• 제목/요약/키워드: system generator

검색결과 4,056건 처리시간 0.039초

풍력발전 계통연계 변압기의 결선에 따른 배전계통의 고장전류에 관한 연구 (A Study on the Fault Current of Distribution System according to Connection of Wind Turbine Generation Grid-Connected Transformer)

  • 안해준;노경수;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.369-371
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

10 kW급 유체 토크 컨버터를 이용한 풍력발전시스템에 관한 연구 (A Study of the 10 kW-Level Wind Turbine System by Controlled Hydraulic Torque Converter)

  • 장미혜;김동용
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.14-17
    • /
    • 2009
  • In this paper, A generator of existing vertical type wind turbine system is connected to bevel gear. But, the generator of proposed wind turbine system is connected to Hydraulic torque converter. In case of the proposed wind turbine system, is possible to make torque transmission long distance, set up generator somewhere in between the tower or the ground as well as, nacelle weight can be greatly down. Lightweight of nacelle exactly wind direction tracking can be easily also, cost down of established frame structure and generator setting, maintenance, easy and improvement of system stability.

Controller Design for Static Reactive Power Generator in Transmission System

  • Han, B.M.;Soh, Y.C.;Kim, H.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.398-403
    • /
    • 1998
  • This paper describes a controller design for the stator reactive power generator in the transmission system. The controller of static reactive power generator was designed using a mathematical model and non-linear state feedback. The performance of controller was verified using computer simulation with EMTP code and experimental work with scaled-model. The dynamic interaction with a simple power system was also analyzed using both the simulation model and hardware scaled-model. Both simulation and experimental results prove that the controller using PI block and non-linear state feedback offers better performance than the controller using PI block only.

  • PDF

풍력전용 유도 발전기 최적 슬립제어 (Optimal Slip Control of Wind Induction Generator)

  • 최선필;박지호;노태균;김동완;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.317-319
    • /
    • 2002
  • In this study, We proposed high efficiency wind power generator system for induction generator used SVPWM swiching inverter. First, We propose Equivalient Circuit for Induction Generator, it's characteristics equation, and power equation of slip. In addition, we suggest Pick Power fraction Slip control methods, adapted variable wind power system. We study simulation result for the proposed system and output power by slip effect. and we identify SVPWM of suitable wind power system by comparison between SPWM and SVPWM. Consequently, we show that the system control result from variable wind power is suitable.

  • PDF

Design of Fault Tolerant Control System for Steam Generator Using Fuzzy Logic

  • Kim, Myung-Ki;Seo, Mi-Ro
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.321-328
    • /
    • 1998
  • A controller and sensor fault tolerant system jot a steam generator is designed with fuzzy logic. A structure of the : proposed fault tolerant redundant system is composed of a supervisor and two fuzzy weighting modulators. A supervisor alternatively checks a controlled and a sensor induced performances to identify Which Part, a controller or a sensor, is faulty. In order to analyze controller induced performance both an error and a charge in error of the system output an chosen as fuzzy variables. The fuzzy logic jot a sensor induced performance uses two variables : a deviation between two sensor outputs and its frequency, Fuzzy weighting modulator generates an output signal compensated for faulty input signal. Simulations show that the : proposed fault tolerant control scheme jot a steam generator regulates welt water level by suppressing fault effect of either controllers or sensors. Therefore through duplicating sensors and controllers with the proposed fault tolerant scheme, both a reliability of a steam generator control and sensor system and that of a power plant increase even mote.

  • PDF

Study of Large Wind Power Generator with Evaporative Cooling System

  • Wang, Haifeng;Li, Wang;Guo, Hui;Yang, Jie;Gu, Guobiao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.93-97
    • /
    • 2014
  • Evaporative cooling system has the advantage of high cooling performance, good insulation properties, less electrical fault, easy to maintain and high reliability, can meet the requirements of the cooling system in wind power generators. Based on a large number of theoretical researches and engineering practices, we had a comprehensive study of evaporative cooling wind power generator. Studies show that evaporative cooling system has advantage as the cooling system of wind power generator.

Tie Line Constrained Equivalent Assisting Generator Model (TEAG) Considering Forced Outage Rates of Transmission Systems

  • Park, Jaeseok;Tran, Trung-Tinh;Sungrok Kang;Park, Dongwook;Jaeyoung Yoon;Seungil Moon;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.91-99
    • /
    • 2004
  • This paper illustrates a tie line constrained equivalent assisting generator (TEA G) model considering forced outage rates of transmission systems for reliability evaluation of interconnected power systems. Interconnections between power systems can provide improved levels of reliability. It is expected that the TEAG model developed in this paper will prove useful in the solution to problems related to the effect of transmission system uncertainties in the reliability evaluation of interconnected power systems. The characteristics and concept of this TEAG considering transmission systems are described in detail by sample studies on a simple test system.

Performance Improvement of the Linear BLDC Generator in a NASA Deep Space Explorer

  • Lee, Hyung-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.108-113
    • /
    • 2004
  • This paper presents methods to improve performance of the power supply system in a NASA deep space explorer. In the Stirling engine driven reciprocating Brushless DC (BLDC) generator, the accurate position information of the prime mover is important to diagnose the performance of the engine and prevent distortion of the output power. Since sensors to detect the position are fragile and unreliable, and conventional sensorless techniques have drawbacks in the low speed region, a novel sensorless position detection technique for the prime mover has been proposed and verified. Another major issue of the generator for the spacecraft is power density maximization. The mass of the power system is important to the mass of the satellite. Therefore, the components of the spacecraft should be lightweight. Conventional rectification methods cannot achieve the maximum power possible due to non-optimal current waveforms. The optimal current waveform for maximizing power density and minimizing machine size and weight in a nonsinusoidal power supply system has been derived, incorporated in a control system, and verified by simulation work.

독립형 태양광, 풍력, 소형발전기 복합시스템에서 안정적인 전력공급을 위한 컨트롤러에 관한 연구 (The Study on the Controller for Supplying Stably Power with a Stand-Alone Photovoltaic/Wind/Small Generator Hybrid Power Generation System)

  • 최병수;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.48-56
    • /
    • 2012
  • The object of this paper is the controller for supplying stably power in a separate house in which a hybrid electrical storage system with a stand-alone photovoltaic/wind power generation system and a small generator is applied. In the photovoltaic/wind hybrid power system used in the separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. In particular, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to estimate the number of sunless days. Accordingly, it is preferable to build the electrical storage system that numbers of sunshineless days are to be controlled and a shortage amount of the power generation capacity is to be handled by a small generator system. In order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage. Such system needs components including inverters for photovoltaic and wind power generation system, batteries and controllers for automatically driving the small generator, based upon the nature of the stand-alone house, and it is preferable to use the controller having a simpler and higher stability by adopting the all-in-one scheme to facilitate its maintenance.

PMS HILS 구축을 위한 Dual Fuel Generator 모델링 및 시뮬레이션 (Dual Fuel Generator Modeling and Simulation for Development of PMS HILS)

  • 황준태;홍석윤;권현웅;이광국;송지훈
    • 한국정보통신학회논문지
    • /
    • 제21권3호
    • /
    • pp.613-619
    • /
    • 2017
  • 본 논문에서는 PMS(Power Management System) HILS(Hardware In the Loop Simulaition) 가상 제어기 환경 구축을 위하여 디젤과 LNG를 연료로 사용가능한 DF(Dual Fuel) Generator를 MATLAB/SIMULINK 기반으로 모델링을 수행하고 시뮬레이션 결과 모니터링이 가능한 인터페이스를 구현하였다. DF Generator의 주요 구성은 기계적 동력을 공급하는 DF 엔진과 기계적 동력을 받아 전력을 생산 및 공급을 하는 동기발전기가 있다. DF 엔진의 서브모델은 throttle body, intake manifold, torque generation 그리고 mass of LNG and diesel quantity 가 있다. 또한, 단일 용량을 초과하는 전체 부하를 공유하기 위하여 병렬 연결된 DF Generator 와 governor 모델을 이용하여 부하 분담 시스템을 구현하였다. 시뮬레이션 결과와 가상 부하에 따른 예상 결과의 비교를 통해 DF Generator 모델의 신뢰성을 검증하였다.