• 제목/요약/키워드: tapered

검색결과 909건 처리시간 0.023초

Driving Mechanism of Tapered Pistons in Bent-Axis Design Axial Piston Pumps

  • Kim, Jong-Ki;Jung, Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.181-186
    • /
    • 2003
  • In order to assure the quality of the bent axis design axial piston pumps driven by tapered pistons, it is necessary to know the characteristics of force applied to tapered pistons and the mechanism for driving the tapered pistons. Since they are able to perform both reciprocating and spinning motions in cylinder block, it is difficult to understand the driving mechanismand-tomeasure the forces applied to tapered pistons experimentally In the present study, the theoretical mechanism for driving the tapered pistons is studied by use of the geometric method. The driving area of the tapered pistons is measured by measuring the strain of a cylinder forced against a tapered piston using an electric strain gauge and a slip ring. The forces applied to tapered pistons is also investigated with the change of discharge pressure and the rotational speed. As a results of this investigation, it is concluded that the cylinder block is driven by one tapered piston in a limited area and the driving area is changed due to space angle of the tapered pistons and the swivel angle of the cylinder block. It is also observed that the force applied to tapered pistons increases as the discharge pressure and the rotational speed increase.

Rayleigh-Ritz procedure for determination of the critical load of tapered columns

  • Marques, Liliana;Da Silva, Luis Simoes;Rebelo, Carlos
    • Steel and Composite Structures
    • /
    • 제16권1호
    • /
    • pp.45-58
    • /
    • 2014
  • EC3 provides several methodologies for the stability verification of members and frames. However, when dealing with the verification of non-uniform members in general, with tapered cross-section, irregular distribution of restraints, non-linear axis, castellated, etc., several difficulties are noted. Because there are yet no guidelines to overcome any of these issues, safety verification is conservative. In recent research from the authors of this paper, an Ayrton-Perry based procedure was proposed for the flexural buckling verification of web-tapered columns. However, in order to apply this procedure, Linear Buckling Analysis (LBA) of the tapered column must be performed for determination of the critical load. Because tapered members should lead to efficient structural solutions, it is therefore of major importance to provide simple and accurate formula for determination of the critical axial force of tapered columns. In this paper, firstly, the fourth order differential equation for non-uniform columns is derived. For the particular case of simply supported web-tapered columns subject to in-plane buckling, the Rayleigh-Ritz method is applied. Finally, and followed by a numerical parametric study, a formula for determination of the critical axial force of simply supported linearly web-tapered columns buckling in plane is proposed leading to differences up to 8% relatively to the LBA model.

Active monitoring of pipeline tapered thread connection based on time reversal using piezoceramic transducers

  • Hong, Xiaobin;Song, Gangbing;Ruan, Jiaobiao;Zhang, Zhimin;Wu, Sidong;Liu, Guixiong
    • Smart Structures and Systems
    • /
    • 제18권4호
    • /
    • pp.643-662
    • /
    • 2016
  • The monitoring of structural integrity of pipeline tapered thread connections is of great significance in terms of safe operation in the industry. In order to detect effectively the loosening degree of tapered thread connection, an active sensing method using piezoceramic transducers was developed based on time reversal technique in this paper. As the piezoeramic transducers can be either as actuators or sensors to generate or detect stress waves, the energy transmission for tapered thread connection was analyzed. Subsequently, the detection principle for tapered thread connection based on time reversal was introduced. Finally, the inherent relationship between the contact area and tightness degree of tapered thread connection for the pipe structural model was investigated. Seven different contact area scenarios were tested. Each scenario was created by loosening connectors ranging from 3 turns to 4.5 turns in the right tapered threads when the contact area in the left tapered threads were 4.5 turns. The experiments were separately conducted with a highly noisy environment and various excitation signal amplitudes. The results show the focused peaks based on time reversal have the monotonously rising trend with the increase of the contact areas of tapered threads within an acceptable monitoring resolution for metal pipes. Compared with the energy method, the proposed time reversal based method to monitor tapered threads loosening demonstrates to be more robust in rejecting noise in Structural Health Monitoring (SHM) applications.

데이퍼형 마이크로 스트립 선로에서 분산과 반사가 펄스의 왜곡에 미치는 영향 (An effects of the Pulse Distortion due to Dispersion and Reflection on Tapered Microstrip Line)

  • 김기래
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(1)
    • /
    • pp.271-274
    • /
    • 2000
  • In this paper, the distortion of an electrical pulse with rise/fall time resulting from dispersion and reflection as it propagates along a tapered microstrip line is investigated, and the delay time and distortion rate with respect to input and load impedances are analyzed on triangular and exponential tapered lines and analyzed the influence of the reflection and frequency dispersion on the distorted voltage wave in the tapered lines. The observed overshoot in front of the distorted wave is caused due to the frequency dispersion and the sustained tail of that comes from the reflection in the tapered line.

  • PDF

Improvement of Communication Reliability of Small UAV by a Tapered Stacked Antenna

  • Kim, Duck-Hwan;Lee, Kyu-Hwan;Kim, Young-Sik
    • ETRI Journal
    • /
    • 제28권6호
    • /
    • pp.796-798
    • /
    • 2006
  • This letter proposes a tapered stacked microstrip antenna for application in small unmanned aerial vehicles (UAVs), which has advantages in mountainous terrains. With its tapered structure and increased bandwidth designed to operate at the resonance frequency of 2.4 GHz, the proposed antenna improves directivity, accuracy, and precision of small UAVs. The test flight results show the proposed tapered antenna has a three times higher impedance capability of 350 MHz based on VSWR<2. The transmission pattern is also more reliable than that of previous antenna designs.

  • PDF

반복하중을 받는 변단면부재의 국부좌굴 거동 (Local Buckling Behavior of Tapered Members under Cyclic Loading)

  • 이은택;김종원;박지훈;심주연
    • 한국강구조학회 논문집
    • /
    • 제18권3호
    • /
    • pp.321-329
    • /
    • 2006
  • 변단면 부재는 Amirikian(1952)에 의해 제안되어 재료 절약적 측면이나 효율적인 구조설계로 인한 경제성 확보를 목적으로 주로 단층의 장스팬 건물이나 빌딩의 켄틸레버 보에 사용되고 있다. 그러나 단면성능만을 고려하여 웨브의 춤을 설계할 때 AISC(201)에서 규정한 변단비를 넘어서거나 비콤팩트, 세장판요소로 설계되어지는 경우가 있어 이에 대한 연구가 필요한 실정이다. 따라서 본 연구에서는 변단비와 판복두께비를 주요 빈수로 한 7개의 실험체를 제작하여 반복하중을 받는 변단면 부재의 국부좌굴 특성을 살펴보았다.

경사노즐 선회분사기의 가솔린 분무 특성 (The Gasoline Spray Characteristics of Tapered Nozzle for a Swirl Injector)

  • 문석수;최재준;배충식
    • 한국분무공학회지
    • /
    • 제12권1호
    • /
    • pp.11-17
    • /
    • 2007
  • The swirl spray for direct-injection spark-ignition (DISI) engines was investigated using a nozzle whose exit surface shape was cut with a certain tapered angle. The reason for the change in spray's characteristics at various tapered angles was explained by the data correlating the taper and flow angles. The spray tended to shift its characteristics from the symmetric to asymmetric when the tapered angle was increased; furthermore, the spray penetration and spray cone angle were also increased. When the tapered angle was greater than the $90^{\circ}$ minus flow angle, an opened hollow cone spray was formed because of the fuel impingement against the tapered surface area of the nozzle exit. This behavior indicates that the reduction in the air pressure difference between the inner and outer spray of the spray can be achieved. This behavior also promises the potential use of the tapered nozzle for the case where the independence of the spray performance from atmospheric pressure and fuel temperature is desired.

  • PDF

Numerical comparison of bearing capacity of tapered pile groups using 3D FEM

  • Hataf, Nader;Shafaghat, Amin
    • Geomechanics and Engineering
    • /
    • 제9권5호
    • /
    • pp.547-567
    • /
    • 2015
  • This study investigates the behavior of group of tapered and cylindrical piles. The bearing capacities of groups of tapered and cylindrical piles are computed and compared. Modeling of group of piles in this study is conducted in sand using three-dimensional finite element software. For this purpose, total bearing capacity of each group is firstly calculated using the load-displacement curve under specific load and common techniques. Then, the model of group of piles is reloaded under this calculated capacity to find group settlements, stress states on the lateral surfaces of group block, efficiency of group and etc. In order to calculate the efficiency of each group, single tapered and cylindrical piles are modeled separately. Comparison for both tapered and cylindrical group of piles with same volume is conducted and a relation to predict tapered pile group efficiency is developed. A parametric study is also performed by changing parameters such as tapered angle, angle of internal friction of sand, dilatancy angle of soil and coefficient of lateral earth pressure to find their influences on single pile and pile group behavior.

Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns

  • Ren, Qing-Xin;Hou, Chao;Lam, Dennis;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.667-686
    • /
    • 2014
  • Tapered concrete filled double skin steel tubular (CFDST) columns have been used in China for structures such as electricity transmission towers. In practice, the bearing capacity related to the connection details on the top of the column is not fully understood. In this paper, the experimental behaviour of tapered CFDST stub columns subjected to axial partial compression is reported, sixteen specimens with top endplate and ten specimens without top endplate were tested. The test parameters included: (1) tapered angle, (2) top endplate thickness, and (3) partial compression area ratio. Test results show that the tapered CFDST stub columns under axial partial compression behaved in a ductile manner. The axial partial compressive behaviour and the failure modes of the tapered CFDST stub columns were significantly influenced by the parameters investigated. Finally, a simple formula for predicting the cross-sectional capacity of the tapered CFDST sections under axial partial compression is proposed.

방사성폐기물 처분장 감시를 위한 다발형 광섬유 센서 및 Tapered 섬광체 방사선 센서에 관한 연구 (A Study on the Bundle-type Scintillating Fiber and Tapered Scintillator Radiation Sensors for Monitoring of Radioactive Wastes Disposal Sites)

  • 김계홍;박재우
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.233-238
    • /
    • 2003
  • 플라스틱 광섬유섬광체(PSF)를 여러 가닥의 다발로 묶은 방사선센서를 제작하여 $^137Cs$ 감마선원에 적용하여 가닥수에 따른 방사선 계측 특성을 분석하였다. 이를 통하여 센서부위와 전송용 광섬유간의 집광을 용이하게 하는 끝이 가늘어지는 광섬유(Tapered fiber)의 필요성을 발견하였다. Tapered 광섬유의 성능을 예측하기 위하여 polystyrene을 기반으로 미량의 dPOPOP와 PPO 또는 dPBD를 첨가한 Tapered 플라스틱 섬광체를 제작하였으며, $^137Cs$ 선원 1 1.5, 3, 5 ${\mu}Ci$에 적용하여 출력파고 및 방사능과 총계수치 사이의 비례관계를 분석하였다. 본 연구를 통하여 플라스틱 광섬유섬광체를 Tapered 형태로 제작하는 경우 ${\mu}Ci$ 수준의 감마선 장에서 방사선 계측기로 개발될 수 있음을 확인하였다.

  • PDF