• Title/Summary/Keyword: tag open-cup tester

Search Result 28, Processing Time 0.029 seconds

Investigation of Reliability of Flash Points and Autoignition Temperatures of Acids (산류(Acids)의 인화점과 최소자연발화온도의 신뢰성 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.42-47
    • /
    • 2009
  • The flash point and the AIT(auto-ignition temperature) are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. In order to know the accuracy of data in MSDS(Material Safety Data Sheet), the flash point of n-acids were measured by using Pensky-Martens closed cup tester(ASTM D93), Setaflash closed cup tester(ASTM D3278), Tag open cup tester(ASTM D1310) and Cleveland open cup tester(ASTM D92). Also, the AIT of n-acids were measured by using ASTM E659-78 tester. The measured the flash points and the AIT were compared with literatures and MSDS in KOSHA. The measured the flash points and the AIT were different from those in literatures and MSDS. Therefore, This paper shows that it is needed to investigate the MSDS compatibility of n-acids for the fire safety objectives.

Measurement of Flash Points and Autoignition Temperatures for Xylene Isomers (크실렌 이성질체의 인화점과 최소자연발화온도의 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.4
    • /
    • pp.40-45
    • /
    • 2009
  • In order to investigate the compatibility of data in MSDS(Material Safety Data Sheet), the flash point of xylene isomer was measured by using Pensky-Martens closed cup (ASTM D93), Setaflash closed cup(ASTM D3278), Tag open cup(ASTM D1310), and Cleveland open cup (ASTM D92) testers. Also, the AITs(autoignition temperatures) of xylene isomers were measured by using ASTM E659-78 tester. The measured the flash points and the AITs were compared with literatures and MSDS in KOSHA(Korea Occupational Safety and Health Agency). The measured the flash points and the AITs were different from those in literatures and MSDS. As a result, this paper is shown that it is needed to investigate combustion characteristics of xylene isomer for the fire safety objectives.

  • PDF

Measurement and Prediction of Fire and Explosion Characteristics of n-Butylacetate (초산부틸의 화재 및 폭발 특성치 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.25-31
    • /
    • 2017
  • The flash point, explosion limits, autoignition temperature(AIT) are important combustible properties which need special concern in the chemical safety process that handle hazardous substances. For the evaluation of the flammable properties of n-butylacetate, this study was investigated the explosion limits of n-butylacetate in the reference data. The flash points, fire points and AIT by the ignition delay time of n-butylacetate were experimented. The lower flash points of n-butylacetate by using the Setaflash and Pensky-Martens closed-cup testers were $24^{\circ}C$ and $26^{\circ}C$, respectively. The flash points of n-butylacetate using the Tag and Cleveland open cup testers are measured $31^{\circ}C$ and $40^{\circ}C$, respectively. And the fire points of n-butylacetate by the Tag and Cleveland open cup testers were measured $32^{\circ}C$ and $41^{\circ}C$. The AIT of n-butylacetate measured by the ASTM 659E tester was measured as $411^{\circ}C$. The lower explosion limit of lower flash point $24^{\circ}C$, which was measured by the Setaflash tester, was calculated to be 1.40 vol%. Also, the upper explosion limit of upper flash point $67^{\circ}C$ the Setaflash tester was calculated to be 12.5 vol%.

The Measurement of Lower Flash Point for tert-Pentanol+n-Decane System Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 tert-Pentanol+n-Decane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.41-46
    • /
    • 2012
  • The flash point the lowest temperature at which the concentration of vapor of the substance in the air reaches the lower flammability limit(LFL), and is one of the most important physical properties used to determine the potential for fire and explosion hazards of industrial materials. The most published flash point data was for pure components and the flash points of the binary solutions that have flammable components, appear to be scarce in the literature. In the present study, the flash points of tert-pentanol+n-decane system were measured by Tag open-cup tester. The measured data were compared with the values calculated by the Raoult's law and the optimization methods based on the Wilson and NRTL equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

The Measurement and Estimation of Minimum Flash Point Behavior for Binary Mixtures Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 이성분계 혼합물의 최소인화점 현상의 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.50-55
    • /
    • 2008
  • The flash points for the systems, ethlybenzene+n-butanol and ethlybenzene+n-hexanol, were measured by using Tag open-cup tester (ASTM D1310-86). These binary mixtures exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The experimental data were compared with the values calculated by the Raoult's law, the UNIQUAC equation and the NRTL equation. The calculated values based on the UNIQUAC and NRTL equations were found to be better than those based on the Raoult's law. It was concluded that the UNIQUAC and NRTL equations were more effective than the Raoult' law at describing the activity coefficients for nonideal solution such as the ethlybenzene+n-butanol and ethlybenzene+n-hexanol systems. And the predictive curve of the flash point prediction model based on the NRTL equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the UNIQUAC equation.

  • PDF

The Measurement and Estimation of Lower Flash Point for o-Xylene+n-Pentanol and m-Xylene+n-Hexanol Systems Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 o-Xylene+n-Pentanol 계와 m-Xylene+n-Hexanol 계의 하부인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin;Jeong, Kee-Sin
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.19-25
    • /
    • 2010
  • The flash points for the systems, o-xylene+n-pentanol and m-xylene+n-hexanol, were measured by using Tag open-cup tester(ASTM D1310-86). The experimental data were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law. The predictive curve of the flash point prediction model based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the Wilson equation.

The Measurement of Flash Point for Unflammable-Flammable Binary Mixtures(CCl4+o-Xylene and CCl4+p-Xylene) Using Open Cup Tester (개방식 장치를 이용한 난연성-가연성 이성분계 혼합물(CCl4+o-Xylene and CCl4+p-Xylene)의 인화점 측정)

  • Kim, Chang-Seob;Lee, Sungjin;Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.18-23
    • /
    • 2015
  • The flash point is used to categorize inflammable liquids according to their relative flammability. The flash point is important for the safe handling, storage, and transportation of inflammable liquids. The flash point temperature of two binary liquid mixtures($CCl_4+o-xylene$ and $CCl_4+p-xylene$) has been measured for the entire concentration range using Tag open cup tester. The flash point temperature was estimated using Raoult's law, UNIQUAC model and empirical equation. The experimentally derived flash point was also compared with the predicted flash point. The empirical equation is able to estimate the flash point fairly well for $CCl_4+o-xylene$ and $CCl_4+p-xylene$ mixture.

The Measurement of Combustible Properties of Acetic Anhydride for the Compatibility of MSDS (MSDS 적정성을 위한 아세틱안하이드리드의 연소특성치 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.85-90
    • /
    • 2014
  • For the safe handling of acetic anhydride, this study was investigated the explosion limits of acetic anhydride in the reference data. And the lower flash points, upper flash points, and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower and upper explosion limits of acetic anhydride by the investigation of the literatures recommended 2.9 Vol% and 10.3 Vol.%, respectively. The lower flash point of acetic anhydride by using Setaflash closed-cup tester was experimented $49^{\circ}C$. The lower flash point acetic anhydride by using Tag and Cleveland open cup tester were experimented $55^{\circ}C$and $62^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for acetic anhydride. The experimental AIT of acetic anhydride was $350^{\circ}C$.

Measurement and Prediction of Combustuion Properties of di-n-Buthylamine (디노말부틸아민의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.42-47
    • /
    • 2019
  • In this study, combustion characteristics were measured by selecting di-n-buthylamine, which is widely used as an emulsifier, insecticide, additive, rubber vulcanization accelerator, corrosion inhibitor, and raw material for dye production. The flash point of the di-n-buthylamine was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of the di-n-buthylamine was measured by ASTM 659E. The explosion limits of the di-n-buthylamine was calculated using the measured flash points by Setaflash tester. The flash point of the di-n-buthylamine by using Setaflash and Pensky-Martens closed-cup testers were experimented at 38 ℃ and 43 ℃, respectively. The flash points of the di-n-buthylamine by Tag and Cleveland open cup testers were experimented at 48 ℃. The AIT of the di-n-buthylamine was experimented at 247 ℃. The LEL and UEL calculated by using lower and upper flash points of Setaflash tester were calculated at 0.69 vol% and 7.7 vol%, respectively. The measurement of the flash point measurement and the calculation method of the explosion limit prediction presented in this study can be used to study the fire and explosion characteristics of the other combustible liquids.

Combustion Property of Biodiesel Fuel (바이오디젤 연료의 연소 특성)

  • Song, Young-Ho;Shin, Baeg-Woo;Ha, Dong-Myeong;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2009
  • As the environmental pollution by the drastic increase of vehicles becomes one of the social major concerns, the method of reducing the harmful exhaust emission is being the subject of interest. Utilization of waste edible oil as a raw material for biodiesel production is helpful not only for the stable supply of raw materials but also costing down the biodiesel price. This study was conducted to examine the combustion and thermal characteristics with mixing ratio of biodiesel fuel. Flash points, fire points and autoignition temperature (AIT) were measured by using Tag closed cup, Cleveland open cup flash point tester and AIT apparatus. As the result, flash points, fire points and AIT increased with percentage of more contained biodiesel.