• 제목/요약/키워드: temperature distribution control

검색결과 662건 처리시간 0.03초

Sap Temperature Distribution of the Xylem and Leaf Water Status of Apple Trees in Relation to Soil Oxygen Diffusion Rates

  • Ro, Hee-Myong
    • Journal of Applied Biological Chemistry
    • /
    • 제43권3호
    • /
    • pp.170-175
    • /
    • 2000
  • A pot-lysimeter experiment was conducted with 3-year-old 'Tsugaru' apple (Malus domestica Borkh) trees to examine the changes in oxygen diffusion rate (ODR) with lateral flow velocity of water through soil. The influence of lateral water flow velocity on water relations and elemental content in leaf, and sap temperature distribution patterns of the xylem of trees were also determined. Trees were grown under four soil water regimes: (1) fast laterally flowing (FWT, $2.50{\times}10^{-4}cm\;s^{-1}$), (2) slow laterally flowing (SWT, $0.25{\times}10^{-4}cm\;s^{-1}$), and (3) stagnant water table (WLT) at 60-cm, and (4) drip-irrigation at -40 kPa of soil matric potential as a control. The rate of $O_2$ diffusion converged near $2{\times}10^{-3}g\;m^{-2}\;min^{-1}$ for FWT and control soils, but decreased below $1{\times}10^{-3}g\;m^{-2}\;min^{-1}$ 40 days after treatment (DAT) for WLT soils. For SWT soils, however, the ODR at 15 cm below the soil surface was similar to that of control, but at 45 cm below the soil surface, ODR was similar to that of the WLT treatment. Leaf water potential of FWT and SWT plants was similar to that of control plants, but the values for SWT plants declined by 98 DAT. Leaf water potential of WLT plants decreased from -1.86 MPa (9 DAT) to -2.41 MPa (59 DAT) and finally down to -2.70 MPa. The sap temperature measured at 1100-hr was lowest at top and highest at bottom for FWT and control plants, but this pattern of SWT and WLT plants was disturbed from 29 DAT. However, for SWT plants, such thermal disturbance of sap temperature disappeared from 63 DAT.

  • PDF

압력 평형식 온도 조절 밸브의 유동특성 연구 (A study on the flow charateristics of temperature control valve by pressure compensation)

  • 김태안;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2001
  • TCV(Temperature control valve by pressure compensation) controls temperature constantly, when it is sending steam or high temperature water to heating device of heat exchanger. For designing TCV, the ratio of piston and hole diameters is one of the important design parameters. Numerical analysis is carried out to elucidate the flow characteristics in the TCV with different port areas of cold and hot waters, using the k-$\epsilon$ turbulence model and Cartesian cut-cell method. Numerical results show that the exit flow rate is mainly affected by pressure distribution in the piston.

  • PDF

내부발열의 확률적 성상을 고려한 슬래브축냉의 최적제어 (A Study on Optimal Control of Slab Cooling Storage Considering Stochastic Properties of Internal Heat Generation)

  • 정재훈
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.313-320
    • /
    • 2015
  • In this paper, a method to obtain the probability distribution of room temperature and cooling load is presented, when the internal heat generation is applied to the system as a disturbance in the air conditioning system with slab cooling storage. The probability distribution of room temperature and the cooling load due to the disturbance were examined in one room of an office building. When considering only the electric power consumption as a probability component, it was found that the effect on room temperature and cooling load is small, because the probability component of the measured electric power consumption in the building is small. On the other hand, when considering the stochastic fluctuations of electric power consumption together with the heat generated by human bodies, the mean value of the cooling load was about 2,300 W and the ratio of the standard deviations was 19% (10 o'clock in second day). It was revealed that the stochastic effects of internal heat generation acting on the air conditioning system with slab cooling storage are not small.

자동차 제어기의 내구수명 평가방안 연구 (A Study on the Evaluation Method for Durability Life of Vehicle,s ECU)

  • 김병우;최범진;조현덕;이도희
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.208-213
    • /
    • 2008
  • In order to assess the reliability of the electronics control unit for vehicles, accelerated life test model and procedure are developed. By using this method, failure mechanism and life distribution are analyzed. The main results are as follows : i) the main failure mechanism is degradation failure that is, junction destruction of a semiconductor resin by high temperature. ii) the life distribution of the electronics control unit for vehicles is fitted well to Weibull life distribution and the accelerated life model of that is fitted well to Arrhenius model. iii) at the result of the life distribution, accelerated life test method is developed, and test time for life assessment will be shortened by 5,000 hours by this test method.

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

유한요소법을 이용한 SCS 절연 웨이퍼의 온도분포 해석 (Analysis of Temperature Distribution using Finite Element Method for SCS Insulator Wafers)

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제5권4호
    • /
    • pp.11-17
    • /
    • 2001
  • Micronization of sensor is a trend of the silicon sensor development with regard to a piezoresistive silicon pressure sensor, the size of the pressure sensor diaphragm have become smaller year by year, and a microaccelerometer with a size less than $200{\sim}300{\mu}m$ has been realized, In this paper, we study some of the bonding processes of SCS(single crystal silicon) insulator wafer for the microaccelerometer. and their subsequent processes which might affect thermal loads. The finite element method(FEM) has been a standard numerical modeling technique extensively utilized in micro structural engineering discipline for design of SCS insulator wafers. Successful temperature distribution analysis and design of the SCS insulator wafers based on the tunneling current concept using microaccelerometer depend on the knowledge about normal mechanical properties of the SCS and $SiO_2$ layer and their control through manufacturing processes.

  • PDF

GTA 오버레이 용접부의 열유동 해석을 위한 용접열원 모델링 (Welding Heat Source Modeling for Heat Flow Analysis of GTA Overlay Welding)

  • 김용래;채현병;김재웅
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.62-66
    • /
    • 2013
  • Overlay welding is carried out to improve the corrosion resistance, wear resistance and heat resistance on the surface of the chemical plant and steelmaking plant structures. In overlay welding, control of the bead size and the temperature distribution of weldment are particularly important because that is directly connected to the improvement of quality and productivity. The aim of this study is to model the welding heat source that is very useful to analyze the bead size and temperature distribution of weldment. To find the welding heat source model, numerical analyses are performed by using FE software MSC-marc.

고유변형도법에 의한 두께 25mm 맞대기용접부의 두께방향의 잔류응력측정 (Measurement of Welding Residual Stress in a 25-mm Thick Butt Joint using Inherent Strain Method)

  • 박정웅;안규백;우완측;허승민
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.67-72
    • /
    • 2013
  • Overlay welding is carried out to improve the corrosion resistance, wear resistance and heat resistance on the surface of the chemical plant and steelmaking plant structures. In overlay welding, control of the bead size and the temperature distribution of weldment are particularly important because that is directly connected to the improvement of quality and productivity. The aim of this study is to model the welding heat source that is very useful to analyze the bead size and temperature distribution of weldment. To find the welding heat source model, numerical analyses are performed by using FE software MSC-marc.

배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발 (Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application)

  • 박동근;석복열;고태국;강형구
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

상하부 2개의 노외계측기를 이용한 축방향 출력분포 감시계통 개발 (Development of Axial Power Distribution Monitoring System Using Two-Level Encore Detector)

  • Chi, Sung-Goo;Song, Jae-Woong;Ahn, Dwak-Hwan;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.294-301
    • /
    • 1989
  • 상하부 2개의 노외계측기, 노입구관 온도 및 제어봉 위치 신호를 이용하여 상세한 축방향 출력분포를 계산할 수 있는 APDMS프로그램을 개발하였다. 상하부 2개의 노외계측기 신호가 제어봉 위치에 의하여 결정된 제어봉 간섭계수와 노입구관 온도에 따른 온도 간섭계수에 대하여 보정된 후 노심 주변출력을 얻기 위하여 보정된 노외계측기 신호에 shape annealing matrix가 적용되었다. 노심의 상하부 경계에서의 출력을 얻기 위해서는 평균 노심출력과 주변출력과의 선형적 관계를 이용한 노심 상하부의 평균출력에 경계점 출력보정계수가 적용되었다. 축방향 출력분포가 2개의 노외계측기에 의해 계산된 상하부 평균 노심출력, 상하부 경계면에서의 출력 및 미리 계산된 노심의 중심 위치에서의 출력을 이용하여 spline approximation에 의하여 계산되었다. 연소도, 출력준위, 제어봉 위치 및 axial offset의 변화에도 불구하고 고리 3호기 4주기에 대하여 BOXER 코드와 APDMS 프로그램에 의해 계산된 축방향 출력분포의 비교는 5% root mean square 오차내에서 일치함을 보여 주었다.

  • PDF