• Title/Summary/Keyword: tandem mass spectrometry #4

Search Result 282, Processing Time 0.027 seconds

Development of a method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone in dust using liquld chromatography tandem mass spectrometry (LC-MS/MS를 이용하여 먼지 속의 NNK (4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone) 정량 분석법 개발)

  • Lee, W.K.;Kang, S.J.;Oh, J.E.;Hwang, S.H.;Lee, D.H.
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a tobacco specific nitrosamine found only in tobacco products. The ability to monitor biomarker concentrations is very important in understanding environmental tobacco smoke (ETS). In this study, an efficient and sensitive method for the analysis of NNK in dust was developed and validated using liquid chromatography tandem mass spectrometry. Dust was collected with filter paper soaked in methanol. The standard solution and dust sample were diluted with 100 mM ammonium acetate and extracted using dichloromethane. Our calibration curves ranged from 25 to $10^4pg/mL$. Excellent linearity was obtained with correlation coefficient values between 0.9996 and 1.0000. The limit of detection (LOD) was 5 pg/mL ($S/N{\geq}3$) and the retention time was 10 min. The limit of quantification (LOQ) was 25 pg/mL, and the acceptance criteria was the rate of 98-103% (80-120% at levels up to $3{\times}LOQ$). The coefficient of variations (CV) was 2.8%. Accuracies determined from dust samples spiked with four different levels of NNK racurves ranged that from 25 to 104 pg/mL. Excellent linearity was obtained between 92.1% and 114%. The precision of the method was acceptable (5% of CV). The recovery rates of the whole analytical procedure at low, medium, and high levels were 105.7-116.5% for NNK. The carry-over effects during LC-MS/MS analysis were not observed for NNK. This manuscript summarizes the scientific evidence on the use of markers to measure ETS.

Comparison between the liquid-liquid partition method and modified QuEChERS method for the analysis of pesticide residues in beef fat (소지방 중 잔류농약분석을 위한 액-액분배법과 modified QuEChERS법 비교)

  • Kim, Yoen-Joo;Choi, Yoon-Hwa;Shin, Bang-Woo;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.429-439
    • /
    • 2011
  • This article described the comparison of a quick, easy, cheap, effective, rugged and safe (QuEChERS) sample preparation and the classical method established by National Veterinary Research and Quarantine Service (NVRQS) for the determination of pesticide residues in livestock products using GC-tandem mass spectrometry. The classical method by NVRQS used liquid-liquid partioning followed by evaporizing. The modified QuEChERS entailed extraction of 2 g sample with 15 ml acetonitrile containing 1% acetic acid followed by addition of 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. After centrifugation, 6 ml of the extract underwent a cleanup step (in a technique known as column-based solid phase extraction) using 400 mg each of $C_{18}$ and primary secondary amine sorbents plus 1,200 mg magnesium sulfate. The quantitation of individual pesticides by both methods was based on tissue standard calibration curves with a correlation coefficient in excess of 0.98 for the 24 pesticides. The detection limits by the classical method were ranged 1.3~5.0 ${\mu}g$/kg, with mean recoveries between 76.2% and 114.3% except aldrin (59.3%) and deltamethrin (63.6%). The detection limits by modified QuEChERS were ranged 0.3~6.2 ${\mu}g$/kg, with mean recoveries between 68.0% and 114.3% except dimethipin (152.6%), chlorfenvinphos (138.1%), 4,4-DDT (61.5%), aldrin (60.4%) and chinomethionate (30.3%).

Investigation of False Positive Rates Newborn Screening using Tandem Mass Spectrometry (TMS) Technology in Single Center (단일기관에서 이중 질량 분석법(tandem mass spectrometry technology)을 이용한 선천성 대사이상 검사의 위양성율에 대한 연구)

  • Kim, Hyunsoo;Shin, Son Moon;Ko, Sun Young;Lee, Yeon Kyung;Park, Sung Won
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • Objective: Newborn screening leads to improved treatment and disease outcomes, but false-positive newborn screening results may impact include parental stress and anxiety, perception of child as unhealthy, parent-child relationship dysfunction, and increased infant hospitalizations. The purpose of this study was to investigate of the false positive rates and the causative factors of false positive results in Tandem Mass Spectrometry (TMS) in single center. Methods: Records were reviewed for all 18,872 subjects who were born in Cheill General Hospital, during January 1st, 2012 to December 31st, 2014. 17,292 neonates (91.62%) were tested for tandem mass screening almost in 2-5th day of life. Newborn babies whose first results were abnormal had been tested repeatedly by same methods in 7-14 day. If the results were abnormal again, further evaluation was performed. TMS analysis included data for the 43 disorders screened for using TMS broken down into three categories: fatty acid oxidation disorders, organic acidurias, and aminoacidopathies. The impact of several factors on increased false positive rates was analyzed using a multivariate analysis: time from birth to sample collection, birth weight, birth height, BMI, gender, gestational age, delivery type. Results: Males of the subjects were 8942 (51.7%), female 8350 (48.3%), the mean gestational age was $38.6{\pm}1.7$ weeks, the average birth weight $3,155.6{\pm}502.4g$, the average birth height $49.1{\pm}2.9cm$, and the average BMI $13.0{\pm}3.8(kg/m^2)$. Vaginal delivery cases were 9713 (56.2%), caesarean section 7,579 (43.8%). The average date of the inspection was $2.8{\pm}1.1$ days. 224 cases were identified as TMS positive. All the subjects were false positive (222/17,292, 1.30%) except 2 cases (1 male; benign phenylketonuria and 1 female; Short chain acyl-CoA dehydrogenase deficiency). The false positive rates were 0.61% in fatty acid oxidation disorders, 0.25% in organic acidurias, and 0.45% in aminoacidopathies. In our study, the date of inspection got late, the false positive rates got higher. Because almost the cases of late test date were in treatment in neonatal intensive care unit so their test date was affected by their medical conditions. False positive rate was higher in extreme immaturity${\leq}27$ weeks than newborns of gestational age >27 weeks [OR=6.957 (CI=1.273-38.008), p<0.025] and extremely low birth weight<1,000 g than newborns of birthweight ${\geq}1,000g$ [OR=5.616 (CI=1.134-27.820), p<0.035]. Conclusion: False positive rate of TMS was 1.30% in Cheil General Hospital. Lower gestational age and birth weight impacted on increased false positive rates. Better understanding of factors that influence the reporting of screening tests, and the ability to modify these important factors, may improve the screening process and reduce the need for retesting. of screening tests, and the ability to modify these important factors, may improve the screening process and reduce the need for retesting.

  • PDF

Electrospray-Mass Spectrometric Analysis of Plasma Pyrophosphates Separated on a Multi-Modal Liquid Chromatographic Column

  • Lee, Su-Hyeon;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.92-95
    • /
    • 2011
  • Pyrophosphates are the key intermediates in the biosynthesis of isoprenoids, and their concentrations could reveal the benefits of statins in cardiovascular diseases. Quantitative analysis of five pyrophosphates, including isopentenyl pyrophosphate (IPP), dimethylallyl pyrophosphate (DMAPP), geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), and geranylgeranyl pyrophosphate (GGPP), was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative ionization mode. After dilution with methanol, samples were separated on a 3 ${\mu}m$ particle multi-modal $C_{18}$ column ($50{\times}2$ mm) and quantified within 10 min. The gradient elution consists of 10 mM ammonium bicarbonate and 0.5% triethylamine (TEA) in water and 0.1% TEA in 80% acetonitrile was used at the flow rate of 0.4 mL/min. Overall recoveries were 51.4-106.6%, while the limit of quantification was 0.05 ${\mu}g$/mL for GPP and FPP and 0.1 ${\mu}g$/mL for IPP, DMAPP, and GGPP. The precision (% CV) and accuracy (% bias) of the assay were 1.9-12.3% and 89.6-111.8%, respectively, in 0.05-10 ${\mu}g$/mL calibration ranges ($R^2$ > 0.993). The devised LC-MS/MS technique with the multi-modal $C_{18}$ column can be used to estimate the biological activity of pyrophosphates in plasma and may be applicable to cardiovascular events with cholesterol metabolism as well as the drug efficacy of statins.

Analysis of antibiotic residues in milk from healthy dairy cows treated with bovine mastitis ointment using ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry

  • Park, Eun-Kee;Ryu, Yong-Jae;Cha, Chun-Nam;Yoo, Chang-Yeul;Kim, Suk;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.233-239
    • /
    • 2016
  • This study was conducted to analyze penicillin G (PEG), streptomycin (STR) and neomycin (NEO) residues in milk of healthy lactating cows. Milk samples were collected from all four quarters of 12 dairy cows 2−7 days after intramammary infusions of an ointment containing PEG, STR and NEO once (n = 4; group I) or twice (n = 4, group II) daily. Ultra-performance liquid chromatography coupled with electrospray tandem mass spectrometry was used to determine the antibiotic residues in the samples. The correlation coefficient ($r^2$) of the calibration curves for all antibiotics was > 0.999 and the limits of detection and quantification were $0.002-0.005{\mu}g/mL$ and $0.007-0.02{\mu}g/mL$, respectively. Recovery rates were ranged from 75.5 to 92.3%. In group I, PEG, STR and NEO residues were detected in milk at 2, 3 and 2 days post-treatment, respectively, which were below the maximum residue limit (MRL). In group II, PEG, STR and NEO residues were detected in milk at 2, 3 and 3 days post-treatment, respectively, which were bellow the MRL. These results suggest that a 3-day for milk withdrawal period after the ointment treatment might be sufficient for reduction of the antibiotic residues below the MRL.

Development of an analytical method for the determination of dl-methylephedrine hydrochloride in porcine muscle using liquid chromatography-tandem mass spectrometry (LC-MS/MS를 이용한 돼지 근육조직 중 dl-methylephedrine hydrochloride의 잔류 분석법 개발)

  • Chae, Won-Seok;Kim, Suk;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.4
    • /
    • pp.209-213
    • /
    • 2020
  • This study examined the residue of dl-methylephedrine hydrochloride (MEP) on the muscle of pigs administered orally with MEP 12 g/ton feed for seven consecutive days. Twenty healthy cross swine were administered MEP. Four treated animals were selected arbitrarily to be sacrificed at 1, 2, 3, 4, and 5 days after treatment. MEP residue concentrations in the muscle were determined by liquid chromatography coupled with tandem mass spectrometry. The drug was extracted from muscle samples using 10 mM ammonium formate in acetonitrile followed by clean-up with n-hexane. The analyte was separated on an XBridgeTM hydrophilic interaction liquid chromatography column using 10 mM ammonium formate in deionized distilled water and acetonitrile. The correlation coefficient (R2) of the calibration curve was 0.9974, and the limits of detection and quantification were 0.05 and 0.15 ㎍/kg, respectively. The recoveries at three spiking levels were 94.5-101.2%, and the relative Standard Deviations was less than 4.06%. In the MEP-treated group, MEP residues on one day post-treatment were below the maximum residue limit in the muscle. The developed method is sensitive and reliable for the detection of MEP in porcine muscle tissues. Furthermore, it exhibits low quantification limits for animal-derived food products destined for human consumption.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer

  • Jaderson, Mukhtar;Park, Ju-Hyeong
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.196-204
    • /
    • 2019
  • Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted.

Comparison of sample preparation methods for quantification of febantel, an anthelmintic agent, and its metabolites in rockfish (Sebastes schlegeli) muscle using liquid chromatography-tandem mass spectrometry (LC-MS/MS를 이용한 조피볼락 근육에서 구충제 febantel 및 그 대사체들의 정량분석을 위한 시료 전처리 방법의 비교 분석)

  • Lim, Jae-Woong;Kwon, Inyeong;Kim, Taeho;Kim, Wi-Sik;Kang, So Young
    • Journal of fish pathology
    • /
    • v.34 no.2
    • /
    • pp.261-269
    • /
    • 2021
  • This study presents the evaluation of sample extraction and purification procedure for the determination of residues of febantel and its metabolites, fenbendazole, oxfendazole and oxfendazole sulfone in rockfish (Sebastes schlegeli) muscle using liquid chromatography-tandem mass spectrometry. Residues of febantel and its metabolites in rockfish muscle were analyzed using each different sample preparation method from Korean Food Standards Codex (KFSC), Food Safety and Inspection Service (FSIS, USA), and the modified FSIS method using QuEChERS kit (FSIS-Q), respectively. Each method was compared for mean recoveries and repeatabilities. Since FSIS-Q showed higher repeatabilities (coefficient of variation, CV of 2.4%~10.9%) than those of FSIS method (CV of 4.6%~17.5%), recoveries from FSIS-Q were compared with those from KFSC method. FSIS-Q showed significantly higher recoveries of 83.1%~110.1% (P < 0.05) than those from KFSC method of 64.7%~107.4%. In addition, FSIS-Q showed a good linearity over the range of 2.5~200 ㎍/kg, and excellent sensitivities with limit of detection of 0.46~0.71 ㎍/kg and limit of quantification of 1.08~2.15 ㎍/kg. Although all the sample preparation methods turned out to be able to meet CODEX guideline for all the compounds, FSIS method and FSIS-Q validated in this study could be applied to screening and quantification for residues of febantel and its metabolites in rockfish muscle with efficient preparation procedures.

Radio-Carbon Age Determination by Tandem Accelerator Mass Spectrometry Technique and Its Application To The Korean Sea (탄뎀가속기에 의한 방사성탄소 년대측정과 한국해에의 적용)

  • Suk, Bong-Chool;Toshio Nakamura;Nobuyuki Nakai;Asahiko Taira
    • The Korean Journal of Quaternary Research
    • /
    • v.4 no.1
    • /
    • pp.27-40
    • /
    • 1990
  • $^{14}C$ age dating by AMS (accelerator mass spectrometry) technique was performed on twenty five small sized fossil shells and one peat taken from the sixteen piston cores in the southern and southeastern Korean Sea. AMS technique is available to date only a few milligram of amorphous carbons compare than conventional dating technique. It is described in detail of sample pre-treatment and experimental, and applied to the reconstruction of the sea level changes since the late Pleistocene in the Korean Sea. Dated age ranges from 520$\pm$100 to older than 33,500 years. Sedimentary facies in the study area represents a different environmental set which is affected by sea level fluctuation since the late Pleistocene.

  • PDF