• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.027 seconds

국가 지하수 관측망의 수위 및 온도 자료를 이용한 함양량 산정

  • 박창희;구민호;이대하;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.351-356
    • /
    • 2002
  • Groundwater recharge rate was estimated by applying the groundwater level fluctuation method utilizing Theis (1937) approach with specific yield estimation technique of Shevenell (1996) and the temperature method using observed data from National Groundwater Observation Stations. Results based on analysis of water level observation data of 10 alluvium wells reveal that the recharge rates for 5 wells of Kum river area range 3.7~25.0% and those for 5 wells of Nakdong river area range 3.6~21.7%. Results obtained from the temperature method based on water temperature data indicated that the upward flow resulted from evapotranspiration is dominant for 4 wells of the Kum river area and 5 wells of the Nakdong river area. The other wells showed the downward flow which is related to groundwater recharge in these areas.

  • PDF

Surface Temperature Control of an Insulated Horizontal Pipe under Thermal Radiation Environment (복사효과를 포함하는 수평관 표면의 온도제어)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • Procedures for estimation of insulation thickness for a horizontal pipe for condensation control or personnel protection has been investigated, parallel to the previous work of a vertical wall case. Parameters include pipe diameter, emissivity, thermal conductivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation, specially for the case of high temperature application with low Bi. The effect of surface radiation in such case could be up to 65% of the total. Required insulation thickness for the surface temperature control increases as pipe diameter increases and as surface emissivity decreases. Adequate revision of specifications or standards to include newly invented insulation materials with high emissivity has been also suggested.

A Basic Study on the Estimation of Noninvasive Temperature Distribution in Carcinoma Cell for the Hyperthermia (가온요법을 위한 암조직 세포의 무침습 온도분포 추정에 관한 기초연구)

  • Lee, Myeon-Seop;Kim, Nak-Hwan;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.11-20
    • /
    • 1986
  • In the clincal application of Hyperthermia, tissue temperature measurements are made at only a few selecte4 locations because of patient tolerance and practical clinical limitation. Since it is necessary to know the complete carcinoma cell temperature field in order to treat effectively, The difficulty of making such estimates from only a few point compounded because of the lack of knowledge of the carcinomoma cell blood perfusion characteristics. To solve the temperature on carcinoma cell, A noninvasive method (the finite element method) is used. The simulation results show that the finite element method is promising for estimating the complete corcinoma cell temerature distribution, if some knowledge of the blood perfusion pattern is available.

  • PDF

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Influence of Heat-treatment Temperature on Microwave Absorbing Properities of Ni-Zn Ferrite (Zi-Zn Ferrite의 전파흡수특성에 미치는 열처리온도의 영향)

  • 조성백;권경일;최경구;김성수;김재묵
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.3
    • /
    • pp.177-182
    • /
    • 1992
  • The effect of heat-treatment temperature on the microwave absorbing properties was investigated in Ni0.8Zn0.2Fe2O4 specimens. The composite specimens were prepared by modling and curing the mixture of prereacted ferrite powder and silicone rubber. The measurement of complex permeability and permittivity was made by the reflection/transmission method. The most sensitive material constants with heat-treatment temperature is the imaginary (loss) component of permeability. The higher the heat-treatment temperature, the greater the magnetic loss. The composite specimens with high magnetic loss exhibited superior microwave absorbing properties. The quantitative estimation of microwave absorbing properties were made by plotting the observed material constants on the calculated solution map of impedance-matching.

  • PDF

Characteristics Analysis of Magnetizing Circuit and Fixture considering Temperature Characteristic (온도특성을 고려한 착자회로 및 요크의 특성 해석)

  • Baek, Soo-Hyun;Maeng, In-Jae;Kim, Pill-Soo;Kim, Cherl-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.82-84
    • /
    • 1993
  • A method for simulating general characteristics and temperature characteristics of magnetizing fixture coil of the capacitor discharge impulse magnetizer-magnetizing fixture system using SPICE is presented. This method has been developed which can aid the design, understanding and inexpensive, time-saving of magnetizing circuit. As the detailed characteristics of magnetizing circuit can be obtained, the efficient design of the magnetizing circuit which produce desired magnet will be possible using our SPICE modeling. Especially, The knowledge of the temperature of the magnetizing fixture is very important to forecast the characteristics of the magnetizing circuits tinder different conditions. The capacitor voltage was not raised above 810[V] to protect the magnetizing fixture from excessive heating. The temperature estimation method uses multi-lumped model with equivalent thermal resistance and thermal capacitance.

  • PDF

Temperature Distributions of High Precision Spindle with Built -in Motor (모터내장형 주축의 온도분포해석에 관한 연구)

  • 김용길;김수태;박천홍;김춘배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.624-628
    • /
    • 1996
  • Unsteady-state temperature distributions in the high precision spindle system with built-in motor are studied. For the analysis, three dimensional model is built for the high precision spindle. The three dimensional model includes the estimation on the amount of heat generation of bearing and built-in motor and the thermal characteristic values such as heat transfer coefficient. Temperature distributions are computed using the finite element method. Analysis results are compared with the measured data. Analysis shows that temperature distributions of high precision spindle system can be estimated resonably using the three dimensional model through the finite element method.

  • PDF

Development of High-Temperature Heat Flux Gauge for Steel Quenching (강재 급속냉각용 고온 열유속게이지 개발)

  • Lee, Jungho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.6
    • /
    • pp.323-330
    • /
    • 2010
  • The present study was motivated by increasing demands on quantitative measurements of the heat flux through the water cooling and quenching process of hot steel. The local heat flux measurements are employed by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are directly used to measure the heat flux variation during water cooling and quenching of hot steel. The heat flux can be directly achieved by Fourier's law and is also compared with numerical estimation which is solved by inverse heat conduction problem (IHCP). The high-temperature heat flux gauge developed in this study can be applicable to measure cooling rate and history during the actual cooling applications of steelmaking process. In addition, the measurement uncertainty of heat flux is calculated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard.

Temperature Gradient Estimation of Floating Zone Furnace by Mean Lamellar Spacing Measurement in DS-processed TiAl Alloys

  • Jung, I.S.;Park, Jong-Moon;Wee, D.M.;Oh, Myung-Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.2
    • /
    • pp.82-86
    • /
    • 2015
  • In this study, the temperature gradient of a floating zone (FZ) apparatus, which is very difficult to directly measure, could be estimated by using the relationships between the lamellar spacing of directionally solidified TiAl alloys and the solidification rate, It was found that the calculated temperature gradient of the FZ apparatus was much higher, and almost ten times higher than that of a Bridgman type directional solidification apparatus.

Nondestructive Estimation of Average Wood Moisture Content Using Surface Temperature Rise by Radiation Heating and Moisture Gradient

  • Lee, Hyoung-Woo;Kim, Byung-Nam
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.38-42
    • /
    • 1999
  • Average moisture content of 30mm-thick Korean red pine(Pinus densiflora) was estimated nondestructively and continuously using surface temperature rise by radiation heating and moisture gradient profile in wood. The surface temperature rises increased as surface moisture contents decreased and good relationships were found between surface moisture contents and surface temperature rises at three different feed speeds of 10, 20 and 30 m/min. Average moisture content could be described as a function of surface moisture content and wood thickness.

  • PDF