• Title/Summary/Keyword: t-Test

Search Result 23,835, Processing Time 0.059 seconds

A Study on DNA Polymorphism of the Bovine c-KIT Receptor Gene (소 c-KIT Receptor 유전자의 다형성에 관한 연구)

  • Jang, Y.S.;Kim, T.H.;Yoon, D.H.;Park, E.W.;Lee, H.W.;Lee, H.K.;Cheong, I.C.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.653-660
    • /
    • 2002
  • We considered KIT gene as a candidate gene for the white-spotting pattern in cattle. This study was carried out to detect genetic variation of c-KIT receptor gene and to investigate association between the mutation and the white-spotting pattern in cattle. PCR-RFLP analysis within intron 6 of c-KIT receptor gene were performed with 8 cattle breeds including Hanwoo, Angus, Brown Swiss, Charolais, Hereford, Holstein, Limousin and Simmental. When PCR product of approximately 2,440 bp including intron 6 of c-KIT receptor gene was sequenced, four nucleotide substitutions were found within intron 6 of the bovine c-KIT receptor gene. In PCR-RFLP analysis, three alleles (A, B and C), two alleles (A and B) and two alleles (A and B) at each locus were identified by MspⅠ, BsrBⅠ and NdeⅠ, respectively. Although frequencies of allele at each locus were different among cattle breeds, we could not get any evidence related with white or white spotting phenotypes in these mutations on intron 6 of c-KIT receptor gene. However, we can not entirely exclude the possibility that c-KIT receptor gene is responsible for white spotting phenotype in cattle. Thus, further studies need to detect other mutations in c-KIT receptor gene and to test association of those mutations and coat color phenotypes in cattle.

Result of Radiation Therapy of Cerebellar Medulloblastoma - with Emphasis on the Neuraxis Dose - (전중추신경계 조사선량을 중심으로 한 수아세포종의 방사선치료성적)

  • Kim Joo Young;Kim Il Han;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.69-77
    • /
    • 1993
  • Treatment of cerebellar medulloblastoma has been much improved with modern surgical technique for gross total tumor removal and adequate radiation therapy for the whole craniospinal axis. Questions have been arosen about the optimal radiation dose for the preventive treatment of whole cranium and whole spinal axis. Recently, many authors have reported their treatment results as comparable to older data, using lower than conventional dose of 3,600 cGy-4,000 cGy. For 50 patients treated between 1981 and 1990 at the Department of Radiation Therapy of SNUH, retrospective analysis was done for the treatment result, especially the neuraxis control, by radiation dose for the presymptomatic area of the disease. Analysis only by total spinal dose did not give any significant difference. But further analysis by following patient group; 3,600 cGy/150 cGy (n=6), 3,000 cGy/150 cGy (n=10), 2,400 cGy/150 cGy (n=17) and 2,400 cGy/100-120 cGy (n=11) showed significant improvement of neuraxis control by decreasing order (p =0.003). There was no significant difference in overall survival between the groups. For the 19 patients who had been confirmed initially as having no neuraxis disease, TDF 30 was the cur-off value that could prevent neuraxis failure (p =0.004). We couldn't define any TDF value that give reasonable control for the patient group with positive CSF study at initial diagnosis.

  • PDF

The Effect of Pentoxifylline on Radiation-Induced Cardiac Injury in ICR Mice (방사선조사후 발생한 심장손상에서 Pentoxifylline 이 미치는 효과)

  • Suh Hyun Suk;Yang Kwang Mo;Kang Seung Hee;Kang Yun Kyung
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.281-290
    • /
    • 1996
  • Purpose : Chest irradiation leads to a significant cardiac injury in a number of patients. To prevent, or to reduce the risk of radiation-induced cardiac injury, pentoxifylline(PTX), a haemorrheologic agent that improves the blood flow through small blood capillaries has been employed. Materials and Methods : One hundred and eighty ICR mice were divided into three study groups: control, radiation alone, and radiation-pentoxifylline. Each group was subdivided into 12 subgroups: 1 3, 6 and 10 days and 2, 3, 4, 6, 8, 12, 16 and 20 weeks by observation Period after irradiation. The total 15Gy of radiation was delivered in a single fraction through anterior mediastinal port. Pentoxifylline was injected subcutaneously daily 50mg/kg to the back of the mice from the first day of irradiation throughout the observation period. The mice of each group after a certain observation period were sacrificed and sectioned for histopathologic examination of the heart. Result : The findings of acute radiation-induced carditis i.e., heterophilic infiltration and vacuolization and ballooning of endothelial cells were observed upto 6 weeks and reduced sharply afterwards. The late radiation effects including pericarditis with mononuclear cell infiltration, pericardial fibrosis, endothelial cell changes, myocardial degeneration and fibrosis present from 4 weeks onwards after irradiation but with various degree of severity. The overall process of pathologic changes of radiation-pentoxifylline group was similar to those of radiation alone group but the duration of acute stage was relatively short and the severity of late cardiac toxicity was much lesser compared with those of radiation alone group. Conclusion : Pentoxifylline can effectively reduce the late radiation-induced cardiac injury and reslve the acute effects relatively rapidly.

  • PDF

Analysis on the Degree of Cerebral Activity According to Cognition Task in Welders Exposed to Manganese (망간 노출 용접공의 인지수행에 따른 뇌 활성화 정도 분석)

  • Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • In this study, we examined the impact caused by chronic exposure to Mn by investigating the degree of brain activation based on the data of recognition activities using fMRI (functional magnetic resonance imaging). A questionnaire survey, blood tests, and fMRI tests were carried out with respect to two groups. Group 1 was an exposure group consisting of 15 male workers who are 34 years old or older, and who worked for longer than 10 years in a shipbuilding factory as a welder. Group 2 was a control group consisting of 15 workers in manufacturing industries with the same gender and age. The results showed that blood Mn concentration of Group 1($1.3\;{\mu}g/dl$) was significantly higher than that of Group 2($0.8\;{\mu}g/dl$)(p < 0.001), and Pallidal Index (PI) of Group 1 was also significantly higher than that of Group 2 (p < 0.001). PI value of the group whose blood Mn concentration was $0.93\;{\mu}g/dl$ or higher was significantly higher than that of the group whose blood Mn concentration was less than $0.93 \;{\mu}g/dl$ (p < 0.001). As for brain activity area within the control group, the right and the left areas of occipital cortex showed significant activity and the left area of middle temporal cortex, the right area of superior inferior frontal cortex and inferior parietal cortex showed significant activity. Unlike the control group, the exposure group showed significant activity on the right area of superior inferior temporal cortex, the left of insula area. In the comparison of brain activity areas between the two groups, the exposure group showed significantly higher activation than the control group in such areas as the right inferior temporal cortex, the left area of superior parietal cortex and occipital cortex, and cerebellum including middle temporal cortex. However, in nowhere the control group showed more activated area than the exposure group. As the final outcome, chronic exposure to Mn increased brain activity during implementation of arithmetic task. In an identical task, activation increased in superior inferior temporal cortex, and insula area. And it was discovered that brain activity increase in temporal area and occipital area was more pronounced in the exposure group than in the control group. This result suggests that chronic exposure to Mn in the work environment affects brain activation neuro-network.

Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease (Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계)

  • Cho, Jung-Ah;Choi, Chung-Il;Kwak, Dong-Suk;Kim, Jeong-Gyun;Bae, Sun-Kun;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Kang, Seung-Wan;Woo, Eon-Jo;Kim, Sin-Woo;Sohn, Sang-Kyun;Chae, Shung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Health Assessment of Shift Workers in a Automobile Manufacturing Plant (자동차공장 교대작업 근로자들의 건강상태평가)

  • Lee, Jung-Jeung;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.103-121
    • /
    • 1995
  • An investigation on psychophysiological health and social well-being of shift workers been carried out on workers of a automobile manufacturing plant in Ulsan, for 1 month from April, 1993. This cross-sectional survey compared shift workers(n=544) with day workers(n=115). Each subject completed a questionnaire about his personal habit, background, shift schedule, sleep and eating patterns, subjective digestive symptom and psychological well-being and distress using the General Well-Being Schedule(GWB) by self administrated questionnaire that was developed for the U.S. Health and Nutrition Examination Surveys (HANES I). Chi-square analysis was used for discontinuous data and the t-test was used for continous data to determine whether differences noted between the two groups. In terms of sleep quality, a greater percentage of shift workers frequently had trouble getting back to sleep once awakend(p<0.01), and a greater percentage of shift workers awakend tired or sleepy frequently more often than day workers(p<0.05). In rating the quality of their sleep, more shift workers rated their sleep fair to poor than day workers, and greater percentage of shift workers felt tired or sleepy at work two or more times per week(p<0.01) and a much higher percentage of shift workers felt tired or sleepy after work every days(p<0.01). In terms of sleep patterns, a much higher percentage of day workers reported uninterrupted sleep per 24hours than shift workers. The shift workers reported different eating patterns from day workers but there were no statistically significant and rate of their appetite. Thirteen percent of day workers reported the best appetite but only 6.6% of shift workers had the best appetite. The gastric complaints is more frequent in shift workers than day workers(p<0.01). Among subscores in General Well-Being Schedule, anxiety, depression, positive well-being and vitality subscale of shift workers were lower than those of day workers(p<0.05) and general health and self control subscale of shift workers were lower than .those of day workers but there were no statistical significant difference. Based on these study result, it could be concluded that the shift work has significant effects on some psychophysiological conditions of the workers.

  • PDF

Morphometric Study on the Arterial Palmar Arch of the Hand (손바닥 동맥활에 관한 형태계측 연구)

  • Park, Bong Kwon;Jang, Soo Won;Choi, Seung Suk;Ahn, Hee Chang
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.691-701
    • /
    • 2009
  • Purpose: Deviations of arterial palmar arches in the hand can be explained on the embryological basis. The purpose of this study was to provide new information about palmar arches through cadaver's dissection. The values of the location and diameter in these vessels were analyzed in order to support anatomical research and clinical correlation in the hand. Methods: The present report is based on an analysis of dissections of fifty - three hands carried out in the laboratory of gross anatomy. A reference line was established on the distal wrist crease to serve as the X coordinate and a perpendicular line drawn through the midpoint between middle and ring fingers, which served as the Y coordinate. The coordinates of the x and y values were measured by a digimatic caliper, and statistically analyzed with Student's t - test. Results: Complete superficial palmar archs were seen in 96.2 % of specimens. In the most common type of males, the superficial arch was formed only by the ulnar artery. In the most common type of females, the superficial arch was formed anastomosis between the radial artery and the ulnar artery. The average length of the superficial and deep palmar arch is $110.3{\pm}33.0mm$ and $67.9{\pm}14.0mm$ respectively. Regarding the superficial palmar arch, ulnar artery starts $-16.1{\pm}5.1mm$ on X - line, and $2.5{\pm}24.5mm$ on Y - line. Radial artery appears on palmar side $7.7{\pm}3.2mm$ on X - line, and $20.9{\pm}10.9mm$ on Y - line. But radial artery starts on $6.3{\pm}3.6mm$ on X - line, and $3.4{\pm}5.1mm$ on Y - line. Digital arteries of superficial palmar arch starts on $6.1{\pm}3.7mm$, $33.9{\pm}8.8mm$ on index finger, $1.8{\pm}3.4mm$, $40.1{\pm}7.3mm$ on middle finger, $-3.2{\pm}4.9mm$, $42.6{\pm}7.0mm$ on ring finger, and $-8.9{\pm}5.1mm$, $42.5{\pm}80mm$ on little finger in respective X and Y coordinates. Radial artery of deep palmar arches measured at the palmar side perforating from the dorsum of hand. It's coordinates were $9.7{\pm}4.8mm$ on X - line, $21.7{\pm}10.2mm$ on Y - line. Ulnar artery was measured at hypothenar area, and it's coordinates were $-20.4{\pm}6.3mm$ on X - line, and $30.6{\pm}7.4mm$ on Y - line. Conclusions: Anatomically superficial palmar arch can be divided into a complete and an incomplete type. Each of them can be subdivided into 4 types. The deep palmar arch is less variable than the superficial palmar arch. We believe these values of the study will be used for the vascular surgery of the hand using the endoscope and robot in the future.