• Title/Summary/Keyword: temperature estimation

Search Result 1,651, Processing Time 0.027 seconds

An Estimation of the Temperature-dependent Thermal Conductivity for Hybrid-fiber Reinforced Shield Tunnel Lining (하이브리드 섬유보강 쉴드터널 라이닝의 온도의존적 열전도도 추정)

  • Lee, Chang Soo;Kim, Yong Hyok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.99-106
    • /
    • 2012
  • This study presents estimation method of temperature-dependent thermal conductivity by using solution of inverse heat conduction problem. Time and depth temperature distribution data from full-scale fire test were used for estimating temperature-dependent thermal conductivity on hybrid-fiber reinforced shield tunnel lining. At short heating time, estimated thermal conductivity sharply decreased within $100^{\circ}C$. On the other hand, it reflected thermal properties of concrete and effect of steel fiber at heating time of measured maximum heating temperature. Thus arbitrary time should be determined to estimate temperature-dependent thermal conductivity in time zone of measured maximum heating temperature. Estimated temperature-dependent thermal conductivity is similar to results of other study.

Variation of the CO2 Capture Reaction by Ammonia Solution with Temperature (온도에 따른 암모니아 용액에 의한 CO2 포집 반응의 변화 양상)

  • Kim, Soo-Yeon;Choi, Ye-Seul;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.896-904
    • /
    • 2011
  • The features of the capture reaction of $CO_2$ by ammonia solution have been investigated along with the effect of temperature on the reaction based upon computer program-utilizing calculation and thermodynamic estimation. The stable region of $CO{_3}^{2-}$ was observed to increase with temperature and the change of the stable region of $CO{_3}^{2-}$ with temperature was greater than the temperature variation of the stable region of other carbonate species. The distribution diagram for $NH_4{^+}-NH_3$ system was constructed and the rise of temperature resulted in the decrease of the stability of $NH_4{^+}$ ion, which was thought to be due to the endothermic nature of its acidic dissociation. Considering the introduction of $Ca^{2+}$ ion in the carbon capture reaction by $NH_4{^+}$, the temperature was observed to be important in the determination of the order of reaction between carbonate ion and these cations. The removal process of $CO_2$ gas by ammonia solution was presumed to occur in open system and the temperature variations of the concentration of carbonate system species along with their total concentration were calculated for the proper control and design of the real process.

Estimation of Kinetic Parameters of Nonenzymatic Browning Reaction Using Equivalent Time at Reference Temperarture with Linearly Increasing Temperature Profile (정속가열(定速加熱)조건에서 표준온도상당시간(相當時間)을 이용한 비효소적 갈색화 반응의 동력학 파라미터 추정(推定))

  • Cho, Hyung-Yong;Kwon, Yun-Joong;Kim, In-Kyu;Pyun, Yu-Ruamg
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.178-184
    • /
    • 1993
  • The procedure using equivalent time at reference temperature has been assessed for the estimation of kinetic parameters with experimental data. Kinetic studies of nonenzymatic browning reaction in model and food system were carried out with linearly increasing temperature method. These kinetic parameters, n, $k_{ref}$ and $E_a$ of the systems were evaluated from original data in one step by nonlinear least square regression. The one step procedure yielded efficiently accurate parameter estimation. Computer simulated data with the kinetic models were well consistent with experimental data (average correlation coefficient=0.96).

  • PDF

Strength Estimation Model of Early-Age Concrete Considering Degree of Hydration and Porosity (수화도와 공극률을 고려한 초기재령 콘크리트의 강도 예측 모델)

  • 황수덕;이광명;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.137-147
    • /
    • 2002
  • Maturity models involving curing temperature and curing ages have been widely used to predict concrete strength, which can accurately estimate concrete strength. However, they may not consider physical quantities such as the characteristics of hydrates and the capillary porosity of microstructures associated with strength development. In order to find out the effects of both factors on a strength increment, the hydration model and the estimation method of the amount of capillary porosity were established, and the compressive strength test of concrete nth various water/cement ratios was carried out considering two test parameters, curing temperature and curing age. In this study, by analyzing the experimental results, a strength estimation model for early-age concrete that can consider the microstructural characteristics such as hydrates and capillary porosity was proposed. Measured compressive strengths were compared with estimated strengths and good agreements were obtained. Consequently, the proposed strength model can estimate compressive strength of concrete with curing age and curing temperature within an acceptable error.

Design of the Fixed-Bed Catalytic Reactor for Phthalic Anhydride Production: Optimal Reactor Length and Radius Estimation (무수프탈산 생산을 위한 고정층 촉매 반응기 설계: 최적 촉매층 길이 및 반경 추정)

  • Yoon, Young-Sam;Koo, Eun Hwa;Park, Pan-Wook
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1200-1209
    • /
    • 1999
  • Prediction model was composed by optimal parameter estimation from best fitting on reactant temperature profile, inlet and outlet temperature of coolant and yield of dual fixed-bed catalytic reactor(FBCR) which was measured in the industrial field. In order to design the FBCR which could obtain maximum conversion and yield, we investigated the effect of catalyst bed length and reactor radius changes. An uniform activity FBCR showed the best performance at z = 2.8 m of total catalysst bed length in case of reactor radius r = 0.01241 m and z =2.80 m(upper layer: 1.88 m, lower layer: 0.92 m) under reactor radius r = 0.01254 m for a dual activities FCBR. In case of reactor radius changes, the axial temperature profile and maximum radial temperature was rapidly risen for radius increase. The reactor radius decrease showed the opposite result.

  • PDF

A Study on the CFD Analysis and Estimation of the Energy Efficiency of Cryogenic Chamber for Extreme Climate Test (극한 환경 시험을 위한 극저온 챔버의 CFD 해석 및 에너지 효율 평가에 관한 연구)

  • Kang, Yul-Ho;Kim, Min-Kyu;Park, Warn-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.81-88
    • /
    • 2016
  • There are many types of national and international standards for low temperature tests depending on the products. This study conducted CFD analysis and estimation of the energy efficiency of the chamber both with and without a test object by considering variations of COP and specific volume according to temperature. The supply air was located in the upper area to compare the cooling performance for each location using various outlets in mixed ventilated conditions. For cases without the test object, the air temperature of the upper supply and center extract on the opposite side type chamber cooled faster than other areas by 4.3~29.8%. However, for cases with the test object, the object temperature of the upper supply and lower extract type chamber cooled faster than the other areas by 7.2~31.5%. The cooling efficiency of the air inside the chamber and the test object did not show the same pattern, which indicates the need to consider the cooling performance by not only the air but also the test object in the cryogenic chamber design for testing.

Reliability Estimation of Door Hinge for Rome Appliances (가전제품용 경첩의 신뢰성 추정)

  • Kim Jin Woo;Shin Jae Chul;Kim Myung Soo;Moon Ji Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.689-697
    • /
    • 2005
  • This paper presents the reliability estimation of door hinge for home appliances, which consists of bushing and shaft. The predominant failure mechanism of bushing made of polyoxymethylene(POM) is brittle fracture due to decrease of strength caused by voids existing, and that of shaft made of acrylonitrile-butadiene-styrene(ABS) is creep due to plastic deformation caused by excessive temperature and lowering of glass transition temperature by absorbed moisture. Since the brittle fracture of bushing is overstress failure mechanism, the load-strength interference model is used to estimate the failure rate of it along with failure analysis. By the way, the creep of shaft is wearout failure mechanism, and an accelerated life test is then planned and implemented to estimate its lifetime. Through the technical review about failure mechanism, temperature and humidity are selected as accelerating variables. Assuming Weibull lifetime distribution and Eyring model, the life-stress relationship and acceleration factor, $B_{10}$ life and its lower bound with $90\%$ confidence at worst case use condition are estimated by analyzing the accelerated life test data.

Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring (조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.