• Title/Summary/Keyword: temperature control circuit

Search Result 269, Processing Time 0.027 seconds

Operation and Configurgation of Superconducting Machines and Devices in Utility System (초전도전력설비의 구성 및 운전)

  • 홍원표;이원규;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.116-121
    • /
    • 1996
  • An image of future power system which has introduced superconducting generator, cable, transformer, fault current limiter, SMES and so on is presented. Conceptual designs of each SC machines and devices are carried out. The SC cable and SFCL utilize the high Tc superconductor(HTS) cooled by liquid $N_2$Other devices use low temperature superconducting cooled by He. The SC power system models are proposed detailedly. In viewpoint of the operation and control SC power system, The concrete design direction and effective role of each SC apparatus are investigated. In this paper, it is pointed that superconducting fault limiters(SFCLs) should play an important part of the quenching current level coordination to prevent the other SC devices from quenching. Finially, SFCL are also expected to he very effective to introduce flexibility of power system configuration and operation due to their possibility to enhance transient stability and reduce short circuit current.

  • PDF

Testbed Design of PWM Controlled High Voltage Relay (PWM 제어용 고전압 릴레이의 테스트베드 설계)

  • Kim, Jin-Kwang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.5
    • /
    • pp.419-424
    • /
    • 2017
  • The purpose of this study is to develop a virtual testbed capable of predicting the functional performance of a linear electromagnetic actuator for a high voltage relay in order to reduce its development costs and time. The virtual testbed is defined by a multiphysics coupling approach in order to consider the complex interactions of multi-domains such as the solenoid model of electromagnets, the mass-spring-damper model of mechanical systems, the electric circuit model for an external control unit, and the thermal model for predicting temperature variations. The performances of the existing high voltage relay were estimated by the virtual testbed, and then the effectiveness and validation of the proposed testbed were discussed in comparison with the experimental test results. This study showed that the virtual testbed can be applied in design, optimization, and investigation of high voltage relays.

LED Driver Design with Power Optimum Control Function (전력 최적제어 기능을 가진 LED 드라이버 설계)

  • Lee, Seung-Woo;Shin, Hong-Gyu;Cho, Seong-Ik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.253-256
    • /
    • 2011
  • LEDs have small size, long lifespan, high reliability, low power consumption and high color efficiency. Using such a characteristics, LED Back Light Unit has been studying actively. This paper proposes LED driver to minimize power consumption due to LED forward voltage($V_F$) difference and temperature rising. Compared to conventional LED driver, the proposed driver have excellent stability, brief structure and linear output voltage of DC-DC boost converter. Proposed LED Driver circuit was designed using 0.35um CMOS technology. And its operation was verified through simulation.

An On-line Rotor Resistance Estimator for Induction Machine Drives

  • Kwon, Chun-Ki
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.354-364
    • /
    • 2009
  • Rotor resistance variation due to changing rotor temperature is a significant issue in the design of induction motor controls. In this work, a new on-line rotor resistance estimator is proposed based on an alternate qd induction machine model which provides better mathematical representation of an induction machine than the classical qd model (which uses constant parameters). This is because the former simultaneously includes leakage saturation, magnetizing path saturation, and distributed circuit effects in the rotor conductors. The comparisons via computer simulation studies show the ability of the proposed estimator to accurately track rotor resistance variation. For the experimental studies, due to the difficulty in measuring the actual rotor resistance, comparison of the controller performance using the proposed estimator, the classical qd model based estimator, and no estimator is made.

Performance improvement of SOC indicator for electric vehicle using hydrometer (온-라인 비중계를 이용한 전기자동차용 바테리 잔존용량계의 성능개선)

  • 박종건;임영철;박철수;류영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.423-426
    • /
    • 1996
  • The conditions to be satisfied with SOC(State-of-Charge) indicator installed on the electric vehicle were that it should be used under frequent loading conditions and that it should enable the monitor to adjust to the aging effect. But, the state-of-charge test requires a lengthy stabilization period after discharge cycles and the ampere-hour test requires the knowledge of the battery capacity in terms of amp-hours. However, a monitoring technique combining the state-of-charge test to enable the monitor to adjust to the aging effect with the ampere-hour test to use under frequent loading condition is studied and implemented on a microcontroller-based circuit in this paper. Specially, optical fiber is used to realize hydrometer which is immune to electromagnetic interference and toxic environment and makes it possible to be used in a wide temperature range.

  • PDF

Analysis of Performance Test of Low-Loss Pole Transformers for distribution Line (저손실형 일단접지 주상변압기의 성능평가 분석)

  • Park, Y.C.;Kim, K.U.;Heo, J.C.;Hwang, B.K.;Roh, H.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1811-1813
    • /
    • 2001
  • In order to obtain the useful data for quality control of the pole transformer and supply the stable electric power in distribution line, The evaluation of performance for low-loss pole transformer had been performed for new products and ones under operation for several years in distribution line. As the results, we found that the rate of fail were very high in gaskette, short-circuit strength and temperature-rise test, especially 48 percent in gaskette test.

  • PDF

Design of phase tracking feedback compensator for stabilization of single mode fiber-optic Mach-Zehnder interferometer (단일모드 광섬유 Mach-Zehnder간섭계의 안정화를 위한 추적궤환 보상기의 설계)

  • 이기완;오문수;홍봉식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.547-552
    • /
    • 1989
  • Single mode optical fiber interferometeric sensors using phase tracking homodyne detection are typically susceptible to environmentally induced temperature fluctuations and other types of disturbances. In this paper compensator is described, which is a simple and effective phase tracking feedback electronic circuit must be output signal stabilized to achieve maximln sensitivity and linearity of Mach-Zehnder fiber-optic interferomter in the presence of differential phase drift. The phase tracking range of the piezoelectric cylinder in the reference arm is .+-.3.7.pi.rad, and the probe mass about 1 gram in the sensing ann was used for measurements of the gravity acceleration.

  • PDF

Development of the Boost Type Auxiliary Coach Converter (객차용 BOOST형 보조전원장치에 관한 연구)

  • 김태완;박건태;정기찬;이성목;김두식
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.727-732
    • /
    • 2000
  • This paper is on the development of a auxiliary power supply for the coach of Indian Railways. The auxiliary power supply system supplies the power for air-conditioners, air-compressors, lighting equipments, controllers, etc. It converts the input voltage, DC 110V which is supplied from battery, to AC 3${\Phi}$ 415V of 30kVA capacity. This is a low voltage-high current type converter system and largely consists of boost chopper and 3 phase inverter. Adopting a optimal control algorithm and simple power circuit, we realized the more reliable and competitive system for satisfaction of Indian Railway's strict requirement for vibration, temperature and dust. We completed the design, the manufacture and the field test of the system successfully and proved the system performance and reliability as a result of those tests.

  • PDF

The SOC, Capacity-fade, Resistance-fade Estimation Technique using Sliding Mode Observer for Hybrid Electric Vehicle Lithium Battery (하이브리드 자동차용 리튬배터리의 충전량, 용량감퇴, 저항감퇴 예측을 위한 슬라이딩 모드 관측기 설계)

  • Kim, Il-Song;Lhee, Chin-Gook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.839-844
    • /
    • 2008
  • A novel state of health estimation method for hybrid electric vehicle lithium battery using sliding mode observer has been presented. A simple R-C circuit method has been used for the lithium battery modeling for the reduced calculation time and system resources due to the simple matrix operations. The modeling errors of simple model are compensated by the sliding mode observer. The design methodology for state of health estimation using dual sliding mode observer has been presented in step by step. The structure of the proposed system is simple and easy to implement, but it shows robust control property against modeling errors and temperature variations. The convergence of proposed observer system has been proved by the Lyapunov inequality equation and the performance of system has been verified by the sequence of urban dynamometer driving schedule test. The test results show the proposed observer system has superior tracking performance with reduced calculation time under the real driving environments.

Design of Multistage Orifices for PIC System in Nuclear Reactor (원자로 압력 및 체적제어계통의 다단 오리피스 설계)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2015
  • Restriction orifices in the feed and bleed circuit of nuclear power plant are designed using computer program capable of handling multiple hole cascade orifice assembly. Single hole stages of orifice assembly are alternated with multihole stages where necessary. The distance between stages is such that it allows full pressure recovery. The minimum static pressure is higher than vapor pressure at the operating temperature so that cavitation does not occur. Piping sizes are reviewed and increased if necessary to improve rigidity.