• Title/Summary/Keyword: system of falling balls

Search Result 4, Processing Time 0.015 seconds

Experiment of Characteristic Diffusion Time of Viscoelastic Fluid by Particle Image Velocimetry (PIV를 이용한 점탄성 유체의 특성 확산시간에 대한 측정)

  • 전찬열
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.4
    • /
    • pp.251-256
    • /
    • 2002
  • The average diffusion time of a polyacrylamide solution was determined by measuring the terminal velocities of the falling balls. The diffusion time increased as the polyacrylamide concentration increased. The PIV (Particle Image Velocimetry) system was employed to visualize the flow phenomena around balls. For a time interval of 30 seconds in the 2000 wppm, velocity vectors were larger than in case of 0 seconds, 40 seconds and 50 seconds in the falling ball. However, in the Newtonian fluid, flow vsualization around balls were performed at both upstream and downstream of the falling ball.

  • PDF

LINER STABILITY OF A PERIODIC ORBIT OF TWO-BALL LINEAR SYSTEMS

  • Chi, Dong-Pyo;Seo, Sun-Bok
    • Journal of the Korean Mathematical Society
    • /
    • v.36 no.2
    • /
    • pp.403-419
    • /
    • 1999
  • We introduce a Hamiltonian system which consists of two balls in the vertical line colliding elastically with each other and the floor. Wojtkowski proved that for the system of two linear balls with a linear potential (with gravity), there is a periodic orbit which becomes linearly stable if m1

  • PDF

An experimental study on the characteristic times of viscoelastic fluids by falling ball viscometer (낙구식 점도계를 이용한 점탄성 유체의 특성시간에 관한 실험적 연구)

  • 전찬열;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.241-250
    • /
    • 1990
  • Characteristic relaxation time and characteristic diffusion time of viscoelastic fluids are determined experimentally by measuring the zero-shear-rate viscosity by falling ball viscometer and the infinite-shear-rate viscosity by capillary tube viscometer. Fluids used in experiments are aqueous solutions of polyacrylamide Separan AP-273 and the polymer concentrations range from 300 to 2000 wppm. A newly designed laser beam and timer system is employed to overcome the difficulty in measuring terminal velocities of the low concentration solutions. Ball removal device is prepared to remove the dropped ball from the bottom of cylinder without disturbing the testing fluid. In order to measure the zero-shear-rate viscosity, densities of hollow aluminium balls are adjusted very close to the densities of testing fluids. Characteristic diffusion time, which is ball viscometer. However, terminal velocity of a needle by falling ball viscometer is not affected by the time interval of dropping needles and characteristic diffusion time is not measured with a dropping needle. Powell-Eyring model predicts the highest values of the characteristic relaxation times among models used for heat transfer experimental works for a given polymer solution. As degradation of a polymer solution continues, the zero-shear-rate viscosity decreases more seriously than the infinite-shear-rate viscosity. Characteristic relaxation times of polymer solutions decreases as degradation continues.

Study on the Piezoelectric Direct Effect of PVDF Film (PVDF 필름의 압전정효과에 관한 연구)

  • 이용국;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.786-790
    • /
    • 2000
  • This paper is concerned on the theoretical and experimental approaches of direct piezoelectric effect in the PVDF film. When a cantilever structure of PVDF film is bended by the external force, electric charges are concentrated on the electrode surface of the film due to the direct piezoelectric effect, and output voltage is induced from the terminals of the film. In this paper, a symbolic equation between the external force and the output voltage was introduced. Moreover, the theoretical output voltages were compared with the experimental results by falling balls, which were agreed well each other. This results can be useful in a warning system of abnormal pulse rate and breathing, and in detecting impact force and/or mechanical energy using bending of PVDF film.

  • PDF