• Title/Summary/Keyword: temperature cycles

Search Result 884, Processing Time 0.027 seconds

Fabrication of Carbon-coated Tin Nano-powders by Electrical Wire Explosion in Liquid Media and its Electrochemical Properties (액중 전기선 폭발법을 이용한 비정질 탄소가 코팅된 주석 나노분말의 제조 및 전기화학적 특성)

  • Kim, Yoo-Young;Song, Ju-Suck;Cho, Kwon-Koo
    • Journal of Powder Materials
    • /
    • v.23 no.4
    • /
    • pp.317-324
    • /
    • 2016
  • Tin is one of the most promising anode materials for next-generation lithium-ion batteries with a high energy density. However, the commercialization of tin-based anodes is still hindered due to the large volume change (over 260%) upon lithiation/delithiation cycling. To solve the problem, many efforts have been focused on enhancing structural stability of tin particles in electrodes. In this work, we synthesize tin nano-powders with an amorphous carbon layer on the surface and surroundings of the powder by electrical wire explosion in alcohol-based liquid media at room temperature. The morphology and microstructures of the powders are characterized by scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and transmission electron microscopy. The electrochemical properties of the powder for use as an anode material for lithium-ion battery are evaluated by cyclic voltammetry and a galvanometric discharge-charge method. It is shown that the carbon-coated tin nano-powders prepared in hexanol media exhibit a high initial charge specific capacity of 902 mAh/g and a high capacity retention of 89% after 50 cycles.

Transdermal Delivery of Porcine Placenta Extracts using Linolenic Acid-based Emulsion Formulations

  • Kim, Dong-Chan;Noh, Sang-Myoung;Park, Ki-Tae;Kim, Young-Bong;Baek, Kwang-Hyun;Oh, Yu-Kyoung
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.5
    • /
    • pp.281-286
    • /
    • 2007
  • For transdermal delivery of porcine placenta extract (PPE), various emulsion formulations were prepared and evaluated. Polysorbate surfactants were used as emulsifiers and various C-18 unsaturated fatty acids as enhancers. The skin permeation of PPE was tested using a cellulose nitrate membrane-loaded Franz cell apparatus. Among emulsifiers, Tween 20 provided higher penetration effect than did Tween 80. Meanwhile, of various fatty acids, linolenic acid (18:3) revealed the highest skin permeation of PPE than the other C-18 unsaturated fatty acids. Stability of PPE emulsions was determined by cycles of freezing and thawing processes. The stability of emulsions depended on the percentage of Tween 20. Minimum 20% of Tween 20 was required to stabilize emulsions at room temperature for several days. Taken together, our results suggest that Tween 20 and linolenic acids might be key components to formulate PPE emulsion to provide the desirable skin permeability and stability.

Mechanical Properties of Cf/SiC Composite Using a Combined Process of Chemical Vapor Infiltration and Precursor Infiltration Pyrolysis

  • Kim, Kyung-Mi;Hahn, Yoonsoo;Lee, Sung-Min;Choi, Kyoon;Lee, Jong-Heun
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.4
    • /
    • pp.392-399
    • /
    • 2018
  • $C_f/SiC$ composites were prepared via a process combining chemical vapor infiltration (CVI) and precursor infiltration pyrolysis (PIP), wherein silicon carbide matrices were infiltrated into 2.5D carbon preforms. The obtained composites exhibited porosities of 20 vol % and achieved strengths of 244 MPa in air at room temperature and 423 MPa at $1300^{\circ}C$ under an Ar atmosphere. Carbon fiber pull-out was rarely observed in the fractured surfaces, although intermediate layers of pyrolytic carbon of 150 nm thickness were deposited between the fiber and matrix. Fatigue fracture was observed after 1380 cycles under 45 MPa stress at $1000^{\circ}C$. The fractured samples were analyzed by transmission electron microscopy to observe the distributed phases.

Electrochemical Properties of $Li_{2}O-P_{2}O_{5}-V_{2}O_{5}$ Glass-ceramics for cathode Material (정극재료용 $Li_{2}O-P_{2}O_{5}-V_{2}O_{5}$계 결정화 유리의 전기화학적 특성)

  • 손명모;이헌수;김종욱;김윤선;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.652-657
    • /
    • 2001
  • Vanadate glasses containing 10~20mol% glass former, P$_2$O$_{5}$ were prepared by melting the batch in platinum crucible and quenching on the copper plate. Li$_2$O-P$_2$O$_{5}$-V$_2$O$_{5}$ glass-ceramics having LiV$_3$O$_{8}$ were obtained by heat-treatment of this glass in crystallization temperature. The glass-ceramics showed singnificantly good capacity and long cycles life according to heating condition. In this paper, we described electrochemical properties during crystallization process and found the best crystallizaton condition of Li$_2$O-P$_2$O$_{5}$-V$_2$O$_{5}$ glass as cathode material. Li$_2$O-P$_2$O$_{5}$-V$_2$O$_{5}$ glass-ceramics heat-treated at 233$^{\circ}C$ for 3 hors showed good rechargeable capacity of 220mAh/g in the cycling range between 2.0 and 3.9V.en 2.0 and 3.9V.

  • PDF

Anode Characteristics of Tin Oxide Thin Films According to Various Si Additions for Lithium Secondary Microbattery (Si 첨가에 따른 리튬 이차 박막 전지용 주석 산화물 박막의 음극 특성)

  • 박건태;박철호;손영국
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.1
    • /
    • pp.69-76
    • /
    • 2003
  • For lithium secondary microbattery anode, the tin oxide thin films with Si addition (0, 2, 6, 10, 20 ㏖%) were prepared with R.F. magnetron sputtering at substrate temperature of 30$0^{\circ}C$ and Ar:O$_2$=7:3 atmosphere. As Si addition amount increased, Si-O bonding density increased and Sn-O bonding density decreased. The addition of optimum Si amount led the decrease of Sn oxidation state so that the irreversible capacity reduced and cycle characteristic enhanced during charge-discharge test. SnO$_2$films with 6 ㏖% Si had the highest reversible capacity of 700 mAh/g after 100 cycles.

Seasonality of shellfish gathering using oxygen isotope analysis of Crassostrea gigas from the Neolithic Yeondae-do shell midden site, Tongyeong, Korea (산소동위원소 분석을 이용한 신석기시대 연대도 패총의 굴 (Crassostrea gigas) 채집 계절성 연구)

  • An, Deogim;Lee, Insung
    • The Korean Journal of Malacology
    • /
    • v.31 no.1
    • /
    • pp.43-48
    • /
    • 2015
  • Oxygen isotope ratios (${\delta}^{18}O$) of three Pacific oyster (Crassostrea gigas) specimens from the Neolithic Yeondae-do shell midden site, Tongyeong, Korea, were analyzed to determine the seasonality of shellfish gathering and site occupation. Oxygen isotope samples were taken from the left valve hinge sections of the specimens. Oxygen isotope values ranged between -0.1 ‰ and -2.4 ‰, between -0.2 ‰ and -2.9 ‰, and between 0.3 ‰ and -2.8 ‰ in oyster specimen #one, #two and #three, respectively. The isotope profiles showed seasonal temperature cycles, providing information related to the seasonality of shellfish gathering and site occupation. Hinge-edge oxygen isotope values of the specimens showed decreasing trends after passing through maximum values (winter), indicating that they formed during spring. Thus it can be assumed that during spring season, oysters were gathered and the site was occupied.

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

The Performance Evaluation of R407C and R410B in a Residential Window Air-Conditioner

  • Kim, Man-Hoe;Shin, Jeong-Seob;Kim, Kwon-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.148-157
    • /
    • 1998
  • This study presents test results of a residential window air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests has been carried out for the basic and liquid-suction heat exchange cycles in a psychometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-suction heat exchange cycle was also considered to improve the system performance. Test results were compared with those for the basic R22 system. The modified system with a liquid-suction heat exchanger increased cooling capacity and energy efficiency by up to 5%.

  • PDF

The Characteristics of Heating Performance on Small Sized Ammonia Absorption System (소형 암모니아 흡수식 냉난방기의 난방성능 특성)

  • Jin, Byoung-Ju;Oh, Seung-Taek;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Sim-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.120-123
    • /
    • 2008
  • Refrigeration plants using absorption principles have been around for many years with initial development taking place over 100 years ago. Although the majority of absorption cycles are based on water-LiBr cycle, many applications exist where ammonia-water can be used, especially where lower temperatures are desirable. In both systems water is used as working fluid, but in quite different ways: as a solvent for the ammonia system, and as refrigerant for the lithium bromide system. This explains that the lithium bromide absorption system is strictly limited to evaporation temperatures above $0^{\circ}C$. The main industrial applications for refrigeration are in the temperature range below $0^{\circ}C$, the field for the binary system ammonia-water.

  • PDF

A study on the detection method of inner's crack of STS304 pipe using Ultrasonic Testing (초음파 검사법을 이용한 STS304 배관재 내부 균열 측정 방법에 대한 연구)

  • Hwang, Woong-Gi;Lee, Kyung-Min;Woo, Young-Kwan;Seo, Duck-Hee;Lee, Bo-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.415-418
    • /
    • 2011
  • Thermal fatigue is one of the life-limiting damage mechanisms in the nuclear power plant conditions. The turbulent mixing of fluids of different temperatures induces rapid temperature changes to the pipe wall. The successive thermal transients cause varying cyclic thermal stresses. These cyclic thermal stresses cause fatigue crack nucleation and growth similar to the cyclic mechanical stresses. The aim of this study was to fulfil the need by developing an real crack manufacturing method, which would produce realistic cracks. The test material was austenitic STS 304, which is used as pipelines in the reactor coolant system of a nuclear power plants. In order to fabricate thermal fatigue crack similar to realistic crack, successive thermal transients were applied to the specimen. Thermal transient cycles were combined with heating (60sec) and cooling cycle (30sec). And, In order to identify ultrasonic characteristic, it was performed the ultrasonic reflection measuring method for the fabricated specimen. From the results of ultrasonic reflection measuring testing, it was conformed that A-scan results(average 83% of real crack depth) for the TFC reference specimen was more enhanced NDT reliability than results(average 38% of real crack depth) for the EDM notch reference specimen.

  • PDF