DOI QR코드

DOI QR Code

Active monitoring of pipeline tapered thread connection based on time reversal using piezoceramic transducers

  • Hong, Xiaobin (School of Mechanical and Automotive Engineering, South China University of Technology) ;
  • Song, Gangbing (Smart Material and Structure Laboratory, Department of Mechanical Engineering, University of Houston) ;
  • Ruan, Jiaobiao (Smart Material and Structure Laboratory, Department of Mechanical Engineering, University of Houston) ;
  • Zhang, Zhimin (Smart Material and Structure Laboratory, Department of Mechanical Engineering, University of Houston) ;
  • Wu, Sidong (School of Mechanical and Automotive Engineering, South China University of Technology) ;
  • Liu, Guixiong (School of Mechanical and Automotive Engineering, South China University of Technology)
  • Received : 2014.05.15
  • Accepted : 2014.10.27
  • Published : 2016.10.25

Abstract

The monitoring of structural integrity of pipeline tapered thread connections is of great significance in terms of safe operation in the industry. In order to detect effectively the loosening degree of tapered thread connection, an active sensing method using piezoceramic transducers was developed based on time reversal technique in this paper. As the piezoeramic transducers can be either as actuators or sensors to generate or detect stress waves, the energy transmission for tapered thread connection was analyzed. Subsequently, the detection principle for tapered thread connection based on time reversal was introduced. Finally, the inherent relationship between the contact area and tightness degree of tapered thread connection for the pipe structural model was investigated. Seven different contact area scenarios were tested. Each scenario was created by loosening connectors ranging from 3 turns to 4.5 turns in the right tapered threads when the contact area in the left tapered threads were 4.5 turns. The experiments were separately conducted with a highly noisy environment and various excitation signal amplitudes. The results show the focused peaks based on time reversal have the monotonously rising trend with the increase of the contact areas of tapered threads within an acceptable monitoring resolution for metal pipes. Compared with the energy method, the proposed time reversal based method to monitor tapered threads loosening demonstrates to be more robust in rejecting noise in Structural Health Monitoring (SHM) applications.

Keywords

Acknowledgement

Supported by : National Science Foundation of China

References

  1. Andrieux, S. and Leger, A. (1993), "Multiple scaling method for the calculation of threaded assemblies", Comput. Method. Appl. M., 102(3), 293-317. https://doi.org/10.1016/0045-7825(93)90052-Y
  2. Bouchoucha, F., Akrout, M., Fakhfakh, T., Ichchou, M.N. and Haddar, M. (2012), "Damage detection in cylindrical pipe through diffusion matrix in wave finite element method", Adv. Struct. Eng., 15(3), 435-445. https://doi.org/10.1260/1369-4332.15.3.435
  3. Chen, S.J., Zhang, Y., Gao, L.X., Li, Q. and An, Q. (2010), "Loading analysis on the thread teeth in cylindrical pipe thread connection", J. Press. Vessel T. -ASME, 132 (3), 1-8.
  4. Ciampa, F. and Meo, M. (2011), "Acoustic emission localization in complex dissipative anisotropic structures using a one-channel reciprocal time reversal method", J. Acoust. Soc. Am., 130(1), 168-175. https://doi.org/10.1121/1.3598458
  5. Ciampa, F. and Meo, M. (2012), "Impact detection in anisotropic materials using a time reversal approach", Struct. Health Monit., 11(1), 43-49. https://doi.org/10.1177/1475921710395815
  6. Damme, B.V., Abeele, K.V.D. and Matar, O.B. (2012), "The vibration dipole: A time reversed acoustics scheme for the experimental localisation of surface breaking cracks", Appl. Phys. Lett., 100(8), 1-3.
  7. Gangadharan, R., Murthy, C.R., Gopalakrishnan, S. and Bhat, M.R. (2009), "Time reversal technique for health monitoring of metallic structure using Lamb waves", Ultrasonics, 49(8), 696-705. https://doi.org/10.1016/j.ultras.2009.05.002
  8. He, F.J., Cui, X.M., Zhang, Y.H. and Huang, Z.Z. (2003), "Non-contact measurement of oil tube thread and the application", Proceedings of SPIE , 5058, 661-665.
  9. Hong, X.B., Wang, H., Wang, T., Liu, G.X., Li, Y.R. and Song, G.B. (2013), "Dynamic cooperative identification based on Synergetics for pipe structural health monitoring with piezoceramic transducers", Smart Mater. Struct., 22(3), 1-13.
  10. Jun, Y.J. and Lee, U. (2012), "Computer-aided hybrid time reversal process for structural health monitoring", J. Mech. Sci. Technol., 26(1), 53-61. https://doi.org/10.1007/s12206-011-1012-9
  11. Kokossalakis, G. (2006), "Acoustic data communication system for in-pipe wireless sensor networks" , Massachusetts Institute of Technology, Phd thesis, 2006.
  12. Laskar, A., Gu, H.C., Mo, Y.L. and Song, G.B. (2009), "Progressive collapse of a two-story reinforced concrete frame with embedded smart aggregates", Smart Mater. Struct., 18(7), 1-10.
  13. Li, L.Y., Song, G.B. and Ou, J.P. (2011), "DNN based fault tolerant control of nonlinear structural vibration with actuator faults", Adv. Struct. Eng., 14(5), 871-879. https://doi.org/10.1260/1369-4332.14.5.871
  14. Liao, W.I., Wang, J.X., Song, G.B., Gu, H.C., Olmi, C., Mo, Y.L., Chang, K.C. and Loh, C.H. (2011), "Structural health monitoring of concrete columns subjected to seismic excitations using piezoceramic-based sensors", Smart Mater. Struct., 20(1), 1-10.
  15. Lu, X., Lu, M.Y., Zhou, L.M., Su, Z.Q., Cheng, L., Ye, L. and Meng, G. (2011), " Evaluation of welding damage in welded tubular steel structures using guided waves and a probability-based imaging approach", Smart Mater. Struct., 20(1), 1-15.
  16. Ma, J., Lowe, M.J.S. and Simonetti, F. (2007), "Measurement of the properties of fluids inside pipes using guided longitudinal waves", IEEE T. Ultrason. Ferr., 54(3), 647-658. https://doi.org/10.1109/TUFFC.2007.288
  17. Ma,J., Lowe, M.J.S. and Simonetti, F. (2007), "Feasibility study of sludge and blockage detection inside pipes using guided torsional waves", Meas. Sci. Technol., 18(8), 2629-2641. https://doi.org/10.1088/0957-0233/18/8/039
  18. Mijarez, R., Martinez, F. and Gaydecki, P. (2009), "Continous structural health monitoring guided wave PPM system using steel pipes as communication channel for flood detection in steel offshore oilrigs", AIP Conf. Proc., 1096,1014-1021.
  19. Parka, H.W., Sohn, H., Lawc, K.H. and Farrard, C.R. (2007), "Time reversal active sensing for health monitoring of a composite plate", J. Sound Vib., 302(1), 50-66. https://doi.org/10.1016/j.jsv.2006.10.044
  20. Rezaei, D. and Taheri, F. (2010), "Health monitoring of pipeline girth weld using empirical mode decomposition", Smart Mater. Struct., 19(5), 1-18.
  21. Shahani, A.R. and Sharifi, S.M.H. (2009), "Contact stress analysis and calculation of stress concentration factors at the tool joint of a drill pipe", Mater. Design, 30(9), 3615-3621. https://doi.org/10.1016/j.matdes.2009.02.022
  22. Shi, Z.F. and Zhang, T.T. (2008), "Bending analysis of a piezoelectric curved actuator with a generally graded property for Piezoelectric parameter", Smart Mater. Struct., 17(4), 1-7.
  23. Song, G., Gu, H.C. and Mo, Y.L. (2008), "Smart aggregates: multi-functional sensors for concrete structures - a tutorial and a review", Smart Mater. Struct., 17(3), 1-17.
  24. Song, G., Gu, H.C., Mo, Y.L., Hsu T.T.C. and Dhonde, H. (2007), "Concrete structural health monitoring using embedded piezoceramic transducers", Smart Mater. Struct., 16(4), 959-968. https://doi.org/10.1088/0964-1726/16/4/003
  25. Song, G., Mo, Y.L., Otero, K. and Gu, H.C. (2006), "Health monitoring and rehabilitation of a concrete structure using intelligent materials", Smart Mater. Struct., 15(2), 309-314. https://doi.org/10.1088/0964-1726/15/2/010
  26. Tua, P.S., Quek S.T. and Wang, Q. (2005), "Detection of cracks in cylindrical pipes and plates using piezo-actuated lamb", Smart Mater. Struct., 14(6), 1325-1342. https://doi.org/10.1088/0964-1726/14/6/025
  27. Vigoureux, D. and Guyader, J.L. (2012), "A simplified time reversal method used to localize vibrations sources in a complex structure", Appl. Acoust., 73(5), 491-496. https://doi.org/10.1016/j.apacoust.2011.12.004
  28. Wang, T., Song, G., Wang, Z.G. and Li, Y.R. (2013), "Proof-of-concept study of monitoring bolt connection status using a piezoelectric based active sensing method" , Smart Mater. Struct., 22(8), 1-5.
  29. Wang, X.J., Tse,P.W., Mechefske, C.K. and Hua, M. (2010), " Experimental investigation of reflection in guided wave-based inspection for the characterization of pipeline defects" , NDT& E Int., 43(4), 365-374. https://doi.org/10.1016/j.ndteint.2010.01.002
  30. Watkins, R. and Jha, R. (2012), "A modified time reversal method for Lamb wave based diagnostics of composite structures", Mech. Syst. Signal Pr., 31(8), 345-354. https://doi.org/10.1016/j.ymssp.2012.03.007
  31. Yang, J. and Chang, F.K. (2006), " Detection of bolt loosening in C-C composite thermal protection panels: I. Diagnostic principle", Smart Mater. Struct., 15, 581-590. https://doi.org/10.1088/0964-1726/15/2/041

Cited by

  1. Multiple Cracks Detection in Pipeline Using Damage Index Matrix Based on Piezoceramic Transducer-Enabled Stress Wave Propagation vol.17, pp.8, 2017, https://doi.org/10.3390/s17081812
  2. Feasibility Study of Steel Bar Corrosion Monitoring Using a Piezoceramic Transducer Enabled Time Reversal Method vol.8, pp.11, 2018, https://doi.org/10.3390/app8112304
  3. Detection of Defects in Reinforced Concrete Structures Using Ultrasonic Nondestructive Evaluation with Piezoceramic Transducers and the Time Reversal Method vol.18, pp.12, 2018, https://doi.org/10.3390/s18124176
  4. Loosening Monitoring of a Threaded Pipe Connection Using the Electro-Mechanical Impedance Technique—Experimental and Numerical Studies vol.18, pp.11, 2018, https://doi.org/10.3390/s18113699
  5. Connection looseness detection of steel grid structures using piezoceramic transducers vol.14, pp.2, 2018, https://doi.org/10.1177/1550147718759234
  6. Loosening Monitoring of the Threaded Pipe Connection Using Time Reversal Technique and Piezoceramic Transducers vol.18, pp.7, 2018, https://doi.org/10.3390/s18072280
  7. Performance Study of FBG Hoop Strain Sensor for Pipeline Leak Detection and Localization vol.31, pp.5, 2018, https://doi.org/10.1061/(ASCE)AS.1943-5525.0000880
  8. Adaptive UKF-Based Parameter Estimation for Bouc-Wen Model of Magnetorheological Elastomer Materials vol.32, pp.1, 2019, https://doi.org/10.1061/(ASCE)AS.1943-5525.0000961
  9. Sensitivity analysis of circumferential transducer array with T(0,1) mode of pipes vol.21, pp.6, 2016, https://doi.org/10.12989/sss.2018.21.6.761
  10. Monitoring the Dynamic Response of a Buried Polyethylene Pipe to a Blast Wave: An Experimental Study vol.9, pp.8, 2016, https://doi.org/10.3390/app9081663
  11. Inspection and monitoring systems subsea pipelines: A review paper vol.19, pp.2, 2016, https://doi.org/10.1177/1475921719837718
  12. A comprehensive review of loosening detection methods for threaded fasteners vol.168, pp.None, 2016, https://doi.org/10.1016/j.ymssp.2021.108652