• 제목/요약/키워드: system resistance

검색결과 4,868건 처리시간 0.033초

열차자동운전에 있어서 미지의 주행저항을 고려한 강인한 속도제어 (The Robust Speed Control on Automatic Train Operation Considering Unknown Running Resistance)

  • 변윤섭;왕종배;박현준
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권3호
    • /
    • pp.114-119
    • /
    • 2001
  • An automatic train operation(ATO) system executes the operation of constant speed travelling and fixed point parking by using microprocessors instead of driver's manual operation. This paper describes the mathematical model for the train considering unknown disturbances which consist of start resistance, travelling resistance, slope resistance, curve resistance, and so on. The speed controller of ATO system is designed by considering the disturbances. The simulation is executed to verify the speed control and fixed point parking performance and to compare its performance with that of a PID-type ATO control system under disturbances. Simulation results show that the control performance of gain scheduled control scheme for ATO system is better than that of the conventional PID controller.

  • PDF

미지의 주행저항을 고려한 도시철도차량 ATO의 속도추종 및 정밀정차 제어 (The speed regulation and fixed point parking control of urban railway ATO considering unknown running resistance)

  • 변윤섭;한성호;김길동;백광선;한영재
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.280-287
    • /
    • 1999
  • An automatic train operation(ATO) system executes the operation of constant speed travelling and fixed point parking by using microprocessors instead of drivers manual operation. This paper describes the mathematical model for the train considering unknown disturbances which consist of start resistance, travelling resistance, slope resistance, curve resistance, and so on. The speed controller of ATO system is designed by considering the disturbances. The simulation is executed to verify the speed control and fixed point parking performance and to compare its performance with that of a PID-type ATO control system under disturbances. Simulation results show that the control performance of gain scheduled control scheme fur ATO system is better than that of the conventional PID controller.

  • PDF

Ofloxacin Resistance Mechanism in PA150 and PA300-Clinical Isolates of Pseudomonas aeruginosa in Korea

  • Lee, Soon-Deuk;Lee, Yeon-Hee
    • Archives of Pharmacal Research
    • /
    • 제21권6호
    • /
    • pp.671-676
    • /
    • 1998
  • Five hundred and seventy clinical strains of Pseudomonas aeruginosa were isolated from August 1993 to August 1994 in Korea and screened for their resistance to ciprofloxacin, norfloxacin, and ofloxacin. Among these, two P. aeruginosa strains (PA150 and PA300) were selected based on their strong resistance (MICs > 50mcg/ml) to all three quinolones. The susceptible strain as well as two resistant strains had proton gradient-dependent efflux system. Efflux system in PA300 showed different specificities to ofloxacin and ciprofloxacin while PA150 had less permeability for ofloxacin. Ofloxacin had a less inhibitory action on DNA synthesis in permeabilized cells of PA150 and PA300 than 1771M. When quinolone resistance determining region (QRDR) in gyrA was sequenced, PA300 had one missense mutation, Asn 116Tyr, which was newly reported in this work. The results showed that PA150 became ofloxacin resistant by reduced ofloxacin accumulation due to the existence of efflux system and low permeability, while resistance of PA300 was due to the efflux system and a mutation in QRDR of gyrA -the target site of quinolone.

  • PDF

국소마취에 의한 발한 억제 상태에서 침자극이 인체 전기 저항에 미치는 영향 (Influence of Acupuncture Stimulation on Electrical Resistance under Adiaphoresis Induced by Regional Anaesthesia)

  • 박경모
    • Journal of Acupuncture Research
    • /
    • 제17권4호
    • /
    • pp.130-138
    • /
    • 2000
  • Objectives : When sweating factor is excluded, to know the influence of acupuncture stimulation on electrical resistance. Methods : Regional anaesthesia(Lidocane 2%, 1ml, Subcutaneous injection) is applied to measured regions, 4cm round area including left Neiguan P6. So we can make adiaphoresis. Before and after acupucnture stimulation to Laogong P8, we measured the electrical resistance of anesthetized left Neiguan P6, anesthetized non-acupoint, normal left Ximen P4, and normal right Neiguan P6. For measurment, we use the 1.2V, DC system that has 100$k{\Omega}$ internal resistance Results : Under the adiaphoresis, Acupuncture stimulation makes the significant decrease of electrical resistance. In normal regions, so does it. Conclusions : When the acupuncture stimulation is applied to human boby, the decrease of electrical resistance is due not only to sweat secretion but also to other internal resistance.

  • PDF

Presticide Resistance Menagement of Pest and Beneficial Arthropods and More Biologically-Based IPM on Apple

  • Croft, B.A.
    • 한국응용곤충학회지
    • /
    • 제32권4호
    • /
    • pp.373-381
    • /
    • 1993
  • Resistance evolution to organophosphate-based pesticides in apple and pear inhabiting arthropods of western North America extends to many classes of pest and some beneficial species. Resistance management programs to minimize resistance in pests while exploiting it in natural enemies have met with mixed success. Among beneficials, resistances have been exploited mostly among predators of pest mites. Evolution of resistant mites, leafminers, leafhopper, aphids, leafrollers and some internal fruit feeders have led to development of new monitoring methods and means to delay or avoid resistance. But it is resistance to azinphosmethyl in codling moth (Cydia pomonella) that is changing the pest control system and moving it from chemical to biologically-based means. Newly merging IPM system will depend more on use of biological, cultural, behavior and genetic controls. But more selective pesticides also will be needed to augment pheromones, resistant host plants and genetically altered organisms. These more biologically-based tactics will be prone to resistance evolution in pests as well, if used too unilaterally and/or too extensively.

  • PDF

낮은 저항과 열안정성을 가지는 Cu/Mn 합금저항의 전기적 특성 (Electrical Properties of Cu/Mn Alloy Resistor with Low Resistance and Thermal Stability)

  • 김은민;김성철;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제29권6호
    • /
    • pp.365-369
    • /
    • 2016
  • In this paper, we fabricated Cu/Mn alloy shunt resistor with low resistance and thermal stability for use of mobile electronic devices. We designed metal alloy composed of copper (Cu) and manganese (Mn) to embody in low resistance and low TCR which are conflict each other. Cu allows high electrical conductivity and Mn serves thermal stability in this Cu/Mn alloy system. We confirmed the elemental composition of the designed metal alloy system by using energy dispersive X-ray (EDX) analysis. We obtained low resistance below $10m{\Omega}$ and low temperature coefficient of resistance (TCR) below $100ppm/^{\circ}C$ from the designed Cu/Mn alloy resistor. And in order to minimize resistance change caused by alternative frequency on circuit, shape design of the metal alloy wire is performed by rolling process. Finally, we conclude that design of the metal alloy system was successfully done by alloying Cu and 3 wt% of Mn, and the Cu/Mn alloy resistor has low resistance and thermal stability.

TCP/IP 기반의 원격 저항 점 용접 품질 모니터링 시스템에 관한 연구 (A Study of Remote Welding Quanlity Monitoring System using TCP/IP in Resistance Spot Welding)

  • 최윤석;이세헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2001
  • Nowadays, computer network has been rapidly developed. And we have made efforts to use it in wide field. So we can exchange data without spacial restriction using internet. If we develop monitoring system using internet, we have the effect of reducing time and space. Therefore, in this paper, we developed TCP/IP network and client/server system. And We applied them to resistance spot welding quality monitoring system.

  • PDF

환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performace of Intumescent Coating System by Environmental Testing Procedure)

  • 박수영;성시창;최동호;김대회;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.

  • PDF

Evaluation of AC Resistance in Litz Wire Planar Spiral Coils for Wireless Power Transfer

  • Wang, Xiaona;Sun, Pan;Deng, Qijun;Wang, Wengbin
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1268-1277
    • /
    • 2018
  • A relatively high operating frequency is required for efficient wireless power transfer (WPT). However, the alternating current (AC) resistance of coils increases sharply with operating frequency, which possibly degrades overall efficiency. Hence, the evaluation of coil AC resistance is critical in selecting operating frequency to achieve good efficiency. For a Litz wire coil, AC resistance is attributed to the magnetic field, which leads to the skin effect, the proximity effect, and the corresponding conductive resistance and inductive resistance in the coil. A numerical calculation method based on the Biot-Savart law is proposed to calculate magnetic field strength over strands in Litz wire planar spiral coils to evaluate their AC resistance. An optimized frequency can be found to achieve the maximum efficiency of a WPT system based on the predicted resistance. Sample coils are manufactured to verify the resistance analysis method. A prototype WPT system is set up to conduct the experiments. The experiments show that the proposed method can accurately predict the AC resistance of Litz wire planar spiral coils and the optimized operating frequency for maximum efficiency.

쐐기형 그라운드앵커의 인발 거동 특성 (Pullout Resistance Characteristics of the Wedge-shaped Ground Anchor)

  • 김정무;정원용;윤용수;정민규;장순호;이용준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1060-1064
    • /
    • 2010
  • Ground anchors are mostly used to improve the resistance capacity of retaining walls. The end of the anchor is connected to retaining wall through tendons and the forces in tendons are transferred to ground. In this study, we plan that the new anchor system increases the tension force in tendons and improves the pullout resistance characteristics of the system. In order to increase the pullout resistance capacity of existing anchor system, the new anchor system is made by attaching four steel sticks to the tip of anchor end. So the field test results showed that the pullout resistance capacity of the wedge-shaped ground anchor was acceptable to elastic displacement range.

  • PDF