• 제목/요약/키워드: system on panel

검색결과 1,563건 처리시간 0.03초

냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

자동차 외판 특징선 곡면의 단면 형상 측정과 분석 (Measurement and Analysis of the Section Profile for Feature Line Surface on an Automotive Outer Panel)

  • 최원창;정연찬
    • 소성∙가공
    • /
    • 제24권2호
    • /
    • pp.107-114
    • /
    • 2015
  • The current study presents a geometric measurement and analysis of the section profile for a feature line surface on an automotive outer panel. A feature line surface is the geometry which is a visually noticeable creased line on a smooth panel. In the current study the section profile of a feature line surface is analyzed geometrically. The section profile on the real press panel was measured using a coordinate measuring machine. The section profiles from the CAD model and the real panel are aligned using the same coordinate system defined by two holes near the feature line. In the aligned section profiles the chord length and height of the curved part were measured and analyzed. The results show that the feature line surface on the real panel is doubled in width size.

Panel heating을 적용한 철골조 건물의 합성테크 진동조건 설정에 관한 연구 (A study on the establishment of vibration conditions of a composite deck floor with panel heating systems for a steel structure)

  • 박진영;김희철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.972-977
    • /
    • 2000
  • One of the major differences of Korean residential building compared with other countries is a rigid diaphragm of a floor due to the panel heating system. An increment of a gravity floor load might cause vibration problem when the composite floor system is introduced to the panel heating system. Since the noise criteria of a residential building is lower than that of an office building, the development of a noise absorbing system should be preceded. The response evaluation was performed for the finished floor, that is with panel heating and noise absorbing system. The natural frequency was obtained both from an experimental study and an analytical study. An appropriate vibration condition of a floor with panel heating and noise absorbing systems was evaluated from this study.

  • PDF

Static and dynamic analytical and experimental analysis of 3D reinforced concrete panels

  • Numayr, K.;Haddad, R.
    • Structural Engineering and Mechanics
    • /
    • 제32권3호
    • /
    • pp.399-406
    • /
    • 2009
  • A three-dimensional panel system, which was offered as a new method for construction in Jordan using relatively high strength modular panels for walls and ceilings, is investigated in this paper. The panel consists of two steel meshes on both sides of an expanded polystyrene core and connected together with a truss wire to provide a 3D system. The top face of the ceiling panel was pored with regular concrete mix, while the bottom face and both faces of the wall panels were cast by shotcreting (dry process). To investigate the structural performance of this system, an extensive experimental testing program for ceiling and wall panels subjected to static and dynamic loadings was conducted. The load-deflection curves were obtained for beam and shear wall elements and wall elements under transverse and axial loads, respectively. Static and dynamic analyses were conducted, and the performance of the proposed structural system was evaluated and compared with a typical three dimensional reinforced concrete frame system for buildings of the same floor areas and number of floors. Compressive strength capacity of a ceiling panel is determined for gravity loads, while flexural capacity is determined under the effect of wind and seismic loading. It was found that, the strength and serviceability requirements could be easily satisfied for buildings constructed using the three-dimensional panel system. The 3D panel system is superior to that of conventional frame system in its dynamic performance, due to its high stiffness to mass ratio.

코어공명을 이용한 허니콤패널의 흡음율 개선에 관한 연구 (A study on the improvement of sound absorption coefficient of an honeycomb panel by the core resonance)

  • 유영훈
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.46-51
    • /
    • 2008
  • Honeycomb panel has a constructive advantage because it is constructed with a honeycomb core, so it has relatively higher strength ratio to weight. Therefore honeycomb panel has been used as the light weight panels in the high-speed railway technology and high-speed ship like as cruise yachts. Also it has been used in the aircraft and aerospace industry as a structural panel because light weight structure is indispensible in that field of industry. Recently, the honeycomb panel is embossed in the viewpoints of high oil prices as the lightweight panel of the transport machine, however the sound insulation capacity of the honeycomb panel is poorer than those of uniform and another sandwich panels. In this paper a method to improving the sound absorption coefficient of a honeycomb panel Is studied by using the Helmholtz resonator. The sound absorption coefficients for some kinds of honeycomb cores are demonstrated by the normal incident absorption coefficient method.

  • PDF

Nonvolatile memory devices with oxide-nitride-oxynitride stack structure for system on panel of mobile flat panel display

  • Jung, Sung-Wook;Choi, Byeong-Deog;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.911-913
    • /
    • 2008
  • In this work, nonvolatile memory (NVM) devices for system on panel of flat panel display (FPD) were fabricated using low temperature polycrystalline silicon (LTPS) thin film transistor (TFT) technology with an oxide-nitride-oxynitride (ONOn) stack structure on glass. The results demonstrate that the NVM devices fabricated using the ONOn stack structure on glass have suitable switching characteristics for data storage with a low operating voltage, a threshold voltage window of more than 1.8 V between the programming and erasing (P/E) states after 10 years and its initial threshold voltage window (${\Delta}V_{TH}$) after $10^5$ P/E cycles.

  • PDF

Experimental Study on Transient Heating of the Glass Panel in the Infrared Heating Chamber

  • Lee, Kong-Hoon;Kim, Ook-Joong;Ha, Su-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.499-502
    • /
    • 2004
  • The temperature distribution of a glass plate heated in the infrared heating chamber has been investigated. Temperature of the glass panel is measured using a set of thermocouples and the optical pyrometer. Temperatures measured by thermocouples have good agreement with those by the pyrometer. The temperature uniformity of the panel is improved with wall reflectivity, which is one of the important factors to uniformly heat the panel

  • PDF

고정식 집속형 PV모듈 복합패널의 BIPV적용성 검토 (A Study on the Application of Fixed-concentrated PV Module Hybrid Panel for BIPV)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.77-83
    • /
    • 2005
  • The verified thermal efficiency, thermal capacity confirmed the effects of the cooling system. Therefore, it is useful for preventing the PV cell temperature rising when solar radiation accumulates in summer. When adopting a hybrid panel for the BIPV system, the affected areas include the vertical outside walls facing the south, southeast, and southwest on the curtain walls excluding windows. The standards on replace aluminum panel which were the popular exterior material were investigated, Designing practice made sure that it could be manufactured in various sizes, and confirmed the most proper method to install a hybrid panel in the BIPV system.

판넬블록 생산관리를 위한 시뮬레이션 기반 조선생산실행시스템 개발 (Development of simulation-based ship production execution system(SPEXS) for a panel block assembly shop)

  • 이광국;김영훈
    • 한국정보통신학회논문지
    • /
    • 제15권11호
    • /
    • pp.2313-2320
    • /
    • 2011
  • 조선소에서 판넬블록 생산공정은 가장 많은 물량을 처리해야 하는 중요하고 복잡한 공정이 고, 모든 선박 및 해양구조물의 하부는 반드시 판넬블록 생산 공정을 거쳐야 하기 때문에 판넬블록 생산공정은 병목공정으로 평가된다. 공정의 생산성을 극대화하기 위해 본 논문에서는 디지털 선박생산에서 가장 중요한 기술 중의 하나인 시뮬레이션과 최적화기법을 활용하여 조선생산실행시스템(SPEXS)을 개발하였고, 판넬블록조립장 적용사례로 SPEXSPanel을 구축하여 향상된 일정계획을 수립하는 효과를 보였다. 더불어 SPEXS-Panel은 지속적인 개선을 통해 야드 생산성 향상에 도움을 줄 수 있을 것으로 기대된다.

SOP Image SRAM Buffer용 다양한 데이터 패턴 병렬 테스트 회로 (Parallel Testing Circuits with Versatile Data Patterns for SOP Image SRAM Buffer)

  • 정규호;유재희
    • 대한전자공학회논문지SD
    • /
    • 제46권9호
    • /
    • pp.14-24
    • /
    • 2009
  • System on panel 프레임 버퍼를 위한 메모리 셀 어레이와 주변회로가 설계되었다. 또한, system on panel 공정의 낮은 yield를 극복하기 위해, 블럭 단위의 parallel test 방안이 제안되었다. 기존의 메모리 테스트 보다 빠르게 fault detection이 가능하며, 다양한 embedded memory나 일반 SRAM 테스트 분야에도 적용 가능하다. 또한 기존의 다양한 test vector pattern이 그대로 적용될 수 있어 fault coverage가 높고, 최근의 추세인 hierarchical bit line과 divided word line 구조에도 적용될 수 있다.