• Title/Summary/Keyword: systematic index

Search Result 574, Processing Time 0.034 seconds

Reviewing Research on Korean medical treatment of Psoriasis (건선의 한의학적 치료에 관한 논문 경향 분석 - 국내 논문을 중심으로)

  • Hong, Seok-Hoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.26 no.4
    • /
    • pp.26-42
    • /
    • 2013
  • Background : The purpose of this study is to analyze research trends on the korean medical treatment and develop the way of psoriasis cure. Object & Method : This study is based on analysis of recent paper about korean medical treatment of psoriasis using WKUCL(Wonkwang University Central Library) and NDSL(National Discovery for Science Leader). I searched papers using the keyword "Psoriasis". Inclusion criteria was last 13 years. Result : A total 19 studies were found. They turned out to be effective treatment methods of acupuncture, moxibustion, internal medicines, external applications, and evaluation tool of PASI(psoriasis area and severity index). Conclusion : According to the results, korean medical treatments have good effects on psoriasis. If we accumulate the more clinical reports, it will be helpful to map out a systematic treatment of korean medicine on psoriasis.

A Study on Development of City Gas Safety Diagnosis System Index (도시가스 안전 진단 지표 개발에 관한 연구)

  • 정원익;양광모;전형정;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.1-4
    • /
    • 2004
  • Need safety diagnostic indicator pointer that is objective as estimation basis to be scientific and manages systematically safety existing condition and level for city gas facilities. Safety diagnostic indicator pointer can divide by greatly two. One is management (Software) side that one that differ with mechanical (Hardware) side that handle laying stress on equipment connected with safety manages organization and management connected with safety. Weight appropriates according to specific gravity that relevant element occupies in facilities. To give so big value in particular element in grant of weight pays attention because break balance of whole guideline and should gives. Finally, efficient safety net may see effect before self-regulation inside by minimum target establishment by government and legal, systematic countermeasure establishment for this, strict law application and each business proprietor and though activity and user's active safety activity forms harmony properly.

  • PDF

A Cost Effective Reference Data Sampling Algorithm Using Fractal Analysis

  • Lee, Byoung-Kil;Eo, Yang-Dam;Jeong, Jae-Joon;Kim, Yong-Il
    • ETRI Journal
    • /
    • v.23 no.3
    • /
    • pp.129-137
    • /
    • 2001
  • A random sampling or systematic sampling method is commonly used to assess the accuracy of classification results. In remote sensing, with these sampling methods, much time and tedious work are required to acquire sufficient ground truth data. So, a more effective sampling method that can represent the characteristics of the population is required. In this study, fractal analysis is adopted as an index for reference sampling. The fractal dimensions of the whole study area and the sub-regions are calculated to select sub-regions that have the most similar dimensionality to that of the whole area. Then the whole area's classification accuracy is compared with those of sub-regions, and it is verified that the accuracies of selected sub-regions are similar to that of whole area. A new kind of reference sampling method using the above procedure is proposed. The results show that it is possible to reduce sampling area and sample size, while keeping the same level of accuracy as the existing methods.

  • PDF

Bit-Level Systolic Array for Modular Multiplication (모듈러 곱셈연산을 위한 비트레벨 시스토릭 어레이)

  • 최성욱
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 1995.11a
    • /
    • pp.163-172
    • /
    • 1995
  • In this paper, the bit-level 1-dimensionl systolic array for modular multiplication are designed. First of all, the parallel algorithms and data dependence graphs from Walter's Iwamura's methods based on Montgomery Algorithm for modular multiplication are derived and compared. Since Walter's method has the smaller computational index points in data dependence graph than Iwamura's, it is selected as the base algorithm. By the systematic procedure for systolic array design, four 1-dimensional systolic arrays ale obtained and then are evaluated by various criteria. Modifying the array derived from 〔0,1〕 projection direction by adding a control logic and serializing the communication paths of data A, optimal 1-dimensional systolic array is designed. It has constant I/O channels for modular expandable and is good for fault tolerance due to unidirectional paths. And so, it is suitable for RSA Cryptosystem which deals with the large size and many consecutive message blocks.

  • PDF

A Study on the Evaluation Model for Company Selection of Defense Information System R&D Projects (국방 정보시스템 연구개발사업 업체선정 평가모형 개발에 관한 연구)

  • Kim, Sun-Young;Lee, Young-Jae
    • The Journal of Information Systems
    • /
    • v.19 no.2
    • /
    • pp.73-95
    • /
    • 2010
  • This study shows the scientific and systematic Evaluation Model using factor analysis and AHP methods for the success of defense Information System R&D projects. The evaluation model was divided into 7 evaluation factors such as Developing support, Developing infrastructure, Developing management and test & evaluation, Support factors for strength, Understanding & developing strategy, Developing technology & organization, and Developing performance. And those were composed of totally 24 low level Evaluation index. The Developed Evaluation Model in the paper could be contributed more to objectively and transparently company selection of defense Information System R&D and other defense R&D Projects in the future.

Reassessment of SMES Application Studies and Systematic approach Method under Deregulation (전력계통 제어용 초전도에너지 저장장치(SMES)의 검토사례 분석과 전력시장에서의 적용방안)

  • Lee, Geun-Joon;Yoon, Y.B.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.54-56
    • /
    • 2003
  • With the advancement of superconductor materials, especially in HTC YBCO(Gen II), the feasibility of SMES in power systems become much higher than previous days application[1]. Also, with the de-regulation of electricity market, it is indispensable to have a proper estimation of power quality index and power quality cost calcluation mechanism to stabilize highly industrialized society and to vitalize the investment for electric power system. This paper suggests a comprehensive algorithm[2] to determine the policy of SMES investment with the PQ Indices[3] based on aggregated load CBEMA curve reflecting the voltage characteristics such as volatge sags and interruptions which make electric load in unstable operation.

  • PDF

A Study on the optimal structure of 6 D.O.F F/T Sensor using the condition number (조건수를 이용한 6자유도 F/T센서의 최적구조에 관한 연구)

  • 장완식;김재명
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.16-23
    • /
    • 1996
  • In controlling manipulators interacting with the external environment, an important role is played by the Force/Torque(F/T) sensors. Recently, a number of structures for F/T sensors have been proposed, and some criteria for their evaluation have been introduced. This paper presents a systematic analysis of F/T sensor at the design stage. A model of the F/T sensors, based on Stewart Platform structure, is developed on the basis of static and kinematic equation. The condition number defined by the kinematic velocity and force analysis of F/T sensor is used as a performance Index. Thus, 4 optimal structure factors of 6 D.O. F. F/T sensor are determined by using the condition number.

  • PDF

A Study on the Outage Management Standards for Power System (전력계통설비의 정지관리 체계화 방안에 대한 연구)

  • Heo J. Y.;Kim C. H.;Kim J. C.;Lee G. Y.;Lee S. J.;Lee C. G.;Cho B. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.107-109
    • /
    • 2004
  • It is very important to operate a power system safely. An fault may causes the cascading outages in power system. Use of systematic, precise definitions related to the outages is essential for meaningful exchange of data. Moreover, it is necessary that specific instructions for reporting outages is developed. This paper presents the outage management for a power system. The outage managements of the many utilities are researched, which include the definition, classification, index and report of outage. Finally, the outage management standard is proposed, and the necessity and structure of KERC(Korean Electric Reliability Council) are presented

  • PDF

Uncertainty Analysis for Speed and Power Performance in Sea Trial using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 시운전 선속-동력 성능에 대한 불확실성 해석)

  • Seo, Dae-Won;Kim, Min-Su;Kim, Sang-Yeob
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.3
    • /
    • pp.242-250
    • /
    • 2019
  • The speed and power performance of a ship is not only a guarantee issue between the ship owner and the ship-yard, but also is related with the Energy Efficiency Design Index (EEDI) regulation. Recently, International Organization for Standardization (ISO) published the procedure of the measurement and assessment for ship speed and power at sea trial. The results of speed and power performance measured in actual sea condition must inevitably include various uncertainty factors. In this study, the influence for systematic error of shaft power measurement system was examined using the Monte Carlo simulation. It is found that the expanded uncertainty of speed and power performance is approximately ${\pm}1.2%$ at the 95% confidence level(k=2) and most of the uncertainty factor is attributed to shaft torque measurement system.

Orthodontic treatment with clear aligners for a patient with chronic periodontitis

  • Zhang, Jiehua;Li, Jun;Peng, Youjian
    • The korean journal of orthodontics
    • /
    • v.52 no.6
    • /
    • pp.439-450
    • /
    • 2022
  • This case report describes the treatment of an adult female patient with a history of periodontal disease, Class I malocclusion with extrusion, dental spaces, and pathologic tooth migration. The patient was treated with clear aligners, which effectively controlled the strength and direction of orthodontic forces after 3 months of systematic periodontal treatment. The Peer Assessment Rating (PAR) index was calculated from study models before and after treatment. The pretreatment PAR score was 24, and the posttreatment PAR score was 4. The PAR score for this patient changed by 83%. Satisfactory appearance and good function were achieved for this patient.