• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.034 seconds

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

A Study Properties of concrete Recycling Cockle Shells as Fine Aggregate (고막 패각의 콘크리트 잔골재로 재활용 방안에 관한 연구)

  • Kim, Jeong-Sup;Kim, Kwang-Sup;Kim, Pan-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.141-146
    • /
    • 2004
  • 1) As a result of compressive strength experiment, rupture compressive strength showed more increases in specimens of 15% and 20% of Cockle shells in those of non-mixture. Comparing compressive strength between no-mixed Specimens and Specimens of containing Cockle shells, Specimens containing Cockle shells showed higher strength in 60 days and 90 days of age, and as ark Cockle is contained and age is elapsed, compressive strength is also increased In addition, estimation of compressive strength by reactive hardness in concrete using Cockle shells as aggregate shows low reliability. 2) As a result of experimenting compressive strength after heating, Specimens containing Cockle shells and non-mixed Specimens showed similar strength at $200^{\circ}C$, but compressive strength was lowered as content of Cockle shells increased at over $400^{\circ}C$ and heating temperature was higher. It is because Cockle shells was fired by heat and then its adhesion and bonding capacity were lost. 3) To sum up the above experimental results, it is found that using splitted Cockle shells as aggregate for concrete by 10%~20% showed the same or higher compressive strength and shear strength as concretes using general aggregate and it can be used as substitute aggregate of concrete. It is considered that for future use of splitted Cockle shells as substitute concrete aggregate, continuous researches of its durability, applicability and economy are needed.

Remote Real-Time Uranium Concentration Measurement Using the Nitrogen Laser and optode (질소레이저와 광섬유를 이용한 원격제어 실시간 우라늄 농도 측정)

  • Lee, Sang-Mock;Shin, Jang-Soo;Lee, Su-Mi;Koh, Kwang-Nak;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.362-368
    • /
    • 1997
  • The remote real-time uranium concentration analysis using nitrogen laser, optode, photomultiplier and optical fiber is studied. The optode for the remote collection of uranium fluorescence is designed. The fluorescence intensity at time zero is calculated in order to exclude the quenching effect and the temperature fluctuation and used for more precise estimation. The fluorescence change is very sensitive to the uranium concentration change. The method shows the detection limit of 0.06ppm and the linearity between 0.1ppm and 2ppm of the aqueous uranium concentration.

  • PDF

Latent Heat Flux over the Global Ocean

  • Kubota, Masahisa
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.644-648
    • /
    • 2002
  • Though it was difficult of globally monitor latent heat flux aver the ocean for many years, the situation is rapidly changing by the use of satellite data. Since a bulk formula is used to estimate turbulent heat flux using satellite data, we need wind speed, sea surface temperature and specific humidity data. However, it is not easy to accurately estimate specific humidity using satellite data. Now several algorithms for estimating specific humidity have been proposed and applied to construct latent heat flux data sets. Latent heat flux data sets derived from satellite data such as J-OFURO, HOAPS and GSSTF are available at present. Since the algorithm and used satellite data are not the same between them. the characteristics of each data set may be different. Therefore, it is important to clarify the difference between each data set and investigate the cause of the difference in latent heat flux estimates. In this paper we summarize the present state of the art with regard to the turbulent heat flux estimation by using satellite data. Also we present the comparison results of latent heat flux fields including not only satellite-derived flux fields but also analysis fields.

  • PDF

Estimation of Probable Maximum Precipitation in Thailand Using Geographic Information System

  • Kingpaiboon, Sununtha;Netwong, Titiya
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.804-806
    • /
    • 2003
  • Probable Maximum Precipitation (PMP) is essential in the design of hydraulic structures such as dams, weirs and flood control structures. Up to the present, PMP has been derived from any proper single storm which can have a large error. PMP values should be evaluated from many historic heavy storm events from all over the country. Since this can be done at the spots of storm occurring and the calculated PMP from all spots in the country can be correlated. The objectives of this study are therefore to evaluate PMP from historic heavy storm data from 1972 to 2000 by using meteorological method, then to correlate and to present the results using GIS. The maximized rainfall depths can be calculate from depth of heavy rainfall and dew point temperature, and then can be analyzed for each rainfall duration to obtain spatial rainfall distribution by using GIS. The depth-area-duration relationship of maximized rainfall can be obtained and this helps to develop enveloped curves . The results from this study are a set of contour maps of PMP for each rainfall duration for all over the country and the depth-area-duration relationships for the area of 100 to 50,000 km.$^{2}$ at duration of 1, 2 and 3 days.

  • PDF

Bio-Optical Modeling of Laguna de Bay Waters and Applications to Lake Monitoring Using ASTER Data

  • Paringit, EC.;Nadaoka, K.;Rubio, MCD;Tamura, H.;Blanco, Ariel C.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.667-669
    • /
    • 2003
  • A bio-optical model was developed specific for turbid and shallow waters. Special studies were carried out to estimate absorption and scattering properties as well as backscattering probability of suspended matter. The inversion of bio-optical model allows for direct retrieval of turbidity and chlorophyll- a from the visible-near infrared (VNIR) range sensor. Time-series satellite imagery from ASTER AM-1 sensor, were used to monitor the Laguna de Bay water quality condition. Spatial distribution of temperature for the lake was extracted from the thermal infrared (TIR) sensor. Corresponding field surveys were conducted to parameterize the bio -optical model. In-situ measurements include suspended particle and chlorophyll-a concentrations profiles from nephelometric devices and processing of water samples. Hyperspectral measurements were used to validate results of the bio -optical model and satellite- based estimation. This study provides a theoretical basis and a practical illustration of applying space- based measurements on an operational basis.

  • PDF

A Study on the Observation of IRR Camera in Surface Discharge Image (표면방전 현상의 적외선 카메라 관측에 관한 연구)

  • Lim, Jang-Seob;Kim, Jin-Gook;Kim, Hyun-Jong;Lee, Woo-Sun;Lee, Jin;Kim, Duck-Keun;Lee, Hack-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.563-566
    • /
    • 2003
  • The conventional testing as IEC-60587 is widely used in suface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

Estimation Technique of deicing current for configuration of deicing system in conventional line (기존선 해빙시스템 구성을 위한 해빙전류 예측기법)

  • Jung, Ho-Sung;Kwon, Sam-Young;Park, Young;Ahn, Byeong-Lib;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.288-290
    • /
    • 2005
  • Deicing system operated in high speed line is to melt frost or ice freezed in catenary line when the temperature is lower than 0 in winter. The principle of deicing system is to m디t frost or ice by Joule heat of catenary impedance. The performance of deicing is dependant of deicing current determined by the length of deicing section, deicing impedance and current division ratio of catenary line and messenger line. So, We present technique for estimating deicing current in convention line. Deicing impedance is estimated using Carson - Pollaczek, current division ratio of catenary line and messenger line is estimated using voltage drop, and deicing current is estimated using power system data of operation secion for deicing system in this technique. To verify the validity of technique, we compare the estimated current using technique of this paper with deicng current of high speed line.

  • PDF

Effect of Vacuum Annealing on Thin Film Nickel Silicide for Nano Scale CMOSFETs

  • Zhang, Ying-Ying;Oh, Soon-Young;Kim, Yong-Jin;Lee, Won-Jae;Zhong, Zhun;Jung, Soon-Yen;Li, Shi-Guang;Kim, Yeong-Cheol;Wang, Jin-Suk;Lee, Hi-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.10-11
    • /
    • 2006
  • In this study, the Ni/Co/TiN (6/2/25 nm) structure was deposited for thermal stability estimation. Vacuum (30 mTorrs) annealing was carried out to compare with furnace annealing in nitrogen ambient. The proposed Ni/Co/TiN structure exhibited low temperature silicidation and wide range of rapid thermal process (RTP) windows. The sheet resistance was too high to measure after furnace annealing at $600^{\circ}C$ due to the thin thickness (15 nm) of the nickel silicide. However, the sheet resistance maintained stable characteristics up to $600^{\circ}C$ for 30 min after vacuum annealing. Therefore, the low resistance of thin film nickel silicide was obtained by vacuum annealing at $600^{\circ}C$.

  • PDF

Study on the Estimation of Drying Time of Biomass : 1. Larch Wood Chip

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.186-195
    • /
    • 2015
  • This study aims at modeling the rotary drying of wood chips in co-current mode and estimating the drying time of larch (Larix kaemferi) wood chip. Drying data were obtained in a lab. scale fixed bed dryer operating with an air velocity of 1 m/sec. and at hot air inlet temperatures of $100^{\circ}C$, $200^{\circ}C$, and $300^{\circ}C$. The lab. scale fixed-bed drying rates for small, medium and large size larch wood chips that had been dried from 40% wet-based moisture content (MC) to 10% MC at $200^{\circ}C$ drying temperature were 17.3 %/min., 10.2 %/min. and 5.5 %/min., respectively. It was predicted that larch large size wood chips could be dried from 40% MC to 10% MC in about 23.0, 34.6, and 44.7 minutes at $300^{\circ}C$, $200^{\circ}C$ and $150^{\circ}C$, respectively. Expected drying times for medium size chips were about 8.6, 11.2 and 13.2 minutes and those for small size chips were 4.3, 5.5 and 6.4 minutes, respectively.