• Title/Summary/Keyword: tall building

Search Result 934, Processing Time 0.025 seconds

Characteristics of Negative Peak Wind Pressure acting on Tall Buildings with Step on Wall Surface

  • Yoshida, Akihito;Masuyama, Yuka;Katsumura, Akira
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.4
    • /
    • pp.283-290
    • /
    • 2019
  • Corner cut, corner chamfered or a building shape change are adopted in the design of tall buildings to achieve aerodynamic superiority as well as response reduction. Kikuchi et.al pointed out that large negative peak external pressures can appear near the inside corner of set-back low rise buildings. It is therefore necessary to pay attention to facade design around steps in building surfaces. Peak wind pressures for corner cut or corner chamfered configurations are given in the AIJ code. However, they cannot be applied where there are many variations of vertical and horizontal steps. There has been no previous systematic research on peak wind pressures around steps in building surfaces. In this study, detailed phenomenon of peak wind pressures around steps in buildings are investigated focusing on vertical and horizontal distances from the building's corner.

An Evaluation of the Dampers for the Drift Control in Resident Tall Building (초고층 주거형 건축물의 횡변위 제어를 위한 제진장치의 적용성 평가)

  • Park, Ji-Hyeong;Kim, Tae-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.499-504
    • /
    • 2008
  • Recently, the problem controlling lateral drift is important in tall buildings for improvement in economic efficiency and habitability. But, the Outrigger System, general used for tall building in Korea, has weak points with the occupancy of special space and the long duration of works. The dampers are applied to actively control building's response by earthquake and wind load in these days. Accordingly, we analyze the effect of the drift control using various dampers to substitute for the Outrigger System as the efficient system in tall buildings.

  • PDF

POD analysis of crosswind forces on a tall building with square and H-shaped cross sections

  • Cheng, L.;Lam, K.M.;Wong, S.Y.
    • Wind and Structures
    • /
    • v.21 no.1
    • /
    • pp.63-84
    • /
    • 2015
  • The shape of a tall building has significant impact on wind force generation and wind-induced dynamic response. To study the effect of recessed cavities, wind excitations on a wind-tunnel model of an H-section tall building were compared with those on a square-section building model. Characteristics of the fluctuating wind pressures on the side faces of the two tall buildings and their role in the generation of crosswind forces on the buildings were investigated with the space-time statistical tool of proper orthogonal decomposition (POD). This paper also compares the use of different pressure data sets for POD analysis in situations where pressures on two different surfaces are responsible for the generation of a wind force. The first POD mode is found to dominate the generation of crosswind excitation on the buildings.

Wind-induced lateral-torsional coupled responses of tall buildings

  • Wu, J.R.;Li, Q.S.;Tuan, Alex Y.
    • Wind and Structures
    • /
    • v.11 no.2
    • /
    • pp.153-178
    • /
    • 2008
  • Based on the empirical formulas for power spectra of generalized modal forces and local fluctuating wind forces in across-wind and torsional directions, the wind-induced lateral-torsional coupled response analysis of a representative rectangular tall building was conducted by setting various parameters such as eccentricities in centers of mass and/or rigidity and considering different torsional to lateral stiffness ratios. The eccentricity effects on the lateral-torsional coupled responses of the tall building were studied comprehensively by structural dynamic analysis. Extensive computational results indicated that the torsional responses at the geometric center of the building may be significantly affected by the eccentricities in the centers of mass and/or rigidity. Covariance responses were found to be in the same order of magnitude as the along-wind or across-wind responses in many eccentricity cases, suggesting that the lateral-torsional coupled effects on the overall wind-induced responses can not be neglected for such situations. The calculated results also demonstrated that the torsional motion contributed significantly to the total responses of rectangular tall buildings with mass and/or rigidity eccentricities. It was shown through this study that the framework presented in this paper provides a useful tool to evaluate the wind-induced lateral-torsional coupled responses of rectangular buildings, which will enable structural engineers in the preliminary design stages to assess the serviceability of tall buildings, potential structural vibration problems and the need for a detailed wind tunnel test.

The Evolution of Outrigger System in Tall Buildings

  • Ho, Goman W.M.
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.1
    • /
    • pp.21-30
    • /
    • 2016
  • The structural efficiency of tall buildings heavily depends on the lateral stiffness and resistance capacity. Among those structural systems for tall buildings, outrigger system is one of the most common and efficient systems especially for those with relatively regular floor plan. The use of outriggers in building structures can be traced back from early 50 from the concept of deep beams. With the rise of building height, deep beams become concrete walls or now in a form of at least one story high steel truss type of outriggers. Because of the widened choice in material to be adopted in outriggers, the form and even the objective of using outrigger system is also changing. In the past, outrigger systems is only used to provide additional stiffness to reduce drift and deflection. New applications for outrigger systems now move to provide additional damping to reduce wind load and acceleration, and also could be used as structural fuse to protect the building under a severe earthquake condition. Besides analysis and member design, construction issue of outrigger systems is somehow cannot be separated. Axial shortening effect between core and perimeter structure is unavoidable. This paper presents a state-of-the-art review on the outrigger system in tall buildings including development history and applications of outrigger systems in tall buildings. The concept of outrigger system, optimum topology, and design and construction consideration will also be discussed and presented.

Causes of Delay in Tall Building Projects in GCC Countries

  • Sanni-Anibire, Muizz O.;Zin, Rosli Mohamad;Olatunji, Sunday Olusanya
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.50-59
    • /
    • 2020
  • The 21st century is witnessing a rapid growth of tall buildings in urban centers globally to create more urban space for an anticipated urban population. Tall buildings, however suffer from incessant delays and sometimes total abandonment. Consequently, this study investigated and ranked the causes of delay in tall building projects, while focusing on the Gulf Cooperation Council (GCC) countries. Initially, 36 common delay causes investigated globally were categorized into 9 groups, and then further ranked utilizing the Relative Importance Index (RII) through a questionnaire survey. Tall building professionals in the GCC countries (Saudi Arabia, United Arab Emirates, Bahrain, Kuwait, Oman and Qatar) were contacted. The respondents' categories include Consultants, Contractors, and Clients' Representatives/Facility Managers. The results reveal that the top three causes include "client's cash flow problems/delays in contractor's payment", "contractor's financial difficulties", and "poor site organization and coordination between various parties". The findings from this study could help construction professionals develop guidelines and controls for delay mitigation, as well as support them in risk-based decision making in the planning of tall building projects.

  • PDF

Conjoined Towers for Livable and Sustainable Vertical Urbanism

  • Moon, Kyoung Sun;de Oliveira Miranda, Miguel Darcy
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.387-396
    • /
    • 2020
  • While tall buildings are an essential building type to accommodate an ever-growing urban population, as buildings become taller and taller, many design challenges arise. As floor spaces are repeated vertically, the occupants' natural horizontal circulation-based social interactions are limited. As buildings become ever taller, safe evacuation to the ground level becomes more challenging in emergencies. With respect to safety as well as serviceability, one of the most fundamental design challenges of exceedingly tall buildings is their structural systems that make the physical existence of tall buildings possible. While many different design solutions can be sought to resolve these issues as well as other design challenges of extremely tall buildings, this paper investigates the potential of conjoined towers to create more livable and sustainable vertical environments. Emphasis is placed on the social and structural capabilities of conjoined towers in providing enhanced social interactions and more efficient ultra-tall structures. The related brief history of conjoined towers is presented. To understand their current status, contemporary design practices of conjoined towers are discussed. Lastly, a new concept of superframed conjoined towers developed for exceedingly tall building complexes is introduced through design studies. Though envisioning future tall buildings is challenging, conjoined towers can be among the strong candidates toward more livable and sustainable vertical urbanism.

The Evaluation in Displacement Response of Tapered Tall Buildings to Wind Load (풍하중을 받는 테이퍼 고층건물의 진동변위응답 평가)

  • Cho, Ji-Eun;You, Ki-Pyo;Kim, Jong-Soo;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.4 s.18
    • /
    • pp.101-108
    • /
    • 2005
  • The investigations for mitigating wind-induced excitations of tall buildings have been carried out. The aerodynamic modification of a building shape changing the cross-section with height through tapering, which alters the flow pattern around the building, could reduce wind induced excitations of tall buildings. The fart that a tapered tall building might spread the vortex-shedding over a broad range of frequencies makes more effective for reducing acrosswind responses has been established. In this paper, to investigate the tapering effect for reducing wind-induced responses of a tapered tall building, high-frequency force-balance test was conducted. The six types of building models which have different taper ratio of 2.5%, 5%, 7.5%, 10%, 15% and one basic building model of a square cross-section were tested under the two typical boundary layers representing suburban and urban flow environment. The effect of wind direction was also considered.

  • PDF

LIFT CYCLE PREDICTION METHOD FOR THE SELECTION OF LIFT EQUIPMENT IN SUPER TALL BUILDING CONSTRUCTION

  • Seo-kyung Won;Choong-hee Han;Junbok Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.153-160
    • /
    • 2009
  • The demand for super tall building construction is increasing worldwide. There has been a constant request for achieving early payback on investment by shortening the construction time. This pertains especially for the case of huge investment projects such as super tall building construction. It is very important to shorten the construction time for the building framework, which requires substantial construction time and cost, and this is directly related to the establishment of an optimum lift plan for construction. When there is a problem in the selection of the lift equipment, it is almost impossible to revise the selection, resulting in a possible failure of the project. Thus, the purpose of this study is to analyze the function and logic for the development of the process for the selection of lift equipment for super tall building projects and further development of making the analyzed process into a system. In line with this research objective, the process of selecting the optimum lift equipment by domestic construction company was investigated and analyzed as well as collecting the actual field data. The actual data were obtained by sensors installed on tower cranes at three construction sites with the help from the construction company.

  • PDF

Prediction, Field Measurement and Compensation of Column Shortening in Tall Building (초고층건물의 기둥축소량 예측, 계측 및 보정)

  • 조석희;김한수;김도균
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.143-146
    • /
    • 2003
  • Tall Buildings have been popular in recent years. Tall buildings require special consideration to design and construction due to their structural features. Column shortening is one of the important technologies to be considered in. The long-term deformations of concrete cause vertical shortening on cores and columns, trigger deformations on cladding, partitions and finishes, and damage their serviceability. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. The main objective of this paper is to re-evaluate column shortening according to revised field information and to compare the analysis results with the actual field measurement. Mok-Dong Hyperion, a 69-story apartment building which is currently under construction, was chosen for the case study.

  • PDF