This study was carried out to separate ovotransferrin in chicken egg white by gel chromatography and heparin affinity chromatography. In gel filtration which was performed with 50mM Phosphate buffer (pH 7.2, 0.15M salt) at a flow rate of 2.0 ml/min, ovotransferrin and ovalbumin were eluted together in fraction number 11-16. In order to separate pure ovotransferrin, fraction No. 12-14 of them which have high concentration of ovotransferrin were concentrated and rechromatographed. However, the ovotransferrin did not separated clearly. In heparin affinity chromatography, the separation was performed with 50mM ethylaminetetraacetic acid (EDTA, pH7.2) and 50mM Phosphate buffer (pH 7.2, 0.15M salt contained) on ferrous and ferric ion saturated column at as same flow rate as gel filtration system's. Ovotransferrin and albumin were eluted together at 10-15min (fraction No.3) and 15-20min (fraction No.4), respectively. However, purified ovotransferrin was eluted at 156-165min and 165-175min (tube No.32-33) with 50 mM phosphate buffer (pH 7.2, 0.15M salt free), respectively. Heparin affinity chromatography with ferric ion saturated column was resulted in the best separation of ovotransferrin rather than separation by gel chromatography and ferrous ion saturated heparin affinity chromatography.
Light Naphtha is distillated from crude oil unit and separated into the methane, ethylene and propylene by boiling point difference in sequence. This separation is conducted using a series of binary-like columns. This separation method is known that the energy consumed in the reboiler is used to separate the heaviest components and most of this energy is discarded as vapor condensation in the overhead cooler. In this study, the first two columns of the separation process are replaced with the Petlyuk column. A structural design was exercised by the stage computation with ideal tray efficiency in equilibrium condition. Compared with the performance of a conventional system of 3-column model, The design outcome shows that the procedure is simple and efficient because the composition of the liquid component in the column tray was designed to be similar to the equilibrium distillation curve. The performance of the new process indicates that an energy saving of 12.1% is obtained and the cost savings of 44 million won per day based on gross domestic product is reduced under same total number of trays and the initial investment cost is saved.
Journal of the Korea Organic Resources Recycling Association
/
v.27
no.2
/
pp.5-12
/
2019
The study is carried out to survey the proper management and to propose an eco - friendly separation system through efficient screening and resource recovery of excavated materials containing waste from various excavating fields such as reconstruction of landfill sites for reuse, reclamation of unsanitary landfill and residential land development of waste dumping sites. The current status and screening process and analytical characteristics of the excavated materials containing waste were reviewed. Through the analysis of the samples such as separated combustibles, recyclable soils and residues collected from the on-site visits we were able to understand the characteristics of separated materials and excavated materials containing waste such as calorific value, elementary composition, TOC, foreign material content and LOI. It has been found that elimination of the moisture of excavations, removal of attached soil from the surfaces of the excavated combustibles and the quantitative supply method of the input devices are the main operating factors as essential factors for the optimal separation of excavated materials containing waste. For efficient management and recycling of excavated materials containing, it is necessary to set criteria of ash content in separated combustibles and criteria organic matter content in separated soils.
You-Yeon Chun;Ha Hyeon Jo;Moonki Baek;Sun Ju Park;Sofia Brito;Bum-Ho Bin
Journal of the Society of Cosmetic Scientists of Korea
/
v.50
no.2
/
pp.143-151
/
2024
Ozone is a colorless, toxic gas that is produced when nitrogen oxides and hydrocarbons undergo a photochemical oxidation reaction in the sun's rays. Even at low concentrations, it affects the respiratory system, causing coughing and other harmful effects. It was confirmed that ozone was generated from nitrogen plasma among cosmetic raw materials, and it was found that the concentration of ozone decreased after 1 day. On the other hand, ozone was not detected in ozone-free plasma generated with argon gas. Therefore, we aimed to produce ozone-free cosmetics by utilizing ozone-free plasma. For efficient plasma processing, the non-sinking method was utilized to inject the plasma into layer separation mists, toners, and ampoules, and the stability was observed. It was found that the successful injection of plasma in the layer separation mist was higher than the other two formulations, but decreased sharply compared to the toner and ampoule. It was found that the ozone-free plasma used did not affect the stability of the layer separation mist, toner, and ampoule under low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃, 50 ℃) conditions. Therefore, this study suggests the importance of ozone-free plasma for cosmetic potential and stability of each formulation.
"The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.
An analytical method using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection was developed for simultaneously analyzing 10 polycyclic aromatic hydrocarbons (PAHs) and 18 nitro-derivatives of PAHs (NPAHs). The two-dimensional HPLC system consists of an on-line clean-up and reduction for NPAHs in the 1st dimension, and separation of the PAHs and the reduced NPAHs and their FL detection in the 2nd dimension after column-switching. To identify an ideal clean-up column for removing sample matrix that may interfere with detection of the analytes, the characteristics of 8 reversed-phase columns were evaluated. The nitrophenylethyl (NPE)-bonded silica column was selected because of its shorter elution band and larger retention factors of the analytes due to strong dipole-dipole interactions. The amino-substituted PAHs (reduced NPAHs), PAHs and deuterated internal standards were separated on polymeric octadecyl-bonded silica (ODS) columns and by dual-channel detection within 120 min including clean-up and reduction steps. The limits of detection were 0.1-9.2 pg per injection for PAHs and 0.1-140 pg per injection for NPAHs. For validation, the method was applied to analyze crude extracts of fine particulate matter ($PM_{2.5}$) samples and achieved good analytical precision and accuracy. Moreover, the standard reference material (SRM1649b, urban dust) was analyzed by this method and the observed concentrations of PAHs and NPAHs were similar to those in previous reports. Thus, the method developed here-in has the potential to become a standard HPLC-based method, especially for NPAHs.
A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.
Kim, Byoung-Sik;Kim, Min;Heo, Kwang-Beom;Hong, Joo-Hee;Na, Won-Jae;Kim, Jae-Hun
Applied Chemistry for Engineering
/
v.18
no.1
/
pp.10-16
/
2007
In this study, we examined the preparation and hydrolysis property of immobilized urease membrane to decompose harmful urea in the body and remove ammonia which was produced by its decomposition. Urease immobilized membrane was prepared by introducing anion-exchange group DEA into porous hollow-fiber membrane by radiation graft polymerization method, and immobilization of urease. When urease was immobilized at membrane introduced with anion-exchange group, the more increasing grafting rate, the more increasing immobilization amount. The result originates from the fact that a greater amount of protein was immobilized by forming a multilayer on the longer grafted chain. Meanwhile, the addition of the cross-linker was possible not only to suppress separation phenomenon produced during a washing process of immobilized urease membrane but also to enable the recycling of membrane. Urease Immobilized membrane with no separation phenomenon was prepared by cross-linking reaction for 5 h, and the hydrolysis rate of prepared urease immobilized membrane was over 98% and 50%, respectively, in 1 mol and 4 mol urea solutions.
Journal of the Korea Institute of Information Security & Cryptology
/
v.29
no.4
/
pp.859-866
/
2019
Cybersecurity attack targeting a specific user is rising in number, even enterprises are trying to strengthen their cybersecurity. Network segmentation environment where public network and private network are separated could block information coming from the outside, however, it is unable to control outside information for business efficiency and productivity. Even if enterprises try to enhance security policies and introduce the network segmentation system and a solution incorporating CDR technology to remove unnecessary data contained in files, it is still exposed to security threats. Therefore, we suggest a system that uses file format conversion to transmit a secure file in the network separation environment. The secure file is converted into an image file from a document, as it reflects attack patterns of inserting malicious code into the document file. Additionally, this paper proposes a system in the environment which functions that a document file can keep information for incident response, considering forensic readiness.
Journal of the Korea Academia-Industrial cooperation Society
/
v.16
no.1
/
pp.735-743
/
2015
The service oriented architecture assures flexibility of enterprise application development, so it supports agile reaction to business change. On the other hand, considerable effort is needed to develop a service by combining business and constraint consumes because the entire combination logic should be changed according to the change in business rule. To improve the current method, this paper applied an aspect oriented approach to service system development. In this paper, the rule concern is proposed in addition to the core concern and cross cutting concern of aspect oriented approach. The rule concern is extracted from business rules included in the business processes and services. The rule concern is classified into the process rule aspect and service rule aspect according to the level of the rule. In the proposed approach, system is modularized into the core concern, cross cutting concern and rule concern through separation of concern, and they are maintained independently. Therefore, the adaptability, reusability, and maintainability of a service system will be enhanced.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.