태양전지 온도 센싱만을 통한 태양광 발전시스템의 최적 운전전압에 관한 연구 (A Study on the Optimal Voltage for MPPT Obtained by only Surface's Temperature of Solar Cell)

  • Minwon Park;In-Keun Yi
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.269-275
    • /
    • 2004
  • Photovoltaic(PV) system has been studied and watched with keen interest due to a clean and renewable power source. But, the output power of PV system is not only unstable but uncontrollable, because the maximum power point tracking (MPPT) of PV system is still hard with the tracking failure under the sudden fluctuation of irradiance. Authors suggest that the optimal voltage for MPPT be obtained by only solar cell temperature. Having an eye on that the optimal voltage point of solar cell is in proportion to its panel temperature, with operating the power converter whose operating point keeps its input voltage to the optimal voltage imagined by the surface's temperature of PV panel, the maximum power point becomes tenderly possible to be tracked. In order to confirm the availability of the proposed control scheme. And both control methods are simulated not only on the various angle of sampling time of switching control, but also with the real field weather condition. As the results of that, the conversion efficiency between PV panel and converter of the proposed control scheme was much better than that of the power comparison MPPT control, and what is better, the output voltage of PV panel was extremely in stable when the optimal voltage for MPPT is obtained by only solar cell temperature.

초정밀 가공기를 위한 환경 제어용 셀에 관한 실험 및 해석적 연구 (Numerical Analysis and Experiment of Environmental Control Cell for Ultra-nano Precision Machine)

  • 오상준;김철숙;조지현;김동연;서태범;노승국;박종권
    • 한국생산제조학회지
    • /
    • 제22권5호
    • /
    • pp.824-830
    • /
    • 2013
  • In ultra-precision machining, the inside temperature should be controlled precisely. The important factors are environmental conditions (outside temperature, humidity) and temperature conditions (cutting heat, spindle heat). Thus, in this study, an environmental control cell for the ultra-precision machine that could control the inside temperature and minimize effects of the surrounding environment to achieve a thermal deformation of less than 400nm of a specimen was designed and verified through C.F.D. Further, a method that could control the temperature precisely by using a blower, heat exchanger and heater was evaluated. As a result, this study established a C.F.D technic for the environmental control cell, and the specimen temperature was controlled to be within $17.465{\pm}0.055^{\circ}C$.

실험 데이터를 사용한 자동차 $CO_2$ 냉방시스템의 제어 알고리즘 개발 (Development of Control Algorithms for a $CO_2$ Automotive Air Conditioner System by Using Experimental data)

  • 한도영;장경창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.681-686
    • /
    • 2006
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of $CO_2's$ unique propel-ties as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the effective operation of the system. In this study, dynamic models of a $CO_2$ air-conditioning system were developed by using experimental data. Control algorithms for a high-side pressure control and an indoor air temperature control were developed and analysed by using the dynamic simulation program of a $CO_2$ system.

  • PDF

중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구 (Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System)

  • 황진원;안병천
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6759-6765
    • /
    • 2015
  • 본 연구에서는 자연외기를 활용하여 건물의 중앙냉방시스템에 대한 에너지를 절약하기 위한 제어방법으로서 외기온도 조건을 고려한 나이트 퍼지제어의 적용방안에 대해 시뮬레이션 연구가 수행되었다. 외기온도의 변화특성 및 건물의 축냉성능 등이 고려되었으며, 나이트 퍼지제어를 위한 운전시작시간과 제어설정온도의 선정방안이 연구되었다. 본 연구를 위하여 TRNSYS 프로그램을 활용하여 시스템 해석 모델링을 수행하였으며, 기존 제어방식 대비 제안된 제어방법의 에너지 절약성능을 비교 분석하였다. 연구결과로 외기온도 변화에 따라 나이트 퍼지제어를 위한 운전조건을 선정한 제안된 제어방법이 기존의 나이트 퍼지제어 제어방식과 비교하였을 때는 최대 16.8%, 나이트 퍼지제어를 적용하지 않은 경우에 비해서는 최대 28.6%의 에너지 절감이 가능함을 알 수 있었다.

Identification and Multivariable Iterative Learning Control of an RTP Process for Maximum Uniformity of Wafer Temperature

  • Cho, Moon-Ki;Lee, Yong-Hee;Joo, Sang-Rae;Lee, Kwang-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2606-2611
    • /
    • 2003
  • Comprehensive study on the control system design for a RTP process has been conducted. The purpose of the control system is to maintain maximum temperature uniformity across the silicon wafer achieving precise tracking for various reference trajectories. The study has been carried out in two stages: thermal balance modeling on the basis of a semi-empirical radiation model, and optimal iterative learning controller design on the basis of a linear state space model. First, we found through steady state radiation modeling that the fourth power of wafer temperatures, lamp powers, and the fourth power of chamber wall temperature are related by an emissivity-independent linear equation. Next, for control of the MIMO system, a state space modeland LQG-based two-stage batch control technique was derived and employed to reduce the heavy computational demand in the original two-stage batch control technique. By accommodating the first result, a linear state space model for the controller design was identified between the lamp powers and the fourth power of wafer temperatures as inputs and outputs, respectively. The control system was applied to an experimental RTP equipment. As a consequence, great uniformity improvement could be attained over the entire time horizon compared to the original multi-loop PID control. In addition, controller implementation was standardized and facilitated by completely eliminating the tedious and lengthy control tuning trial.

  • PDF

자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구 (A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity)

  • 김영복;성현수;황승재;김현태;유찬석
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.

색온도 가변형 LED 조명제어시스템 (The Color Temperature Flexibility-typed LED Lighting Control System)

  • 김혜명;양우석;조영식;박대희
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.284-288
    • /
    • 2015
  • The color temperature flexibility-typed Lighting Emitting Diode(LED) lighting control system proposed in this thesis employs Pulse Width Modulation(PWM) technique to control the brightness of LED lighting. The LED lighting used as a light source has 20W downlight composed of two types of LED chips: one is Warm White and the other is Cool white. One multi-sensor module consisting an infrared sensor, an illumination sensor, and a temperature sensor was made, to which Bluetooth wireless communication technique was applied to enable a smartphone application to control lighting brightness and identify the information collected from the sensor. CS-1000, a spectroradiometer, was used to measure LED dimming control and the changing values of a color temperature in eight steps. According to a test, it was found that it was possible to change a color temperature from 3187K of Warm White LED to 5600K of Cool White LED.

PLC와 컴퓨터를 이용한 식물생산공장의 환경제어 (Environmental Control of Plant Production Factory Using Programmable Logic Controller and Computer)

  • 김동억;장유섭;김종구;김현환;이동현;장진택
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This study was conducted to develop a system and an control algorithm for control the environment of a plant factory. The greenhouse control system for environmental control was largely composed of a computer and a PLC. The screen of control program was composed of a greenhouse figure which was included machinery and equipments for greenhouse, the graph of environmental factors of inside greenhouse and the image of greenhouse. In order to reduce temperature change, the operation time of ventilation window was changed by 3 stage according to difference between a target and present temperature. When is heating, a temperature variation was shown to be $16.7{\pm}0.8^{\circ}C$. When is cooling, a temperature variation was shown to be $23.1{\pm}0.6^{\circ}C$. When is humidifing, a humidity variation was shown to be $39.3{\pm}1.6^{\circ}C$ %RH. An environmental control system and a control algorithm were proved that it was shown a good performance in a control accuracy. So a computer control system should be adapted to a control system of a greenhouse and a plant factory.

온도 제어 시스템 설계를 위한 가상 개발 기법 (Virtual Development Scheme for Temperature Control System)

  • 장유진
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5202-5207
    • /
    • 2011
  • 여러 산업 분야에서 온도 제어 시스템 설계는 매우 중요한 문제이다. 시스템 개발을 위해서는 개념적인 디자인, 실제 테스트를 위한 시스템 구현, 반복적인 실험을 통한 제어기 설계용 수식모델 도출, 제어기 설계 및 성능 테스트의 과정을 거친다. 통상적으로 실제 테스트 시스템 구현 및 반복적인 실험을 통한 모델링, 제어기 설계 및 성능 테스트에 매우 많은 시간과 비용이 소요된다. 대부분의 온도 제어 시스템 설계 문제에서 동작 온도는 복사 열전달은 무시될 수 있는 범위이며, 히터는 듀티비를 이용하여 ON/OFF 방식으로 제어된다. 본 논문에서는 이러한 조건에서 개념적인 초기 시스템 디자인 후 제어기 설계용 모델 도출에서부터 제어기 설계 및 제어성능 예측까지의 전 과정을 자동으로 수행할 수 있는 기법을 제시하여 온도 제어 시스템의 초기 설계를 손쉽고 빠르게 검증 할 수 있도록 하였다. SISO (Single Input Single Output) 시스템을 예로 들어 제안한 기법의 유용함을 보였다.

Compensation for temperature-level control of tanked water system with time delay

  • Nakamura, Masatoshi;Watanabe, Kiyoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.42-47
    • /
    • 1993
  • Importance of separation of a nonlinear dynamical system into nonlinear static part and linear dynamical part was insisted in designing a controller for the nonlinear system. We further proposed compensation techniques for oscillation of controlled variables caused by system time delay and compensation of steady state errors caused by modelling errors of the systems. The proposed principle of designing procedure and the compensation methods were discussed by applying them for temperature and level control of an actual tanked water system.

  • PDF