• Title/Summary/Keyword: system separation method

Search Result 742, Processing Time 0.03 seconds

Evaluation of Separation on the Copper Recovery from Jelly filled type Cable (젤리충전통신케이블의 구리회수를 위한 친환경적 분리기술평가)

  • Min, Dal-Ki;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.21-26
    • /
    • 2003
  • The generation of waste cable has been continuously increased as a production of electrical and communication media are extended. The current recovery methods, such as mechanical peeling, incineration, solvent extraction and pyrolysis, seems inadequate because they are either hard to apply in some cases or environmentally unacceptable. It has been shown that copper can be effectively separated from the jelly filled type cables using a soybean oil treatment method. As a result, jelly compound is vanished from the wire by soybean oil bath and waste wires are separated copper and PE by the mechanical chipper. This is a more environmentally friendly method than burning, and considerably faster than Stripping.

A New HPLC Condition for the Analysis of Aclacinomycins A and Y in the Mixtures of Aclacinomycins

  • Kim, Wan Seop;Won Tae Cho;Myung Kook Kim;Sang Ki Rhee;Hak Ryul Kim;Eul Sung Choi
    • Journal of Microbiology and Biotechnology
    • /
    • v.5 no.5
    • /
    • pp.302-304
    • /
    • 1995
  • As the previous HPLC method (Ogasawara et al., 1983) was described for the analysis of aclacinomycin A and some of its analogue compounds but not for aclacinomycin Y, we developed novel HPLC condition by optimizing solvent system. The newly developed solvent system allowed a complete separation of aclacinomycins Y and A, as opposed to the incomplete resolution of these two compounds in conventional method. The amounts of aclacinomycins Y and A could be accurately determined when the fermentation broth of Streptomyces lavendofoliae DKRS was analyzed by the newly developed method.

  • PDF

Mixing matrix estimation method for dual-channel time-frequency overlapped signals based on interval probability

  • Liu, Zhipeng;Li, Lichun;Zheng, Ziru
    • ETRI Journal
    • /
    • v.41 no.5
    • /
    • pp.658-669
    • /
    • 2019
  • For dual-channel time-frequency (TF) overlapped signals with low sparsity in underdetermined blind source separation (UBSS), this paper proposes an effective method based on interval probability to estimate and expand the types of mixing matrices. First, the detection of TF single-source points (TF-SSP) is used to improve the TF sparsity of each source. For more distinguishability, as the ratios of the coefficients from different columns of the mixing matrix are close, a local peak-detection mechanism based on interval probability (LPIP) is proposed. LPIP utilizes uniform subintervals to optimize and classify the TF coefficient ratios of the detected TF-SSP effectively in the case of a high level of TF overlap among sources and reduces the TF interference points and redundant signal features greatly to enhance the estimation accuracy. The simulation results show that under both noiseless and noisy cases, the proposed method performs better than the selected mainstream traditional methods, has good robustness, and has low algorithm complexity.

Microdevice for Separation of Circulating Tumor Cells Using Embedded Magnetophoresis with V-shaped Ni-Co Nanowires and Immuno-nanomagnetic Beads

  • Park, Jeong Won;Lee, Nae-Rym;Cho, Sung Mok;Jung, Moon Youn;Ihm, Chunhwa;Lee, Dae-Sik
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.233-240
    • /
    • 2015
  • The novelty of this study resides in a 6"-wafer-level microfabrication protocol for a microdevice with a fluidic control system for the separation of circulating tumor cells (CTCs) from human whole blood cells. The microdevice utilizes a lateral magnetophoresis method based on immunomagnetic nanobeads with anti-epithelial cell adhesive molecule antibodies that selectively bind to epithelial cancer cells. The device consists of a top polydimethylsiloxane substrate for microfluidic control and a bottom substrate for lateral magnetophoretic force generation with embedded v-shaped soft magnetic microwires. The microdevice can isolate about 93% of the spiked cancer cells (MCF-7, a breast cancer cell line) at a flow rate of 40/100 mL/min with respect to a whole human blood/buffer solution. For all isolation, it takes only 10 min to process 400 mL of whole human blood. The fabrication method is sufficiently simple and easy, allowing the microdevice to be a mass-producible clinical tool for cancer diagnosis, prognosis, and personalized medicine.

Numerical analysis of the differential pressure venturi-cone flowmeter (차압식 벤튜리콘 유량계에 대한 유동해석)

  • 윤준용;맹주성;이정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.714-720
    • /
    • 1998
  • The differential pressure venturi-cone flowmeter is an advanced flowmeter which has many advantages such as wide range of measurement, high accuracy, excellent flow turn-down ratio, low headless, short installation pipe length requirement, and etc. Like other differential pressure flowmeters, the venturi-cone flowmeter uses the law of energy conservation, but its shape and position make it perform better than others. The cone acts as its own flow conditioner and mixer, fully conditioning and mixing the flow prior to measurement. For the analysis, we used Reynolds-averaged Wavier-Stokes equations and k-$\omega$ turbulence model. The equations were fully transformed into the computational domain, the pressure-velocity coupling was made through SIMPLER algorithm, and the equations were discretized using finite analytic solutions of the liberalized equations(Finite Analytic Method). To control the separation phenomenon on the cone surface, we proposed a new shape of cone, and analyzed the flowfield in the new flowmeter system, and found the improvement on the performance of the new cone flowmeter.

  • PDF

Capillary Size-exclusion Chromatography as a Gel-free Strategy in Plasma Proteomics

  • Cho, Man-Ho;Wishnok, John S.;Tannenbaum, Steven R.
    • Molecular & Cellular Toxicology
    • /
    • v.1 no.2
    • /
    • pp.87-91
    • /
    • 2005
  • Although 2D-PAGE has been widely used as the primary method for protein separation, difficulties in displaying proteins with an extreme values of isoelectric paint (pI), molecular size and hydrophobicity limit the technique. In addition, time consuming steps involving protein transfer and extraction from the gel-pieces can result in sample loss. Here, we describe a novel protein separation technique with capillary size-exclusion chromatography (CSEC) for rapid protein identification from human plasma. The method includes protein fractionation along with molecular size followed by in-solution tryptic digestion and peptide analysis through reversed phase liquid chromatography (RPLC) coupled to nanoflow electrospray-tandem mass spectrometry (ESI-MS/MS). Tryptic peptides are applied an a $100\;{\mu}m\;i.d.{\times}10mm$ length pre-column and then separated on a $75\;{\mu}m{\times}200mm$ analytical column at -100 nL/min flaw rate. Proteins were identified over the wide ranges of pI (3.7-12.3) when this technique was applied to the analysis of $1-2\;{\mu}L$ of human plasma. This gel-free system provides fast fractionation and may be considered a complementary technique to SDS-PAGE in proteomics.

BINARY MICROLENSING EFFECTS I. CAUSTICS AND THE FLUX FACTOR K

  • LEE DONG WOOK;CHANG KYONG AE;KIM SANG JOON
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.1
    • /
    • pp.27-37
    • /
    • 1998
  • We have made semi-analytical studies to investigate the configurations of caustics and the probability distribution of the flux factor K for the binary microlensing including external shears. A parametric equation of critical curve is derived in a 4th order complex polynomial. We present the topological dependencies of the caustics for selected gamma parameters (0, 0.3, 0.6, 1.3, 2.0, and 2.5) and convergence terms (0., 0.4, 0.8, 1.2, 1.6, and 2.0). For the purpose of analyzing the efficiency of High Amplification Event (HAE) on each caustics, we examine the probability distribution of the flux factor by a Monte Carlo method. Changing the separation of the binary system from 0.8 to 1.3 (in normalied unit), we examine the probability distribution of the K-values in various gamma parameters. The relationship between gamma parameters, seperations and their probabilties of the flux factor K have been studied. Our results show that the relatively higher K values (K>1.5) are increased as increasing the separation of the binary system. We therfore conclude that, in the N-body microlensing, the probabilities of higher HAEs are inversely proportional to the star density as well. We also point out that the present research might be used as a preliminary step toward investigating heavy N-body microlensing simulations.

  • PDF

Preparation and Controlled Release of Microcapsules Containing $Ketoprofen-{\beta}-Cyclodextrin$ Solid Dispersion (케토프로펜-${\beta}$-시클로덱스트린 고체분산체의 마이크로캅셀화 및 제어 방출)

  • Chun, In-Koo;Park, Jung-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.33-40
    • /
    • 1992
  • This study was aimed to control the release characteristics of ketoprofen by microencapsulating $ketoprofen-{\beta}-cyclodextrin\;(KF-{\beta}-CyD)$ solid dispersion with Eudragit RS by the phase separation method using a nonaqueous vehicle. KF alone was also microencapsulated with Eudragit RS by the evaporation process in water phase. The results obtained showed that it was not possible to microencapsulate KF alone by phase separation in a chloroform-cyclohexane system while it was easy to microencapsulate $(KF-{\beta}-CyD)$ solid dispersion system. For the microcapsules, the release test was performed in the first fluid (pH 1.2) and the second fluid (pH 6.8) of K.P.V disintegration medium at $37^{\circ}C$. The release of KF from $(KF-{\beta}-CyD)$ solid dispersion microcapsules (1:1 core wall ratio) was more sustained than that from KF microcapsules, and followed zero-order kinetics. Especially, solid dispersion microcapsules showed pH-independent release patterns with higher wall to core ratio (1:1 w/w).

  • PDF

A Study on Flow and Creation and Dissipation of Vorticity around Rectangular Floating Breakwater (부방파제의 유동과 와의 생성 및 소멸에 관한 연구)

  • Yoon, Jung-Sung;Kim, Myoung-Kyu;Jung, Kwang-Hyo;Kim, Ga-Ya
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.24-33
    • /
    • 2008
  • In this study, flow and creation and dissipation of vorticity around rectangular floating breakwater is investigated both experimentally and numerically. The PIV system(Particle image velocimetry) is employed to obtain the velocity field in the vorticity of rectangular structure. The numerical model, combined with ${\kappa}-{\varepsilon}$ turbulence model and the VOF method based on RANS equation, is used to analyze the turbulence structure. In the results of this study, the vorticity is found around conner of rectangular structure at all time domain, and creation and dissipation of vorticity are closely related to wave period. Separation points of phase of vortex due to flow separation for longer period waves are faster then for shorter period waves.

Evaluation of Application of High Quality Recycled Fine Aggregate Manufacturing System by the Drying Specific Gravity Separation Method (건식비중분리법에 의한 고품질 재생잔골재 제조생산 시스템의 적용성 평가)

  • Kim Moo-Han;Kim Jae-Hwan;Kim Yong-Ro;Na Chul-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.69-76
    • /
    • 2005
  • In this study, the high qualify recycled fine aggregate manufacturing system by the drying specific gravity separation method was evaluated. For the evaluation of the performance of the recycled aggregate, the engineering properties and durability of recycled aggregate has been tested. From the test results, the quality of recycled fing aggregates was improved by high quality recycled fine aggregate manufacturing system and satisfied with the quality standards of KS and JASS 5. Also, compressive and tensile strengths of recycled concrete show no critical difference caused by recycled fine aggregate replacement ratio. However, durability such as carbonation depth chloride ion penetration depth and drying shrinkage shows more deterioration than the concrete without recycled fine aggregate