2.5 - 16.4 because the collision frequency that overcomes the activation energy barrier increased with increasing adsorption temperature. For Zeolite 3A and DETOX, the adsorption rate of $H_2S$ increased with increasing mass flow rate of $H_2S$ inflow and adsorption temperature. The adsorption rate of $H_2S$ for Zeolite 3A was 4 times as much as that for DETOX. For the removal of $H_2S$ in biogas, DETOX had an advantage over Zeolite 3A because DETOX had a much longer breakthrough time and greater adsorption capacity in the temperature range of 308~318K than Zeolite 3A.

Sensitivity of Electroplating Conditions on Young's Modulus of Thin Film (니켈박막의 공정조건에 따른 탄성계수 변화)

  • Kim, Sang-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.88-95
    • /
    • 2008
  • Young's modulus of electroplated nickel thin film is systematically investigated using the resonance method of atomic force microscope. Thin layers of nickel to be measured are electroplated onto the surface of an AFM silicon cantilever and Young's modulus of plated nickel film is investigated as a function of process conditions such as the plating temperature and applied current density. It is found that Young's modulus of plated nickel thin film is as high as that of bulk nickel at low plating temperature or low current density, but decreases with increasing plating temperature or current density. The results imply that the plating rate increases as increasing the plating temperature or current density, therefore, slow plating rate produces a dense plating material due to the sufficient time fur nickel ions to form a dense coating.

Effect of the Ni Content and W Grain Size on the High Temperature Com-pressive Properties of W-Ni Activated Sintered Parts (Ni 함량과 W 결정립 크기에 따른 W-Ni 활성소결체의 고온압축 특성)

  • 박영삼;오승탁;양주환;김영도;문인형
    • Journal of Powder Materials
    • /
    • v.11 no.2
    • /
    • pp.149-157
    • /
    • 2004
  • High temperature deformation behavior of activated sintered W powder compacts was investigated. The compression tests were carried out in the temperature range between 900 and 110$0^{\circ}C$ at the strain rate of $10^{-3}s^{-1}$. The sintered specimens of Ni-doped submicron W powder compacts showed decrease in W grain size with increasing the Ni content. As the result, the flow stress was significantly increased with increasing the Ni content. We obtained Ni-activated sintered W compacts with the relative density of 94 $\pm$ l%and the average grain size of less than 5${\mu}{\textrm}{m}$. A moderate true strain up to 0.60 was obtained without fracture even at 110$0^{\circ}C$ with the strain rate of $10^{-3}s^{-1}$ for the activated W compact despite adding the 1.0 wt%Ni to submicron W powder.

The Effect of Aftertreatment Conditions on the Dyeability of PET Filament (Poly(ethylene terephthalate) filament의 후처리 조건이 염색성에 미치는 영향)

  • Lee, Dae-Soo;Han, Myeong-Hee
    • Textile Coloration and Finishing
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 1990
  • The crystallinity and dyeability of PET filament were studied when the conditions of drawing and heat-setting were varied. The crystaltinity of PET filament was increased as the drawing ratio and heatsetting temperature were increased. The dye uptake and dyeing rate of PET filament were decreased as the drawing ratio was increased. With increasing the heat-setting temperature, however, the dye uptake and dyeing rate were decreased at an early stage, showing the minimum at $160^{\circ}C-180^{\circ}C$ and then increased above that temperature. The thermal shrinkage of PET filament was decreased as the drawing ratio was increased, while increasing as the heat-setting temperature was increased.

  • PDF

The study on formation of platinum thin films for RTD temperature sensor (측온저항체 온도센서용 백금박막의 형성에 관한 연구)

  • 정귀상;노상수
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.911-917
    • /
    • 1996
  • Platinum thin films were deposited on Si-wafer by DC rnagnetron sputtering for RTD (resistance thermometer devices). We investigated the physical and electrical characteristics of these films under various conditions, the input power, working vacuum, temperature of substrate and also after annealing these films. The deposition rate was increased with increasing the input power but decreased with increasing Ar gas pressure. The resistivity and sheet resistivity were decreased with increasing the temperature of substrate and the annealing time at 1000.deg. C. At substrate temperature of >$300^{\circ}C$, input power of 7 w/cm$^{2}$, working vacuum of 5 mtorr and annealing conditions of 1000.deg. C and 240 min, we obtained 10.65.mu..ohm..cm, resistivity of Pt thin films and 3800-3900 ppm/.deg. C, TCR(temperature coefficient of resistance). These values are close to the bulk value. These results indicate that the Pt thin films deposited by DC magnetron sputtering have potentiality for the development of Pt RTD temperature sensor.

  • PDF

Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature (용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰)

  • Ham, Jeonggyun;Kim, Min-Jun;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

Effects of Substrate Temperature on the Morphology of Diamond Thin Films Deposited by Hot Filament CVD (Hot Filament CVD에 의해서 증착된 다이아몬드 박막의 표면형상에 미치는 기판온도의 영향)

  • 형준호;조해석
    • Korean Journal of Crystallography
    • /
    • v.6 no.1
    • /
    • pp.14-26
    • /
    • 1995
  • The growth mechanism of diamond thin films, deposited by Hot Filament CVD, was investigated through observation of changes in their surface morphology as a function of the substance temperature and deposition time. Amorphous carbon or DLC thin films were deposited at low substrate temperature. Diamond films consisting of square-shaped particles, whose surfaces are (100) planes, were deposited at an intermedate temperature. At high substrate temperatures, diamond films consisting of the particles showing both (100) and (111) plane were deposited. The (100) proferred orientation of the diamond films are believed to be due to a relatively high supersaturation during deposition, and the growth condition for the diamond films having (100) preferred orientation can be applied to the single crystal growth since no twins are generated on the (100) plane. The grain size of the diamond films did not change with increasing temperature and its increasing rate with increasing deposition time was the same irrespective of the substrate temperature. However, the nucleation density increased with substrate temperature and its increasing rate with deposition time was much higher for the films deposited at higher substrate temperature.

  • PDF

Compressive Strength Tests on Frozen Siberian Clay (시베리아 동토지역 점성토의 압축강도 시험)

  • Kim, Young-Chin;Martin, Christ
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.97-104
    • /
    • 2008
  • The objective of this study was to investigate the strength characteristics of frozen clay. Compressive strength tests were performed on frozen clay with different water contents at various temperatures. The dry density of specimens and strain rate was kept constant. Test results showed that compressive strength increased with increasing water content and decreasing temperature. The increase in peak strength became more significant the lower the temperature for a given water content. The failure mode changed from brittle to ductile deformation with increasing water content and decreasing temperature. Tests also showed an increase in deformation modulus with increasing peak strength, increasing water content and decreasing temperature.

  • PDF

Deformation Property of TiC-Mo Solid Solution Single Crystal at High Temperature by Compression Test (TiC-Mo 고용체 단결정의 고온 압축변형 특성)

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.625-631
    • /
    • 2014
  • To investigate the deformation properties of TiC-(5-20) mol% Mo solid solution single crystals at high temperature by compression testing, single crystals of various compositions were grown by the radio frequency floating zone technique and were deformed by compression at temperature from 1250K to 2270K at strain rates from $5.1{\times}10^{-5}$ to $5.9{\times}10^{-3}/s$. The plastic flow property of solid solution single crystals was found to be clearly different among a three-temperature range (low, intermediate and high temperature ranges) whose boundaries were dependent on the strain rate. From the observed property, we conclude that the deformation in the low temperature range is controlled by the Peierls mechanism, in the intermediate temperature range by the dynamic strain aging and in the high temperature range by the solute atmosphere dragging mechanism. The work softening tends to become less evident with an increasing experimental temperature and with a decreasing strain rate. The temperature and strain rate dependence of the critical resolved shear stress is the strongest in the high temperature range. The curves are divided into three parts with different slopes by a transition temperature. The critical resolved shear stress (${\tau}_{0.2}$) at the high temperature range showed that Mo content dependence of ${\tau}_{0.2}$ with temperature and the dependence is very marked at lower temperature. In the higher temperature range, ${\tau}_{0.2}$ increases monotonously with an increasing Mo content.