• Title/Summary/Keyword: temperature cycles

Search Result 884, Processing Time 0.028 seconds

Effects of Milk Protein-Gum Conjugates on The Characteristics of The Dough and Staling of Bread Made of Frozen Dough During Freeze-Thaw Cycles (우유단백질-검류 복합체 첨가가 제빵용 반죽의 물리적 특성과 식빵의 노화에 미치는 영향)

  • Yun Young;Kim Young-Ho;Kim Young-Su;Choi Sung-Hee;Eun Jong-Bang
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • Milk protein-gum conjugates were prepared by Maillard reaction and added to dough to investigate the possibile use of them as anti-staling agents in bread Four different types of conjugates were added to dough, i.e., $casein-\kappa-carrageenan$ (CK), casein-sodium alginate (CA), $whey-\kappa-carrgeenan$(WK) and whey-sodium alginate (WA). Their addition to flour increased the gelatinization temperature, water absorption and development time of the dough. Extensogram showed the increased resistance to extension of the doughs resulting from the addition of the conjugates. Moisture content of the breads decreased during storage at $5^{\circ}C$ for 4 days. The breads added with conjugates had lower extents of the decreases than non-treated degrees and maintained higher moisture content than non-treated bread after 3 freeze-thaw cycles. The storage degrees at $5^{\circ}C$ for 4 days affected the increased bread hardness, but, addition of WA conjugate decreased extents of the increases. Therefore, milk protein-gum conjugates, especially WA conjugate, contributed to retarding staling of breads

The effect of temperature changes on force level of superelastic nickel-titanium archwires (온도 변화가 교정용 니켈-티타늄 호선의 하중값에 미치는 영향)

  • Chun, Kyoung-Ae;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.432-439
    • /
    • 2007
  • The purpose of this study was to evaluate the influence of intraoral temperature changes on the orthodontic force level of a superelastic nickel-titanium alloy wire. Methods: Nickel-titanium archwires of $0.016"{\times}0.022"$ thickness were tested with a three point bending test setup, and temperature changes were applied. The force level changes according to temperature changes were measured at a 1.5 mm deflection during the loading phase and a 1.5 mm deflection during the unloading phase from a deflection to 3.1mm. Ten cycles of thermal cycling from baseline $(37^{\circ}C)$ to cold $(20^{\circ}C)$ or hot $(50^{\circ}C)$temperature were applied. Results: Alter thermal cycling, the force level during the loading phase decreased and the force level during the unloading phase increased even after the temperature was changed to the initial $37^{\circ}C$. Conclusions: The results suggest that the orthodontic force level can not return to the initial force level after temperature changes. When applying superelastic nickel-titanium archwires, we must consider that a lighter force than the loading force and a heavier force than the unloading force will be applied after intraoral temperature changes caused by eating and drinking.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.

Climatic Changes and Geographical Characteristics of Solar Term Temperatures in the Korean Peninsula (한반도 절기 기온의 기후적 변화와 지리적 특성)

  • PARK, Sun-Yurp;LEE, Su-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.65-81
    • /
    • 2019
  • The twenty-four Solar Terms are Chinese traditional astronomical divisions that describe seasonal cycles of the year. Based on the analyses of meteorological data during 1979~2018, study results showed that the temperatures of the Solar Terms had increased in general in the Korean Peninsula. In North Korea, temperature increases were observed on 21 Solar Terms, and their seasonal mean temperatures were increased by $0.87^{\circ}C$, $1.19^{\circ}C$, $1.45^{\circ}C$, and $0.64^{\circ}C$ on average in spring, summer, fall, and winter, respectively. The duration of summer has lengthened due to the temperature rise in fall, and the magnitude of temperature change was greater in summer compared to winter. As for South Korea, increases in temperature were observed on 18 Solar Terms, and the temperature changes were more pronounced in fall and winter than spring and summer. The Great Snow temperature decreased more than any other Solar Terms during the study period, and this temperature change was observed both in North and South Koreas. The Great Cold, which represents the coldest day of the year, showed a significant temperature increase of $3.08^{\circ}C$, while the Slight Heat had a marginal temperature increase of $0.29^{\circ}C$. The hottest day and the first day of frost tended to come later than the Great Heat and the Frost's Decent. By contrast, the coldest day tended to occur later than the Great Cold in the study area. On average over the entire study period, the climatic fitness of the Great Heat and the Frost's Decent was higher in North Korea, and that of the Great Cold was higher in South Korea, respectively.

Study on the Latent Heat Characteristics of the Organic Compound, $C_{28}H_{58}$ and the Inorganic Compound, $CH_3COONa{\cdot}3H_2O$ (유기잠열재, $C_{28}H_{58}$과 무기잠열재, $CH_3COONa{\cdot}3H_2O$의 잠열특성연구)

  • Song, Hyun-Kap;Ryou, Young-Sun
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.53-61
    • /
    • 1991
  • In this research, Octacosane($C_{28}H_{58}$) and Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$) were selected as latent heat storage materials to store off-peak electricity or waste heat of an industrial plant. Experimental analyses were performed in terms of the variation of phase change temperature and latent heat, phase change stability for the long term utilization. The results were as follows. 1. The phase change temperatures of industrial grade Octacosane and Sodium Acetate Trihydrate were $60.7^{\circ}C$ and $57.4^{\circ}C$, the latent heat were 60.6kcal/kg and 51.1kcal/kg respectively. 2. The latent heat quantity of Octacosane was decreased with the increasing number of phase change cycles. It decreased from 60.6kcal/kg to 47.2kcal/kg upto 200 cycles and then no variation was observed after 200 cycles. 3. To prevent the supercooling of Sodium Acetate Trihydrate, the nucleating agent, Sodium Pyrophosphate Decahydrate of 3 wt% was added, and then the supercooling temperature (Tm-Tsc) was decreased from $25.7^{\circ}C$ to $1^{\circ}C$. The phase separation was disappeared by the addition of CMC-Na of 3 wt% as a thickener. It was found that the optimal quantity of nucleating agent and thickener was 4wt% considering the stability of SAT as a latent heat storage material. 4. The phase change temperature of Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$) was adjusted from 57.4 to $46.2^{\circ}C$ by the addition of UREA. And then the latent heat quantity was decreased from 51.1 to 38.3kcal/kg. 5. When the heat storage capacities between the sensible and latent heat storage materials were analyzed and compared in heating process from 30 to $90^{\circ}C$, the heat storage capacity of Octacosane was 2.45 times larger than water and 12.5 times than granite at $60.7^{\circ}C$, and the heat storage capacity of Sodium Acetate Trihydrate was 2.53 times larger than water and 12.91 times than granite at $57.4^{\circ}C$.

  • PDF

Mechanical Fatigue Lifetime of Metal Electrode for Flexible Electronics under High Temperature and High Humidity Condition (유연 전자 소자용 금속 전극의 고온/고습 조건에서 기계적 피로 수명 연구)

  • Kown, Yong-Wook;Kim, Byoung-Joon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.45-51
    • /
    • 2020
  • As flexible electronics will be used under high temperature and high humidity with repeated bending deformations, the effects of environmental condition and repeated mechanical deformations are considered simultaneously to achieve long-term reliability. In this study, the mechanical reliability of metal electrodes (Al, Ag, Cu) deposited on flexible polymer substrate is investigated under 4 different conditions: with and without repeated mechanical deformations and normal environmental or high temperature and high humidity conditions (85℃/85%). The mechanical failure does not occur in all the metal electrodes without mechanical deformation even under high temperature and high humidity conditions. The electrical resistance of metal electrode increased about 400% to 600% after 100,000 bending cycles under normal condition. For high temperature and high humidity condition, the electrical resistance of Al and Ag increased similarly. However, the resistance of Cu during bending fatigue test under high temperature and high humidity condition increased over 90000% because of the combined effect of corrosion and mechanical fatigue. This study can give a helpful information for designing electrode materials with high mechanical reliability under high temperature and high humidity.

The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test (장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구)

  • Kang, Min-Soo;Kim, Do-Seok;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • This study has been performed Thermal Shock test for analyze the cause of Power drop in PV(Photovoltaic) Module. Thermal Shock test condition was performed with temperature range from $-40^{\circ}C{\sim}85^{\circ}C$. One cycle time is 30min. which are consist of low and high temperature 15min. each other. The test was performed with total 500cycles. EL, I-V were conducted every 100cycle up to 500cycles. Mono Cell resulted in 8% Power drop rates in Bare Cell and 9% in Solar Cell. In the case of Multi Cell resulted in 6% Power drop rates in Bare Cell and 13% in Solar Cell. After Thermal Shock test, Solar Cell's Power drop resulted from surface damages, but in the case of Bare Cell's Power drop had no surface damages. Therefore, Bare Cell's Power drop was confirmed as according to leakage current increase by analysis of Fill Factor after Thermal Shock test. Also, Solar Cell's Power drop rates are higher than that of Bare Cell because of surface damages and consuming electric power increase. From now on, it should be considered that analyzed the reasons of Fill Factor decrease and irregular Power drop in PV module and Cell level using cross section, various conditions and test methods.

Electrochemical Investigation in Particle Size and Thermal Cycles of Sr Doped Layered Perovskite Based Composite Cathodes for Intermediate Temperature-operating Solid Oxide Fuel Cell (중·저온형 고체산화물 연료전지 공기극의 적용을 위한 Sr이 치환된 이중층 페로브스카이트 기반 복합공기극 물질의 분말 크기 및 열 사이클에 따른 전기화학특성 분석)

  • Kim, Jung-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.176-183
    • /
    • 2011
  • The electrochemical characteristics from various particle sizes of $Ce_{0.9}Gd_{0.1}O_{2-{\delta}}$ (CGO91) in composite cathode comprised of the samarium-strontium doped layered perovskite ($SmBa_{0.5}Sr_{0.5}Co_2O_{5+{\delta}}$) and CGO91 have been investigated for possible application as a cathode material for an intermediate temperature-operating solid oxide fuel cell (IT-SOFC). The area specific resistances (ASRs) of composite cathodes with CGO91 having smaller particle size ($0.4\sim42{\mu}m$) and SBSCO of 1 : 1 ratio (50wt% SBSCO and 50 wt% CGO91, SBSCO: 50) give the lowest ASR of $0.10{\mu}cm^2$ at $600^{\circ}C$ and $0.013{\Omega}cm^2$ at $700^{\circ}C$. However, composite cathodes with having relatively bigger CGO91 particle size show the two times higher ASR results than those of SBSCO : 50. From the 10 times thermal cycles in SBSCO : 50, the ASRs of SBSCO : 50 increased from $0.0193{\Omega}cm^2$ to $0.094{\Omega}cm^2$ at $700^{\circ}C$, however, the ASR value was maintained after 7 times of thermal cycling.

Improvement of Adhesion Strength of High Temperature Plasma Coated Aluminum Substrate with Aluminum-Alumina Powder Mixture (알루미늄 기지에 알루미늄-알루미나 혼합분말을 이용한 고온플라즈마 열분사 코팅층의 밀착강도 향상기구)

  • Park, Jin Soo;Lee, Hyo Ryong;Lee, Beom Ho;Park, Joon Sik
    • Korean Journal of Materials Research
    • /
    • v.25 no.5
    • /
    • pp.226-232
    • /
    • 2015
  • High temperature plasma coating technology has been applied to recover damaged aluminum dies from wear by spraying pure aluminum and alumina powder. However, the coated mixed powder layer composed of aluminum and alumina often undergoes a detachment from the substrate, making the coated substrate die unable to maintain its expected life span. In this study, in order to increase the bonding strength between the substrate and the coating layer, a pure aluminum layer was applied as an intermediate bond layer. In order to prepare the specimen with variable bond coating conditions, the bond coat layers with a various gun speed from 10 cm/sec to 30 cm/sec were prepared with coating cycle variations ranging from three to nine cycles. The specimen with a bond coat layer coated with a gun speed of 20 cm/sec and three coating cycles exhibited ~13MPa of adhesion strength, while the specimen without a bond coat layer showed ~6 MPa of adhesion strength. The adhesion strength with a variation of bond coat layer thickness is discussed in terms of coating parameters.

Simultaneous Determination of Pesticides in Water Using a GC/MS Coupled with Micro Extraction by Packed Sorbent (MEPS-GC/MS를 이용한 농약류 동시 수질분석)

  • Lee, Ki-chang;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.262-268
    • /
    • 2015
  • This study established an analytical method to simultaneously determine six organophosphorous pesticides [methyldemetone-S, diazinon, fenitrothion, parathion, phentoate, and O-ethyl O-(4-nitrophenyl) phenylphosphonothioate (EPN)] and carbaryl in water using a gas chromatography/mass spectrometry (GC/MS) system coupled with on-line micro extraction by packed sorbent (MEPS) and programmed temperature vaporizer (PTV) injector. Polystyrene divinylbenzene (PDVB) was used as a sorbent of MEPS. The effects of elution solvents, pH, elution volume and draw-eject cycles of samples on sample pretreatment process were investigated. Also, quality assurance and quality control (QA/QC) and the recovery of the pesticides in environmental samples were evaluated. The elution was performed using $30{\mu}L$ of a mixed solvent (acetone : dichloromethane = 80 : 20 (v/v)). Sample pretreatment processes were optimized with seven cycles of draw-eject of sample (1 mL) spiking an internal standard and sulfuric acid. At lower pH, the analytical sensitivity of diazinon decreased, but that of carbaryl increased. The method detection limit and the limit of quantification for this method were 0.02~0.18 and $0.08{\sim}0.59{\mu}g/L$, respectively. The method precision and accuracy were 1.5~11.5% and 83.3~129.8%, respectively, at concentrations of $0.5{\sim}5.0{\mu}g/L$. The recovery rates for all the pesticides except carbaryl in various environmental samples ranged 75.7~129.3%. The recovery rate of carbaryl in effluent sample was over 200% whereas carbaryl in drinking water, groundwater, and river water were in the acceptable range.