• Title/Summary/Keyword: system difference

Search Result 11,994, Processing Time 0.039 seconds

Position Measuring System Design using Time Difference of Arrival (송신 신호의 도달 시간차(TDOA)를 이용한 위치 측정 시스템의 구현)

  • Kim, Dong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.394-397
    • /
    • 2001
  • There are several methods of measuring position. For example GPS, AOA, TDOA and using radio camera. In this Paper I used TDOA method in position measuring system. TDOA method uses arrival time difference. In position measuring system, three transfers which is placed in different position transfer signal to receiver in fixed time interval and receiver records arrival time of signal. Because receiver knows idle signal's arrival time, receiver can calculate the difference of the signal's arrival time between idle and real. When we obtain time difference we can know the receiver position by Newton Raphson method.

  • PDF

Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System (바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

Endurance of Pneumatic Valve with a Multi-bender PZT Actuator (적층 벤더형 압전식 공압밸브의 내구 특성)

  • Yun, So-Nam;Park, In-Sub
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

A Proposal of Simultaneous Acquisition Performance Test Method for Telemetry System (원격 측정 시스템 동시계측 성능시험 방법 제안)

  • Park, Yu-kwang;Lee, Woon-moon;Kim, Bok-ki
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.3
    • /
    • pp.218-223
    • /
    • 2020
  • There are communication methods that guarantees real-time and method of performing the simultaneous acquisition through the synchronized multi-channels to improve the reliability of the telemetry system. Such synchronized systems need to be verified to confirm the simultaneous measurement performance of channels. In this paper, we propose a method to measure the time difference between synchronized channels in a telemetry system through simultaneous acquisition performance test. The simulation signal is applied for measurement and the difference between the sampling period and the simulation signal period is defined as the concept of time resolution. The principle of checking the measurement time difference between channels through time resolution was explained. In addition, the proposed principle was verified through simulation in the situation when measurement time difference may occur. And a procedure for identifying a measurement time difference in an actual telemetry system is described.

A Comparison of the Opened Versus Closed-System of Suctioning -In Oxygen Saturation, Vital Signs and Suction Time- (개방형 흡인술과 폐쇄형 흡인술이 인공호흡기 사용 중환자의 산소포화도와 활력징후에 미치는 효과)

  • Seo, Min-Sook;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.141-154
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the difference of change in oxygen saturation, vital signs and suction time taken for the suctioning during endotracheal suctioning performed with closed suction system and with opened suction system. Methods: Data were collected from 31 adult patients with ventilator treatment who were admitted to a university hospital in Seoul and the collection period was from July 1 to November 15, 2005. Oxygen saturation, heart rate, respiration rate and mean arterial pressure were collected immediately prior to the suctioning intervention, during and 1 and 5 minutes after the suctioning from opened suction system and closed suction system. Results: 1) The difference in oxygen saturation was statistically significant in recovery time for oxygen saturation to return to baseline values after suctioning was significantly rapid on closed suction system (p<.05). 2) The difference in heart rate, respiration rate and mean arterial pressure was statistically insignificant 3) The suction time was shorter in closed suction system. Conclusion: Closed suction system is more efficient, as compared with the open suction system in the ventilator treatment.

  • PDF

A Study on the Wet Type Ultrasonic Flow-meter System Development (습식방식의 초음파 유량계 시스템 개발에 관한 연구)

  • Lee Eung-Suk;Kwon Oh-Hoon;Rho Myung-Hwan;Lee Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1638-1644
    • /
    • 2005
  • This paper suggests fur the study on a fluid velocity measuring system using ultrasonic transducer. In general, the time difference method to measure the distance between transducers has been known. In this paper, the practical technology for manufacturing ultrasonic flow meter system is studied using the time difference method. The ultrasonic transducer was designed and manufactured. The transmission and receiving algorithm for ultrasonic signal was studied. The ultrasonic flow measuring system was experimented in laboratory using a water reservoir for verifying the distance measuring accuracy. Finally, it was tested in flow calibration laboratory for the velocity measuring performance. The system, designed in this study, showed 0.3 mm resolution in distance measurement. For precise flow measurement, a high speed triggering algorithm is required for ultrasonic signal receiving.

A Development of Displacement Measurement System using Ultrasonic Sensor (초음파 센서를 이용한 변위 측정 시스템 개발)

  • Kim, Jung-Sup;Kim, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.142-145
    • /
    • 1995
  • This paper is to develop a measurement system of the displacement distance using ultrasonic sensors. Two 400KHz ultrasonic sensors are used for realizing the measurement system, such as one sensor transmits the sine wave and the other sensor receives this wave. The displacement is measured by the phase difference between transmitting and receiving signals. A phase defecter transforms phase difference to voltage. Because the output voltage pattern has nonlinear characteristics, the relations of the voltage and the distance are learned by a neural network. As the results of teaming, the efficiency of measurement system is improved. This system can measure the displacement distance at the accuracy of 1 micrometer level.

  • PDF

Adaptive Interference Cancellation for a Space-time Coded DS-CDMA System in Ending Channels with Arrival Time Difference (도착시간차가 존재하는 페이딩 채널에서 시공간부호화된 DS-CDMA시스템을 위한 적응간섭제거 복합수신기)

  • 이주현;이재흥
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an adaptive interference canceller (AIC) Is applied to the space-time coded DS-CDMA system in fading channels with arrival time difference from multiple transmit antennas In a CDMA system, arrival time difference causes not only inter-antenna and Inter-symbol interference but also multiple-access Interference even in a downlink. To mitigate the effect of the Interferences an AIC and ML decoding joint scheme Is proposed fur a space-time coded DS-CDMA system in which an adaptation process of tile AIC is merged in the Viterbi decoding algorithm. The performance of the proposed receiver is evaluated for the system with two transmit antennas. It is shown that the proposed receiver achieves significant performance improvement over the ML decoding receiver without the AIC

  • PDF

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

Evaluation on Effectiveness of the Compensation System for Reproducing or Interactively Transmitting Works in Libraries (도서관의 저작물 복제.전송 보상금제도 효용성 평가)

  • Hong, Jae-Hyun
    • Journal of Korean Library and Information Science Society
    • /
    • v.42 no.3
    • /
    • pp.351-379
    • /
    • 2011
  • The compensation system for reproducing or interactively transmitting works in libraries has been introduced in 2003. It has passed more than 7 years since this system has been implemented in July 2004. This study investigated current situation of operation on the compensation system for reproducing or interactively transmitting works in libraries. The survey on the effectiveness of the compensation system was conducted to a group of authors and librarians. First, the difference of the effectiveness of the compensation system between a group of authors and librarians was analyzed. In addition, the difference of the effectiveness of the compensation system according to status variable of author group was analyzed. Also the difference of the effectiveness of the compensation system according to status variable of librarian group was analyzed. Finally, this study pointed out the problems of the compensation system and presented the way to improve the problems.