• Title/Summary/Keyword: tank-mix

Search Result 46, Processing Time 0.022 seconds

A Study on the Effect of Accelerated Curing on 28-Days Compressive Strength of Concrete (촉진양생이 콘크리트의 28일 압축강도에 미치는 영향에 관한 연구)

  • 최세규;유승룡;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.4
    • /
    • pp.141-148
    • /
    • 1996
  • The pulished works on Accelerated Curing Effect were generally performed around from 1960 to 1970th century for 18 to 24 hours - total curing periods. It is not possible to define the effect of temperature rise because those results were obtaine mainly by using the manually operated steam-curing tank. Thus, it may not be available to apply those data immediately on the domestic PC wall production line. The testing specimens were made from the standard mix proportion according to those of domestic PC factories to establish a basic data for the Accelerated Curing Effect. The experimental tests were conducted according to the conditions of each sub-curing periods. By comparing the results of compression tests on de-molded and 28-day water-curing specimens, we find that the most effective curing condition to obtain more than the required design strength after 28 day of water curing may be as follows: the presteaming period does not affect seriously and less than$30^{circ}C/hr$- the rate of temperature rise andless than $82^{circ}C$ - maximum temperature are necessary. It seems that post-curing procedure is very important factor to increase the effect of accelerated curing.

A Study on Constructibility of heavyweight ballast concrete with recycled iron slag (폐분철을 이용한 고중량 밸러스트 콘크리트 제조 및 시공성에 관한 연구)

  • Park, Dae-Oh;Park, Young-Shin;Park, Jae-Myung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.785-788
    • /
    • 2008
  • This study is focused on applying heavyweight concrete to ballast used to have stability of a ship. Generally, heavyweight concrete is made from a high density aggregate like magnetite or limonite. However, these materials are hard to obtain them from relevant companies and so expensive. Therefore, this study plans to product heavyweight ballast concrete which is easy to obtain by recycled iron slag. Heavyweight ballast concrete isn't required to meet some compressive strength in use, but it is required to have high flowable and 2.7t/m3 of bulk density to fill the ballast tank densely. The designed field mix proportion of concrete based on the results of pre-experiment shows it can control the temperature crack and has superior chloride corrosion resistance after conducting chloride corrosion experiment. Also, it is prefer that before airtightness voltile corrosion inhibiter(VCI) is added in airtight space of shipyard.

  • PDF

Development of a Precision BLDC Servo Position Controller for Composite Smoke Bomb Azimuth Driving System (복합연막탄 선회구동장치를 위한 정밀 BLDC 서보 위치 제어기 개발)

  • Koo, Bon-Min;Choi, Sung-Jin;Choi, Jung-Keyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.467-472
    • /
    • 2006
  • This study has been done to design a precise system and develop position control algorithm to control a Composite Smoke Bomb Azimuth driving apparatus of a BLDC servo motor. Having to Blind the sight of opposite tank. the Smoke Bomb Rotational driving system needs instant response that is able to detect opponent appearance and blast the bomb at a short time. So a design that shows fast current response capability or $300[Hz]\sim500[Hz]$ is proposed. in the MIN-MAX PWM technology is used to increase the operational speed. in order to control the blasting position, a precision position control algorithm that utilizes the integral value of speed trajectory is suggested. Also these characteristics are monitored and assessed by the PC based monitoring program which shows the graphs of current, voltage, position, and speed parameters. The main controller is based on a TMS320VC33 high performance floating-point DSP(Digital Signal Process) and the PWM generator utilizes EPM7128 CPLD.

Improvement of Herbicide Use in Crop Production. X. Interpretations in Tank - mix Use of Aciflurofen and Haloxyfop - methyl for Weeding on Late - season Cropped Soybeans (Glycine max L.) (제초제(除草劑)의 사용법(使用法) 개발(開發)을 위한 연구(硏究) - X. 만파대두(晩播大豆)의 잡초방제(雜草防除)를 위한 Acifluorfen과 Haloxyfop-methyl의 혼용효과(混用效果) 해석연구(解析硏究))

  • Guh, J.O.;Lee, K.;Kim, D.K.;Hong, S.H.
    • Korean Journal of Weed Science
    • /
    • v.5 no.1
    • /
    • pp.73-84
    • /
    • 1985
  • 25 tank-mixed combinations between Haloxyfop-methyl at 0, 0.05, 0.1, 0.15 and 0.2 kg ae/ha and Acifluorfen at 0, 0.082, 0.163, 0.245 and 0.326 kg ai/ha were applicated at post-emergence on the late-season cropped soybean(Glycine max) fields predominated by grasses and assessed on the weeding efficacy. A most abundant weed species on the experimented fields were found at September (25 species). The broadleaved weed species and sedges were successively and proportionately emerged by the control rate of grass species. From the mono-treatment of each herbicide, Haloxyfop-methyl was recognized as a highly selective one between grasses and soybean, and Acifluorfen between broadleaf weeds and soybean, respectively. By combined application with both herbicides a synergistic weeding efficacy was detected on total weed species, however antagonistic or additive on each weed groups. Among other traits of soybean, stem dry weight was influenced by weed competitions during October, number of pods per plant during August and seed yields during whole periods. For most effective and reasonable weeding, no less than 0.4 kg ai/ha of each herbicides should be applicated in combinations.

  • PDF

Status of Milk Fat Conjugated Linoleic Acid (CLA) in Selected Commercial Dairies

  • Khanal, R.C.;Dhiman, T.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.10
    • /
    • pp.1525-1538
    • /
    • 2007
  • Because of the increasing evidence of potential benefits of conjugated linoleic acid (CLA) on human health, there is a need to investigate its status in commercial dairies and develop feeding strategies to enhance the content and supply of CLA in milk and milk products. A two-year experiment was conducted to study the status of milk fat c-9, t-11 CLA on four selected commercial dairy farms in Utah (two) and Idaho (two), USA. Farms A and C grazed cows on pasture and supplemented with 7.0 kg/cow per day of their respective grain mixes during summer, while conserved forage and grain mix was fed during winter. Farm B fed a total mixed diet all year, with 10% of diet dry matter as fresh cut pasture during summer. Farm D had 1/3 of its cows grazed on pasture and supplemented with a total mixed diet during summer, while the rest were fed a total mixed diet. All cows in Farm D were fed a total mixed diet during winter. Farms A, B, C, and D had on average 80, 400, 150, and 500 milking cows, respectively, with Holstein or its crosses as the major breed. On a year-round basis, Farms A and C produced milk with 60% or more milk fat c-9, t-11 CLA and transvaccenic acid (TVA) contents than Farm B. Similarly, Farm D produced 30% or more c-9, t-11 CLA and TVA in milk than Farm B. Milk fat content of CLA and TVA was 150-200% more during summer compared with winter. Individual cows varied from 0.16 to 2.22% in milk fat c-9, t-11 CLA contents and 89% of the cows had c-9, t-11 CLA contents between 0.3 and 1.0% of milk fat. Individual cow variation was larger on Farms A and C compared with Farm D, with least variation on Farm B. Variation was larger in summer than in winter. The bulk tank milk c-9, t-11 CLA content varied from 0.27 to 1.35% of milk fat. Cows on Farms A and C produced similar or higher amounts of milk fat c-9, t-11 CLA on a daily basis even though their milk yield was lowest among the dairies. Concentration and supplies of c-9, t-11 CLA and TVA were highest from June through September and lowest from February through April, which should be the months for targeting improvement in the content and supply of milk fat c-9, t-11 CLA and TVA.

Foliar Retention of the Herbicide Pyribenzoxim(1% EC), and Its Effects on Herbicidal Activity and Rice Phytotoxicity (Pyribenzoxim 1% 유제(乳劑)의 경엽(莖葉) 부착량(附着量)과 약효(藥效), 약해(藥害)의 관계(關係))

  • Koo, Suk-Jin;Kim, Jeong-Su;Lee, Jae-Hwan
    • Korean Journal of Weed Science
    • /
    • v.18 no.4
    • /
    • pp.304-313
    • /
    • 1998
  • Foliar retention of pyribenzoxim (1% EC) was measured using the fluorescent dye rhodamine B, and related to efficacy and phytotoxicity to barnyardgarss (Echinochloa crusgalli) and rice (Oryza sativa cv. Chucheong), respectively. Effects of nozzle types (8002E flat-fan and disk-type), addition of adjuvant, variation of herbicide concentration or spray volume were compared. In barnyardgrass, foliar retention of pyribenzoxim at a recommended condition (application rate : 30g ai/ha, spray volume : 1000 L/ha) was 2.3 to 2.7 or 1.4 to $1.5{\mu}g$ ai/g fresh foliage when sprayed using the disk-type nozzle with or without adjuvant, respectively, and 0.6 to 0.7 or 0.3 to $0.5{\mu}g$ ai/g fresh foliage when sprayed using the flat-fan nozzle with or without adjuvant, respectively. The slope of increase in foliar retention was 1.0 to 1.8 when application rates increased from 10 to 60g ai/ha at 1000 L/ha, while that was 1.6 to 2.4 when spray volume increased from 330 to 2000 L/ha at $30{\mu}g$ ai/L concentration. Foliar retention of pyribenzoxim had a close relationship with herbicidal activity; regardless of spray conditions, retention to provide 90% control was about $0.8{\mu}g$ ai/g fresh foliage, and below this retention amount, efficacy decreased almost linearly. In rice, foliar retention at the recommended condition was 1.9 to 2.3 or 1.2 to $1.3{\mu}g$ ai/g fresh foliage when sprayed using the disk-type nozzle with or without adjuvant, respectively, and 0.6 to 0.9 or $0.3{\mu}g$ ai/g fresh foliage when sprayed using the flat-fan nozzle with or without adjuvant, respectively. The slope of increase in foliar retention was 1.0 to 2.8 when application rates increased from 30 to 120g ai/ha at 1000 L/ha, while that was 1.3 to 4.4 when spray volume increased from 1000 to 4000 L/ha at $30{\mu}g$ ai/L concentration. Despite the great difference in retention, rice phytotoxicity was not observed in any of these spray conditions, suggesting retention differences within 4-fold increase of application rate or spray volume do not affect rice safety. When pyribenzoxim 1EC was sprayed in tank-mix with several other commercial pesticide formulations, its retention to rice foliage tended to increase by 30 to 50%.

  • PDF