• Title/Summary/Keyword: technical committee

Search Result 230, Processing Time 0.032 seconds

Control Efficiency for Ginseng Anthracnose by Eco-Friendly Organic Materials (유기농업자재를 이용한 인삼 탄저병의 친환경 방제효과)

  • Kim, Woo Sik;Park, Jee Sung;Ahn, In;Park, Kyung Hoon;Kim, Ki Hong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.4
    • /
    • pp.270-275
    • /
    • 2014
  • This study was conducted to select and develop effect of eco-friendly organic materials for the eco-friendly prevention of Anthracnose occurred in the ginseng. Anthracnose on ginseng is occurred by Colletotrichum gloeosporioides and the crop damage is severe especially from July to August after rainy season. The test results showed that control effect by test products materials on the three years ginseng and four years ginseng field was lower in eco-friendly organic materials than that of chemical pesticide. However, the control effect of bordeaux mixture was higher with 71.3% and 73.8% levels than those of mineral matter, microbial agent, and developed plants extract mixtures (Eugenol, Curcumin, Wood vinegar, etc). On the other hand, three types of developed plants extract mixtures (3 types) showed control effect in a range of from 58.1% to 63.6% against Anthracnose which was higher as compared with plant extract alone and sodium silicate regardless of ages of ginseng. The results of this study would attribute in verifying the control effect of eco-friendly materials against Anthracnose for ginseng through investigating antimicrobial compounds contained in the plants body. Also, it would be used as control method against Anthracnose occurred in ginseng by judging the right control time through monitoring occurrence of disease.

A study on a textbook, 'Understanding on Steel' to teach young meister of steel industry (철강산업분야 영마이스터 인력 양성 위한 '철강의 이해' 교과서 내용 선정 연구)

  • Woo, Yeoun-Jae;Kim, Ki-Soo;Lee, Chang-Hoon
    • 대한공업교육학회지
    • /
    • v.35 no.2
    • /
    • pp.112-123
    • /
    • 2010
  • This study aims at selecting contents of a text book, 'Understanding on Steel', and at presenting compilation methods of that book based on the previous researches on teaching young meister of steel industry. To do that, this, first analyzes subject profiles of textbooks on 'Understanding on Steel' to make questionnaires for the textbook compilation. Second, this study selects textbook contents improved through interviews. Third, this study revises, and complements broad contents, and selects detail units by selected professional committee which is composed of textbook researchers and editor groups. The research results are as follows: First, this study confirms that the formation of the broad contents of 'Understanding on Steel' presented in textbook profiles are appropriate, Second, this study selects subjects of detailed units along with the middle units of 'Understanding on Steel' by selecting parts needed to be improved in terms of the textbook formation. Third, this study presents the text formation system for the broad, middle and detailed units of the textbook, 'Understanding on Steel'.

  • PDF

International Standards Activities for ISO/TC 112 Vacuum Technology (ISO/TC 112 Vacuum Technology 국제표준 활동)

  • Hong, S.S.;Shin, Y.H.;Kim, J.T.;Chung, K.H.;Choi, H.K.;Kim, I.S.;Park, W.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.397-404
    • /
    • 2007
  • International Standardization for Vacuum pumps, vacuum instruments, and vacuum components has been established at ISO/TC 112 which is a technical committee of ISO (International Organization for Standardization) in the area of vacuum technology. This report shortly summarizes the structure of ISO/TC 112 and its activities on the standardization for vacuum technology. Also it introduces the brief contents of "specifications for hot cathode ionization gauges" and"Test procedure for vacuum valves" which are recently accepted as new proposals. These information on ISO/TC 112 would contribute to activate the development of vacuum technology as well as the participation for the international standardization in Korea.

Nerve conduction studies: basic principal and clinical usefulness

  • Ahn, Suk-Won;Yoon, Byung-Nam;Kim, Jee-Eun;Seok, Jin Myoung;Kim, Kwang-Kuk;Lim, Young Min;Kwon, Ki-Han;Park, Kee Duk;Suh, Bum Chun;Korean Society of Clinical Neurophysiology Education Committee
    • Annals of Clinical Neurophysiology
    • /
    • v.20 no.2
    • /
    • pp.71-78
    • /
    • 2018
  • Nerve conduction study (NCS) is an electrophysiological tool to assess the overall function of cranial and peripheral nervous system, therefore NCS has been diagnostically helpful in the identification and characterization of disorders involving nerve roots, peripheral nerves, muscle and neuromuscular junction, and are frequently accompanied by a needle Electromyography. Furthermore, NCS could provide valuable quantitative and qualitative results into neuromuscular function. Usually, motor, sensory, or mixed nerve studies can be performed with using NCS, stimulating the nerves with the recording electrodes placed over a distal muscle, a cutaneous sensory nerve, or the entire mixed nerve, respectively. And these findings of motor, sensory, and mixed nerve studies often show different and distinct patterns of specific abnormalities indicating the neuromuscular disorders. The purpose of this special article is to review the neurophysiologic usefulness of NCS, to outline the technical factors associated with the performance of NCS, and to demonstrate characteristic NCS changes in the setting of various neuromuscular conditions.

A Basic Study on Utilization of Radar Target Enhancer (능동형 레이더 리프렉터의 이용에 관한 조사연구)

  • Jeong Jung-Sik;Park Sung-Hyeon;Kim Chul-Seong;Ahn Young-sup;Kim Woo-Suk
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2004.05b
    • /
    • pp.35-38
    • /
    • 2004
  • IMO sub-committee on safety of navigation has worked a draft recommendation for RTE in order to amy a radar target enhancer(RTE) on small ships. According to the draft recommendation for RTE, we need a preliminary research for RTE development and its applicability. In this paper, we investigate the results rf field tests in other countries and analyze technical and critical problems in RTE The results of our analysis will provide helpful comments in IMO subcommmitte as well as in a domestic development of RTE.

  • PDF

A Study on the Quality Control and Operating System of Standard Reference Data(SRD) (참조표준데이터 품질관리 및 운영체계에 관한 연구)

  • Chae Kyun-shik;Lee Eung-Bong
    • Journal of Korean Library and Information Science Society
    • /
    • v.36 no.2
    • /
    • pp.283-305
    • /
    • 2005
  • Data produced during scientific and technical activities usually have value as standard reference data (SRD) which is a well-documented numeric value assessed for reliability and accuracy. The main criteria in the evaluation for SRD is how well their production is documented including a sample preparation, measurement method, data processing and so on, other than reference data. SRD is represented as a certified numeric value with uncertainty. In this study, the SRD in the area of material properties was introduced to provide understanding of SRD and its evaluation method. Also the national SRD system was studied. The national SRD system is composed of the center for the SRD, the data centers, and the committee. The role and task of those components were studied. The legislational and systematic supports for the system were proposed in this study.

  • PDF

Safety evaluation of cosmetics in Europe

  • Rogiers, Vera
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.3
    • /
    • pp.109-145
    • /
    • 2002
  • Council Directive 76/768/EEC forms the basis of the actual legislation of cosmetics in the European Union (EU). After a short introduction on the background and philosophy of this legislation, the key points will be discussed. In particular, attention will be given to the basic principles for safety and in this context the effects of the implementation of the 6th Amendment (Council Directive 93/35/EC) will be analysed. The major points for discussion will be: the safety requirements for cosmetics and the final responsibility for bringing these products on the EU market; the EU concept of safety of the finished product based on the safety of the individual ingredients; the existence of positive and negative lists of ingredients and the requirement for a European dossier for all finished products. Special attention will be given to the use of validated alternative methods and the consequences of the new proposal of a 7th Amendment. Finally, the safety evaluation as it is done by the SCCNFP (Scientific Committee on Cosmetics and Non-Food Products) in the case of an ingredient present on the positive lists and the evaluation done by a safety assessor in the case of a technical information file for a finished product, both will be discussed in detail.

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.

An overview of the structural requirements of passenger carrying rolling stock according to EN12663 and prEN15227 (EN12663과 prEN15227에 따른 객차의 구조적 요구사항 검토)

  • Ainoussa, Amar;Chang, D.S.;Paik, J.S.
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.816-823
    • /
    • 2007
  • As the South Korean rolling stock industry is developing designs for full compliance with the European Standards, it is fitting to take a look at these two core standards. The paper presents an overview of the load cases and structural requirements developed in Europe for the design of safe and compatible rolling stock vehicles. These load cases and structural requirements have been compiled into two standards namely EN12663 and EN15227. Standard EN12663 was developed as a reference design requirements standard. The work was mandated and sponsored by the European Committee for Standardization and Standard issuing National Institutions. EN12663 specifies a series of proof and fatigue load cases for European rolling stock regulations compliant vehicle designs. As EN12663 does not address the crashworthiness issue, a dedicated crashworthiness standard, EN15227, was therefore developed in a similar manner through industry wide consultations managed by a Trans-European working group of experienced engineers and specialists. In both standards, the vehicle and/or trains are grouped into categories reflecting the vehicle types and/or their indented operational function. EN15227, developed to complement EN12663, addresses the "passive" crashworthiness capability of the vehicles and trains. EN15227 specifies reference crash scenarios similar to those found in the Technical Specification for Interoperability (TSI) of high speed trains operating in Europe. The overview also touches on a general comparison with the corresponding British Group Standard (GM/RT2100) and also the UIC leaflet based load cases. The exercise is extended to pertinent design load cases specified by the Federal Railroad Administration (FRA) in the US.

  • PDF

External Quality Assessment Scheme for Biological Monitoring of Occupational Exposure to Toxic Chemicals

  • Lee, Mi-Young;Yang, Jeong-Sun;Kang, Seong-Kyu
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Objectives: In this study, we summarized the External Quality Assessment Scheme (EQAS) for the biological monitoring of occupational exposure to toxic chemicals which started in 1995 and continued until a $31^{st}$ round robin in the spring of 2010. The program was performed twice per year until 2009, and this was changed to once a year since 2010. The objective of the program is to ensure the reliability of the data related to biological monitoring from analytical laboratories. Methods: One hundred and eighteen laboratories participated in the $31^{st}$ round robin. The program offers 5 items for inorganic analysis: lead in blood, cadmium in blood, manganese in blood, cadmium in urine, and mercury in urine. It also offers 10 items for organic analysis, including hippuric acid, methylhippuric acid, mandelic acid, phenylglyoxylic acid, N-methylformamide, N-methylacetamide, trichloroacetic acid, total trichloro-compounds, trans,trans-muconic acid, and 2,5-hexanedione in urine. Target values were determined by statistical analysis using consensus values. All the data, such as chromatograms and calibration curves, were reviewed by the committee. Results: The proficiency rate was below 70% prior to the first round robin and improved to over 90% for common items, such as PbB and HA, while those for other items still remained in the range of 60-90% and need to be improved up to 90%. Conclusion: The EQAS has taken a primary role in improving the reliability of analytical data. A total quality assurance scheme is suggested, including the validation of technical documentation for the whole analytical procedure.