• Title/Summary/Keyword: system separation method

Search Result 742, Processing Time 0.031 seconds

Wave Power Extraction by Strip Array of Multiple Buoys (스트립 배열된 다수 부이에 의한 파력에너지 추출)

  • Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.474-483
    • /
    • 2014
  • The majority of existing WECs (wave energy converters) are designed to achieve maximum power at a resonance condition. In the case of a single WEC, its size must be large enough for tuning, and it has high efficiency only within a limited frequency band. Recently, wave power extraction by deploying many small buoys in a compact array has been studied under the assumption that the buoy's size and separation distance are much smaller than the water depth, wave length, and size of the array. A boundary value problem involving the macro-scale boundary condition on the mean surface covered by an infinite strip of buoys is solved using the eigenfunction expansion method. The energy extraction efficiency (${\varepsilon}=1-R^2_f-T^2_r$), where $R_f$ and $T_r$ are the reflection and transmission coefficients for a strip array of buoys, is assessed for various combinations of packing ratio, strip width, and PTO damping coefficient.

Noise and flow analysis of lift-type disk wind power System (양력형 디스크 풍력 발전기의 유동 및 소음 해석)

  • Ko, Seungchul;Na, Jisung;Lee, Joon Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.3
    • /
    • pp.52-56
    • /
    • 2017
  • In this study, we investigate the flow characteristics of lift-type disk which behaves the up-down motion using the large eddy simulation (LES) and immersed boundary method (IBM). Also, we perform the noise analysis using pressure field at 1.35 m distance and reveal the cause of noise to observe the vortical structure analysis of flow result. It is observed that vortical structure and wind shear were generated at leading edge and tower with high velocity deficit and flow separation. High magnitude of flow noise was observed in low frequency range which is from 30 Hz to 60 Hz. It was observed that vortical structure at leading edge was generated in frequency range from 33.3 Hz to 41.6 Hz. Temporal characteristic in vortical structure at leading edge was similar to noise characteristics, having the similar frequency ranges.

Dominant components of vibrational energy flow in stiffened panels analysed by the structural intensity technique

  • Cho, Dae-Seung;Choi, Tae-Muk;Kim, Jin-Hyeong;Vladimir, Nikola
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.583-595
    • /
    • 2018
  • Stiffened panels are widely used in naval architecture and ocean engineering, and knowledge about their dynamic behaviour represents important issue in the design procedure. Ordinary vibration analysis consists of natural frequencies and mode shapes determination and can be extended to forced response assessment, while the Structural Intensity (SI) analysis, assessing magnitude and direction of vibrational energy flow provides information on dominant transmission paths and energy distribution including sink positions. In this paper, vibrational energy flow in stiffened panels under harmonic loading is analyzed by the SI technique employing the finite element method. Structural intensity formulation for plate and beam element is outlined, and developed system combining in-house code and general finite element tool is described. As confirmed within numerical examples, the developed tool enables separation of SI components, enabling generation of novel SI patterns and providing deeper insight in the vibrational energy flow in stiffened panels, comparing to existing works.

The Separation of NTSC Signal Components by Using Adaptive Selection Method of Horizontal and Vertical Filters (수평 및 수직 필터의 적응적 선택에 의한 NTSC 칼라영상신호의 성분분리)

  • 권병헌;황병원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.2
    • /
    • pp.211-224
    • /
    • 1994
  • In this paper, a multi-level adaptive intraframe method has been proposed to separate the luminance and chominance components in NTSC composite signal. The control signals are generated by detecting the vertical correlation and transition in the horizontal and diagonal directions. The chrominance component is adaptively processed through vertical and horizontal filters according to the control signals and the luminance component is processed by subtracting the chrominance component from the composite video signal. The several filters have been used at the sampling rate of four times the color subcarrier frequency and computer simulation and SVP(Serial Video Processing) system have been introduced to compare the performance of the conventional methods and that of proposed one.

  • PDF

Heat Transfer Measurements by a Round Impinging Jet on a Rib-Roughened Flat Plate (표면조도를 가진 평판에서 원형충돌제트에 의한 열전달 측정)

  • Lee, Dae-Hee;Kim, Yun-Taek;Chung, Seung-Hun;Chung, Young-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.87-92
    • /
    • 2000
  • This study is to investigate the heat transfer characteristics the for a round turbulent jet impinging on the flat plate with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured using liquid crystal and a digital color image processing system. The experiments were made fur the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, and the rib type [height ($d_1$) 2mm, pitch (p) from 12 to 36mm]. It was found that for $L/d{\ge}6$ the average Nusselt numbers on the flat plate with rib type C ($p/d_1=16$) are higher than those without rib, mainly due to an increase in the turbulent intensity caused by flow separation, recirculation and reattachment on the wall surface.

  • PDF

Contribution Analysis of Simulated Pass-by Data using Operational Transfer Path Analysis

  • Lohrmann, Martin;Kluiber, Florian
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.123-125
    • /
    • 2010
  • As the exterior noise emitted by a vehicle is getting more and more attention, simulated pass-by measurements become more important. This well established method provides information about the total noise emitted by the vehicle. For a vehicle manufacturer it is not only interesting to know about the total noise but also to know how this total exterior noise is composed of different contributions, such as for example the contribution of the engine, the intake or exhaust system. Transfer path analysis (TPA) provides a separation of these contributions for each of the pass-by microphones alongside the track. Presented is a method for fast and efficient determination of the contributions of multiple sources using operational transfer path analysis (OTPA). The calculation of the transfer characteristics between the reference measurement points on the vehicle and the corresponding response points of both microphone lines are carried out while operation of the vehicle. As result of the contribution analysis from operational transfer path analysis, the characteristic noise level as function of the covered distance is displayed for all individual sound sources, thus providing in depth information for sound quality engineering.

  • PDF

Isolatin and Quantitative Determination of 20-Hydroxyecdysone from Achyranthis Radix (우슬로부터 20-Hydroxyecdysone의 분리 및 함량분석)

  • Hwang, Ji-Hyun;Lee, Seung-Ho;Park, Jeong-Hill;Kang, Shin-Jung;Chang, Seung-Yeup;Lee, Kyong-Soon;Son, Kun-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.30 no.3
    • /
    • pp.335-339
    • /
    • 1999
  • Separation and quantitative determination of 20-hydroxyecdysone from Achyranthis Radix has been conducted by using HPLC method. 20-hydroxyecdysone in a methanol extract from the raw drug was separated on a reverse phase column using a $CH_3CN-H_2O\;(18:82)$ solvent system and the average content is $0.0931{\pm}0.0048%$. For the preparation of authentic standard, we isolated 20-hydroxyecdysone from the roots of Achyranthes fauriei by $SiO_2$ and RP-18 column chromatography.

  • PDF

Quantitative Analysis of Bioactive Compounds in the Fruits of Crataegus pinnatifida by High-Performance Liquid Chromatography

  • Bae, Yoon-Ho;Cuong, To Dao;Lee, Jae-Hyun;Woo, Mi-Hee;Choi, Jae-Sue;Min, Byung-Sun
    • Natural Product Sciences
    • /
    • v.18 no.2
    • /
    • pp.83-88
    • /
    • 2012
  • In order to facilitate the quality control of the fruits of Crataegus pinnatifida, a simple, accurate and reliable HPLC method was developed for the simultaneous determination of the three bioactive compounds: chlorogenic acid (1), rutin (2), and hyperin (3), which were selected as the chemical markers of C. pinnatifida. Separation was achieved on an Agilent Eclipse XDB-C18 column with a gradient solvent system of 0.1% trifluoroacetic acid aqueous-acetonitrile at a flow-rate of 1.0 mL/min and detected at 254nm. All three calibration curves showed good linearity ($R^2$ > 0.998). The recoveries of three marker compounds were in the range of 94.87~111.52 %. The contents of chlorogenic acid (1), rutin (2), and hyperin (3) of the fruits of C. pinnatifida collected from 23 district markets in Korea, Japan, and China were 0.16~0.65 mg/g, 0.07~1.24 mg/g, and 0.03~0.62 mg/g, respectively. The results demonstrated that this method is simple and reliable for the quality control of the fruits of C. pinnatifida.

Quantitative Analysis of the Ten Phytochmicals in Acer tegmentosum Maxim by UPLC-MS/MS (UPLC-MS/MS를 이용한 산천목 중 10종 성분의 함량 분석)

  • Hwang, Youn-Hwan;Li, Wei;Yang, Hye Jin;Ma, Jin Yeul
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • Acer tegmentosum Maxim (ATM) has been used to treat hepatic disorders in traditional oriental medicine. However, there is little information about phytochemical constituents for quality control of ATM. In this study, we developed and established a simultaneous analytical method of the 10 marker compounds (three coumarins, 3 flavonoids, 1 lignan, 3 phenolics) in ATM using ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS). Chromatographic separation of ten target analytes was achieved with a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$), using a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile with gradient elution. Identifications and quantitation of all analytes were performed using a Q-Exactive UPLC-MS/MS system. Correlation coefficients of the calibration curve for all analytes were ${\geq}0.9986$. The values of limits of detection and quantification of all analytes were 0.5-10.0 and 5.0-50.0 ng/mL, respectively. The established UPLC-MS/MS method successfully identified all target analytes in ATM, and the phytochemicals were 0.01-67.98 mg/g in its lyophilized water extract.

Study on the spectroscopic reconstruction of explosive-contaminated overlapping fingerprints using the laser-induced plasma emissions

  • Yang, Jun-Ho;Yoh, Jai-Ick
    • Analytical Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.86-97
    • /
    • 2020
  • Reconstruction and separation of explosive-contaminated overlapping fingerprints constitutes an analytical challenge of high significance in forensic sciences. Laser-induced breakdown spectroscopy (LIBS) allows real-time chemical mapping by detecting the light emissions from laser-induced plasma and can offer powerful means of fingerprint classification based on the chemical components of the sample. During recent years LIBS has been studied one of the spectroscopic techniques with larger capability for forensic sciences. However, despite of the great sensitivity, LIBS suffers from a limited detection due to difficulties in reconstruction of overlapping fingerprints. Here, the authors propose a simple, yet effective, method of using chemical mapping to separate and reconstruct the explosive-contaminated, overlapping fingerprints. A Q-switched Nd:YAG laser system (1064 nm), which allows the laser beam diameter and the area of the ablated crater to be controlled, was used to analyze the chemical compositions of eight samples of explosive-contaminated fingerprints (featuring two sample explosive and four individuals) via the LIBS. Then, the chemical validations were further performed by applying the Raman spectroscopy. The results were subjected to principal component and partial least-squares multivariate analyses, and showed the classification of contaminated fingerprints at higher than 91% accuracy. Robustness and sensitivity tests indicate that the novel method used here is effective for separating and reconstructing the overlapping fingerprints with explosive trace.