• Title/Summary/Keyword: t Distribution

Search Result 4,333, Processing Time 0.028 seconds

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

Extreme Value of Moving Average Processes with Negative Binomial Noise Distribution

  • Park, You-Sung
    • Journal of the Korean Statistical Society
    • /
    • v.21 no.2
    • /
    • pp.167-177
    • /
    • 1992
  • In this paper, we investigate the limiting distribution of $M_n = max (X_1, X-2, \cdots, X_n)$ in the infinite moving average process ${X_t = \sum c_i Z_{t-i}}$ generated from i.i.d. negative binomial variables $Z_i$'s. While no limit result is possible, nonetheless asymptotic bounds are derived. We also present the tail behavior of $X_t$, i.e., weighted sum of i.i.d. random variables. This continues a study made by Rootzen (1986) for discrete innovation sequences.

  • PDF

Finite Element Analysis of SMC Compression Molding Processes (SMC 압축성형 공정에 관한 유한요소해석)

  • Lee, Choong-Ho;Huh, Hoon
    • Transactions of Materials Processing
    • /
    • v.4 no.3
    • /
    • pp.204-213
    • /
    • 1995
  • A finite element program is developed to analyze the flow phenomena in SMC compression molding as a viscoplastic model. The calculation of temperature distribution is also carried out by uncoupling the thermal analysis from the flow analysis. SMC molding processes with a flat plate substructure and the one with a T-shaped rib are considered in numerical simulation. The numerical results provide deformed shapes, temperature distribution in a SMC charge, and the forming load. The simulation of compression molding of a flat plate with a T-shaped rib requires a remeshing technique for the whole process.

  • PDF

Stochastic Comparisons of Order Statistics

  • Kim, Song-Ho
    • Journal of the Korean Statistical Society
    • /
    • v.22 no.1
    • /
    • pp.13-25
    • /
    • 1993
  • The purpose of this paper is to investigate the properties of order statistics under various stochastic relations. We study the stochastic comparison of order statistics in a single sample. And we consider two sample case too. For example, F(t) > G9t) for t > 0 when X and Y are random variables symmetric about 0, with c.d.f.s F and G. Two examples are provided.

  • PDF

The Study on Application of Flying Inspection Method for the 22.9kV Distribution Line (22.9kV 배전선로 비행점검 방법 적용에 관한 연구)

  • Zhang, Jeong-Il;Kang, Byoung-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.194-198
    • /
    • 2012
  • This paper describes flying inspection apparatus for 22.9kV distribution line. This apparatus is composed of multi-copter(more than 4 propellers), camcorder and remote controller. The existing inspections, such as hot-line inspection job and optical inspection method and distribution Line Checking Robot, have many restrictions. A electric working vehicle and hot-line job license are essential in hot-line inspection job. Besides its high cost, it can't be applied to the electric pole over 18m and road-blocked area. Optical method can't inspect upper side of electric facilities mounted on the electric pole. Robot method can't be applied to the corroded overhead earth wire and nothing of overhead earth wire. To solve the problems, in Korea Electric Power Co., we have applied flying inspection apparatus to the 22.9kV distribution line. The results of trial application show that this paper is practical and effective for the inspection technical method in 22.9kV distribution line

Hydrological Studies on the best fitting distribution and probable minimum flow for the extreme values of discharge (極値流量의 最適分布型과 極値確率 流量에 關한 水文學的 硏究 -錦江流域의 渴水量을 中心으로-)

  • Lee, Soon-Hyuk;Han, Chung-Suck
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.4
    • /
    • pp.108-117
    • /
    • 1979
  • In order to obtain the basic data for design of water structures which can be contributed to the planning of water use. Best fitted distribution function and the equations for the probable minimum flow were derived to the annual minimum flow of five subwatersheds along Geum River basin. The result were analyzed and summarized as follows. 1. Type III extremal distribution was considered as a best fit one among some other distributions such as exponential and two parameter lognormal distribution by $x^2$-goodness of fit test. 2. The minimum flow are analyzed by Type III extremal distribution which contains a shape parameter $\lambda$, a location parameter ${\beta}$ and a minimum drought $\gamma$. If a minimum drought $\gamma=0$, equations for the probable minimum flow, $D_T$, were derived as $D_T={\beta}e^{\lambda}1^{y'}$, with two parameters and as $D_T=\gamma+(\^{\beta}-\gamma)e^{{\lambda}y'}$ with three parameters in case of a minimum drought ${\gamma}>0$ respectively. 3. Probable minimum flow following the return periods for each stations were also obtained by above mentioned equations. Frequency curves for each station are drawn in the text. 4. Mathematical equation with three parameters is more suitable one than that of two parameters if much difference exist between the maximum and the minimum value among observed data.

  • PDF

Notes on the Goodness-of-Fit Tests for the Ordinal Response Model

  • Jeong, Kwang-Mo;Lee, Hyun-Yung
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.6
    • /
    • pp.1057-1065
    • /
    • 2010
  • In this paper we discuss some cautionary notes in using the Pearson chi-squared test statistic for the goodness-of-fit of the ordinal response model. If a model includes continuous type explanatory variables, the resulting table from the t of a model is not a regular one in the sense that the cell boundaries are not fixed but randomly determined by some other criteria. The chi-squared statistic from this kind of table does not have a limiting chi-square distribution in general and we need to be very cautious of the use of a chi-squared type goodness-of-t test. We also study the limiting distribution of the chi-squared type statistic for testing the goodness-of-t of cumulative logit models with ordinal responses. The regularity conditions necessary to the limiting distribution will be reformulated in the framework of the cumulative logit model by modifying those of Moore and Spruill (1975). Due to the complex limiting distribution, a parametric bootstrap testing procedure is a good alternative and we explained the suggested method through a practical example of an ordinal response dataset.

Distribution Characteristics of Polycyclic Aromatic Hydrocarbons (PAHs) in Soils in Jeju City of Jeju Island, Korea (제주시 토양 중 다환방향족탄화수소류(PAHs)의 분포 특성)

  • Jin, Yu-Kyoung;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.405-415
    • /
    • 2006
  • Sixteen soil samples around six areas (residental area, traffic area, power plant area, incineration area and factory area) where the stationary and mobile sources of polycyclic aromatic hydrocarbons (PAHs) are estimated to be emitted in Jeju City, were collected during Feburuary to March, 2004, and analyzed for 16 PAHs recommended by US EPA as primary pollutants to investigate their distribution characteristics. The concentrations of total PAHs (t-PAHs) and total carcinogenic PAHs $(t-PAH_{CARC})$ in soils of Jeju City were in the range of $21.7\sim264.2ng/g$ on a dry weight basis with a mean value of 87.2 ng/g and $6.3\sim118.0ng/g$ with a mean value of 33.4 ng/g, respectively. The concentrations of t-PAHs were low in comparison with those in soils of other domestic and foreign countries. The mean concentrations of t-PAHs and $(t-PAH_{CARC})$ with area decreased in the following sequences: traffic area> incineration area > factory area > power generation area > harbor area enli residental area. The correlation between t-PAHs and $(t-PAH_{CARC})$ were very high $(\gamma^2=0.9701)$, indicating that $(t-PAH_{CARC})$ concentration increases in proportion with t-PAHs. Comparing the distribution ratio of ring PAHs with area among 16 PAHs, it decreased in the order of 4-ring > 5-ring > 6-ring > 3-ring > 2-ring in all the areas except for harbor area. whitens for harbor area it was similar among 3-, 4- and 5-ring with high value. Low and no correlations between t-PAHs and soil compositions (organic matter content and particle size distribution) were observed, which is considered to be caused by the complex factors, such as the loading and characteristics of PAHs and diverse soil environment change, etc. From the examination of the three PAH origin indices, such as LMW/HMW (low molecular weight $2\sim3$ ring PAHs over high molecular weight $4\sim6$ ring PAHs), phenanthrene/anthracene ratio and fluoranthene/pyrene ratio, it can be concluded that the soil PAH contaminations were ascribed to strong pyrogenic origin in ail areas except for harbor area and to both pyrogenic and petrogenic origins.

Application of DC distribution IPS to a 10t Class Fishing Boat (10톤급 어선에의 DC 배전 전기 추진 선박 적용)

  • Son, Young-Kwang;Choe, Sehwa;Lee, Seung-Yong;Kim, So-Yeon;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.353-359
    • /
    • 2017
  • To take advantage of electric propulsion, several large vessel kinds, namely, cruise vessels, icebreakers, drill ships, and warships, have been generally designed with Integrated Power System (IPS). Although most of these vessels have adopted AC distribution IPS, DC distribution IPS ships have recently emerged as a new promising technology thanks to the availability of the products related to the DC distribution system, in which the system's major advantages over AC distribution are reduced weight and fuel consumption. This paper presents the comparison results of a 10-t class fishing boat for the AC distribution and DC distribution cases. By replacing AC distribution system with DC distribution, 31-41% reduction in the weight of the electrical equipment weight and 20-25% reduction in the fuel consumption are expected.

Pulsed Field Gel Electrophoresis Profile of Erythromycin-Clindamycin Resistant Streptococcus pyogenes Isolated in Korea (국내분리 Erythromycin-Clindamycin 내성 Streptococcus pyogenes에 대한 Pulsed Field Gel Electrophoresis 양상 분석)

  • Lee, Young-Hee;Hwang, Kyu-Jam;Lee, Kwang-Jun;Park, Kang-Soo;Bae, Song-Mee;Sung, Hwa-Young;Kim, Ki-Sang;Lee, Chong-Sam
    • The Journal of the Korean Society for Microbiology
    • /
    • v.35 no.2
    • /
    • pp.171-180
    • /
    • 2000
  • Ninety two strains of Streptococcus pyogenes were isolated from patients with pharyngitis, scarlet fever, skin infection, and invasive streptococcal infections in Seoul, Korea from January to December, 1998. All isolates were epidemiologically characterized by T protein serotype, and serum opacity factor (OF) detection to phenotypes. To analyze the genetic relationship, fifty two isolates including 32 erythromycin-clindamycin (Em-Cm) resistant strains, 20 antimicrobial susceptible strains were attempted to the pulsed-field gel electrophoresis (PFGE). T protein serotype showed 16 kinds in distribution including T12 and T4. Among the total isolates, 40 strains (43.5%) belonged to the T12 serotype and twenty strains (21.7%) to T4 serotype. On the other hand, when infection aspect of S. pyogenes isolates were analysed by T serotype distribution, T12 type was predominant for pharyngitidis which contributed to 21 strains (53%) and for skin infection isolates which contributed to 11 strains (28%), respectively. In case of T4 type, it was the most predominant pharyngitidis isolates which contributed to 8 strains (40%). In T serotype distribution of Em-Cm resistant strains, 27 strains (84%) of the thirty two showed T12 serotype. In minimum inhibitory concentration (MIC) values of Em-Cm resistance isolates, thirty two isolates showed resistant to erythromycin 27 strains (84%), had high MIC of >$128\;{\mu}g/ml$. And also to clindamycin, twenty two strains (69%) had high MIC of >$128\;{\mu}g/ml$. When OF detection of Em-Cm resistance of S. pyogenes isolates were analyzed by T serotype distribution, T12 serotype isolates revealed that all of the isolates except one strain were OF negative. In PFGE profile analysis to Em-Cm resistance isolates, of the twenty seven, Em-Cm resistance of T12 serotype isolates, 26 strains showed identical PFGE profile and all of these isolates revealed that OF negative. Eighty four percent of Em-Cm resistance S. pyogenes isolates had identical phenotype and PFGE profile. These results strongly suggested that the Em-Cm resistant S. pyogenes isolates from Seoul area showed close genetic correlation and PFGE could be available tool for molecular epidemiology.

  • PDF