This clinical study aims to find out the effect of the fingertip's temperature and beverage-taking on the personality test by MMPI (Minnesota Multiphasic Personality Inventory). This is based on the sample survey on the 5 groups ; two or more-veined-handed group (15 persons), one-veined-handed group (22 persons), non-veined-hanede group(13 persons), beverage-taking group (41 persons) and beverage-non-taking group (14 persons). The result was obtained as follows ; 1. In the comparative examination on the two or mire-veined-haned group and the non-veined-handed group, there was significant difference of the temperature between the scale D and the scales of Mf, Pa, Pt, and Sc. 2. For the scales of Hs, D, Hy and the scales of Pd, Pa, Pt, Sc, the one-veined-handed group showed higher T-scores and lower fingertip's temperature than the non-veined-handed group without singnificant difference between them. 3. For the scales of D, Hy and the scales of Pd, Pa, Pt, Sc, the beverage-taking group showed higher T-scores and lower fingertip's temperature than the beverage-non-taking group without significant difference between them. As a result, I could find that low temperature on the fingertip, protruded vein on three knuckles(三關) of the finger and beverage-taking would cause the blood-extravasation(血瘀) and the lack of the transports in the spleen(脾不運化) and have an influence on Neurosis and Psychosis.
Proceedings of the Korean Society for Agricultural Machinery Conference
/
2000.11c
/
pp.632-638
/
2000
This paper represents the characteristics of evapotranspiration rate (EVTR) and graft-taking of watermelon grafted seedlings in a graft-taking enhancement system using fluorescent lamps as artificial lighting source. Four air temperature levels of 23, 25, 27 and 29C, three humidity levels of 85, 90 and 95%R.H. and two photosynthetic photon flux (PPF) levels of 30 and 50 ${\mu}$mol m$\^$-2/ S$\^$-1/ were provided to investigate the effects of air temperature, relative humidity and light intensity on EVTR and graft-taking of grafted seedlings. EVTR of grafted seedlings increased with increasing air temperature and the passage of time after grafting. Also EVTR increased with decreasing relative humidity. As relative humidity decreased and air temperature increased, vapor pressure deficit increased and thus EVTR increased. It is required to maintain a low level vapor pressure deficit for suppressing EVTR of grafted seedlings during first 1-2 days after grafting. Therefore, less EVTR at initial stage after grafting would be adequate for smooth joining of the scion and rootstock.
Grafting of fruit-bearing vegetables has been widely used to increase the resistance to soil-borne diseases, to increase the tolerance to low temperature or to soil salinity, to increase the plant vigor, and to extend the duration of economic harvest time. After grafting, it is important to control the environment around grafted seedlings for the robust joining of a scion and rootstock. Usually the shading materials and plastic films are used to keep the high relative humidity and low light intensity in greenhouse or tunnel. It is quite difficult to optimally control the environment for healing and acclimation of grafted seedlings under natural light. So the farmers or growers rely on their experience for the production of grafted seedling with high quality. If artificial light is used as a lighting source for graft-taking of grafted seedlings, the light intensity and photoperiod can be easily controlled. The purpose of this study was to develop a prototype system for the graft-taking enhancement of grafted seedlings using artificial lighting and to investigate the effect of air current speed on the distribution of air temperature and relative humidity in a graft-taking enhancement system. A prototype graft-taking system was consisted by polyurethane panels, air-conditioning unit, system controller and lighting unit. Three band fluorescent lamps (FL20SEX-D/18, Kumho Electric, Inc.) were used as a lighting source. Anemometer (Climomaster 6521, KANOMAX), T-type thermocouples and humidity sensors (CHS-UPS, TDK) were used to measure the air current speed, air temperature and relative humidity in a graft-taking system. In this system, air flow acted as a driving force for the diffusion of heat and water vapor. Air current speed, air temperature and relative humidity controlled by a programmable logic controller (UP750, Yokogawa Electric Co) and an inverter (MOSCON-G3, SAMSUNG) had an even distribution. Distribution of air temperature and relative humidity in a graft-taking enhancement system was fairly affected by air current speed. Air current speed higher than 0.1m/s was required to obtain the even distribution of environmental factors in this system. At low air current speed of 0.1m/s, the evapotranspiration rate of grafted seedlings would be suppressed and thus graft-taking would be enhanced. This system could be used to investigate the effects of air temperature, relative humidity, air current speed and light intensity on the evaportranspiration rate of grafted seedlings.
In Oriental medicine, Ginseng had been used for many diseases widely. It's main effects are suppling Qi and Promoting metastasis. The objective of this study is to examine the effect of Ginseng on control of body temperature. We conducted this study with 24 volunteers who had no problem in their health from November 2002 to January 2003. The body temperature were measured by DITI and thermometer before taking Ginseng and after 30minutes of the taking Ginseng extract 15g. We observed the difference of temperature among face chest and upper abdomen. All data were coded for computer analysis and significance were tested by Paired t-test and independent-t-test. According to our study, the axillary temperature show no signifiant change between two groups. The difference of temperature$({\Delta}T)$ between face and upper abdomen significantly increase after taking Ginseng extract(p<0.01). The difference of temperature$({\Delta}T)$ between face and chest significantly increase after taking Ginseng extract(p<0.05).
The decocting method of herbal medicines is various with a prescription or herbal medicine's characteristics. But it has common principles by which effective elements can be easily extracted with synergistic actions of herbs and which the therapeutic effect of a medicine is amplified. When decocting a herbal medicine, the volume of water is an important factor. Fire for decocting drugs and decocting time are also important factors. The excessive water and unproper decocting time and temperature can reduce the effect of the decoction. Besides a better decoction can be obtained by squeeze. According to herbal medicine's characteristics and prescription, there are herbs that should be treated after a specific method. For example, decoct first and decoct later. It also affects the therapeutic if a right taking method is not carried out. Methods of taking drugs include both the time and the method. We can confirm these decocting and taking methods in the ancient medical literatures of herbal medicine. This article deals with these things in detail.
This paper presents analysis of temperature and light intensity characteristics of PV modules with solar cell type. Taking the effect of sunlight irradiance on the cell temperature, the first experiment takes ambient temperature as reference input and uses the solar insolation as a unique varying parameter. Then taking the effect of the cell temperature on sunlight irradiance, the second experiment takes 1000W/$m^2$ as reference input and uses the cell temperature as a unique varying parameter. As a result, varying sunlight irradiance, the Cell-Type with the smallest change in output is HIT and the Cell-Type with the biggest change in output is a-Si. Varying the cell temperature, the Cell-Type with the smallest change in output is a-Si and the Cell-Type with the biggest change in output is Single-Si. And considering both temperature and light intensity characteristics, the Cell-Type with the smallest change in output is HIT.
The Purposes of this study are to determine differences of body temperature between Right arid left subligual areas itself and differences depending upon the utilization rate of mastication according to time intervals and to determine the length of time necessary for temperature taking. This Experiment was conducted from Oct 6 through Oct 11, 1975. in which accurately tested clinical Centigrade Thermometers have been utilized. Two thermometers were inserted simultaneously under the right and left sublingual areas and the mouth kept closed while thermometers were in Place. Temperature readings were dr no at three minutes, five minutes and ten minutes. These procedures were repeated one hundred times to different subjects and the data were analyzed statistically by means of the t-test and the F-ratio. Under the 10 hypotheses designed for this study, The findings obtained are as follows; 1. The body temperatures taken at 3, 5, 10minutes intervals in the left sublingual areas were significantly higher than in the right sublingual areas , The average differences of body temperature between the right and left sublingual areas were 0.09$^{\circ}C$, 0.05$^{\circ}C$ and 0.03$^{\circ}C$ in the oder of time interval of 3, 5, and 10 minutes. 2. The body temperatures taken in the right sublingual areas among three different temperature readings, 3, 5 and 10 minutes were significantly different in 57 subjects who have been utilizing evenly both sides of the Teeth. The average readings in a group taking for 3 minutes was 37.04$^{\circ}C$, for 5 minutes 37.15$^{\circ}C$ and for 10minutes 37.28$^{\circ}C$. 3. The body temperatures taken in the left sublingual areas among three different temperature readings, 3, 5 and 10 minutes were significantly different in 57 subjects who have been utilizing evenly both sides of the tenth. The average reading in a group taking for 3 minutes was 37.13$^{\circ}C$, for 5 minutes 37.2$^{\circ}C$ and for 10 minutes 37.31$^{\circ}C$. 4., Oral temperatures taken at 3, 5, 10 minutes intervals at the side of mouth utilized for more frequent mastication were Significantly higher than the other side. The average differences of body temperature between more frequently utilized side and Less frequently utilized side were 0.08f, 0.08f and 0.09f in the order of time interval of 3, 5 and 10 minutes. 5. Oral temperature taken at the side of mouth more frequently utilized for mastication among three different temperature readings, 3, 5 and 10 minutes were significantly different in 43 subjects who have been unequally utilizing either side of teeth. The average reading in a group taking for 3 minutes was 37.09$^{\circ}C$, for 5 minutes 37.17$^{\circ}C$ and for 10 minutes 37.3$^{\circ}C$. 6. Oral temperature taken at the side of mouth less frequently utilized for mastication among three different temperature readings 3, 5 and 10 minutes were significantly different in 43 subjects who have been unequally utilizing either side of teeth. The average reading in a group taking for 3 minutes was 37.01$^{\circ}C$, for S minutes 37.09$^{\circ}C$ and for minutes 37.21$^{\circ}C$. As a result of this study, these differences among time intervals were statistically significant, but there were not so much differences as to be considered important in the clinical practice. Therefore, there would be clinically little difference between two groups who are taking for 3 minutes and for 10 minutes.
Journal of the Korean Society of Clothing and Textiles
/
v.22
no.1
/
pp.116-126
/
1998
This study was conducted to examine the effect of difference in materials of aerobic wear on both human body's physiological reactions and subjective wearing sensation by comparing and analysing not only cotton sparidex A, B and C but nylon spandex D, E and F used as actually wearing materials. The rectal temperature of type A and I remained at high degree, the type C was higher from after high-speed running but dropped sharply when taking a break finally. Both skin temperature and mean skin temperature dropped sharply due to sweat occurred during physical exercise, and then rose slowly when taking a break. Type A -D and B-I showed that the mean skin temperature remained at high degree when wearing a cotton spandex. Type C's temperature within its aerobic wear was lower than type F while its relative humidity was higher than type F. Wearing sensation showed a change similar to wearing, particularly, which was remarkable in type B-E. Also, it was shown that humidity sensation, tactile sensation and comfort sensation were good when wearing the cotton spandex.
To develop an automatic detecting system of body temperature of dairy cattle while milking, measurement of the temperature of mammary skin using three thermometers attached into the lining of teat cup was carried out for 23 dairy cattle, whereas measurement of the temperature of milk while milking was also performed for 263 animals. For the latter experiment, three thermometers were attached at 10cm(left and right) and 20 cm away from an individual milk collector on the milk transporting hose. Taking the rectal temperature was accompanied all the time for the experiments. The measurement of the temperature of mammary skin using teat cup was successful for 11 of 23 dairy cattle(47.8%) and the mean temperature was $33.5^{\circ}C$ with the mean difference of $5.2^{\circ}C$ from the mean rectal temperature. The measurement of the temperature of milk using the thermometers onto the milk transporting hose while milking was very successful , From 37.3 to $38.4^{\circ}C$ of rectal temperature, the temperature of milk was almost the same and from 38.5 to $39.5^{\circ}C$ of rectal temperature, the temperature of milk tended to be low with the difference of 0.1$^{\circ}C$. From 39.6 to $41^{\circ}C$ of rectal temperature, the temperature of milk tended to be low with the difference of $0.2-0.6^{\circ}C$. These results indicated that automatic detection of body temperature whether low or high can be possible if the temperature of milk is taken while milking and if it is connected to the integration system by on-line.
Yong Hyeon Kim;Chul Soo Kim;Ji Won Lee;Sang Gyu Lee
Journal of Bio-Environment Control
/
v.10
no.4
/
pp.232-236
/
2001
Four air temperature levels of 23, 25, 27 and 29$^{\circ}C$, three humidity levels of 85, 90 and 95% R.H. at photosynthetic photon flux (PPF) of 50 $\mu$mol.m$^{-2}$ .s$^{-1}$ were provided to investigate the effect of vapor pressure deficit on the evapotranspiration rate (EVTR) and graft-taking of watermelon grafted seed-increase. Thus EVTR of grafted seedlings increased with increasing air temperature at high humidity of 95%R.H. At relatively low humidity of 85% R.H., grafted seedlings showed a high EVTR and some wilting of scions was observed at this condition. This result would be ascribed to the low supply of water to vascular bundles according to the insufficient joining of scions and rootstocks. Differences in EVTR between 90% R.H. and 95% R.H. were not observed. Grafted seedlings showed high graft-taking at high relative humidity. Relative humidity had highly influenced to the graft-taking as compared to the air temperature. Graft-taking increased with decreasing vapor pressure deficit. Graft-taking greater than 90% was found at vapor pressure deficit less than 0.4kPa which could be obtained at humidity higher than 90% R.H. Therefore it is required to control the humidity higher than 90% R.H. for suppressing EVTR of grafted seedlings and preventing some wilting of scoins and thus enhancing the graft-taking of grafted seedlings.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.