Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석)

  • Jo, Jongmin;Lee, Taejin;Yun, Donghyun;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.

Nonlinear Speed Control of PM Synchronous Motor with Extended Kalman Filter Observer

  • Vu, Nga Thi-Thuy;Jung, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.15-23
    • /
    • 2011
  • This paper proposes a nonlinear speed controller for a permanent magnet synchronous motor (PMSM). In this paper, the load torque is estimated by an extended Kalman filter (EKF) observer because the proposed controller needs its knowledge. To confirm the effectiveness of the proposed control scheme, simulations and experiments are performed under motor parameter variations with a prototype PMSM drive system.

A Study on Performance Improvement of Active Noise Control Using Synchronous Sampling Method (동기화한 이산화법을 이용한 능동소음제어의 성능향상에 관한 연구)

  • Kim, Heung-Seob;Oh, Jae-Eung;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2523-2532
    • /
    • 1994
  • In this paper, active noise control is performed in a duct system using the periodic pulse train which corresponds to the periodic component of noise source as a reference signal. Control algorithm applied in this study is possible to eliminate the acoustic feedback which occurs in the conventional filtered-x and filtered-u LMS algorithm by using electrical reference signal and has the fast adaptation speed with low filter orders by using synchronous sampling method is discussed via computer simulations and experiments of case studies such as frequency modulation, amplitude modulation and frequency differency between source signal and reference signal.

On-line Parameter Estimation of Interior Permanent Magnet Synchronous Motor using an Extended Kalman Filter

  • Sim, Hyun-Woo;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.600-608
    • /
    • 2014
  • This paper presents estimation of d-axis and q-axis inductance of an interior permanent magnet synchronous motor (IPMSM) by using an extended Kalman filter (EKF). The EKF is widely used for control applications including the motor sensorless control and parameter estimation. The motor parameters can be changed by temperature and air-gap flux. In particular, the variation of the inductance affects torque characteristics like the maximum torque per ampere (MTPA) control. Therefore, by estimating the parameters, it is possible to improve the torque characteristics of the motor. The performance of the proposed estimator is verified by simulations and experimental results based on an 11kW PMSM drive system.

SPMSM Mechanical Parameter Estimation Using Sliding-Mode Observer and Adaptive Filter (슬라이딩 모드 관측기와 적응 필터를 이용한 SPMSM 기계 파라미터 추정)

  • Kim, Hyoung-Woo;Choi, Joon-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.33-39
    • /
    • 2019
  • We propose a mechanical parameter estimation algorithm for surface-mounted permanent magnet synchronous motors (SPMSMs) using a sliding-mode observer (SMO) and an adaptive filter. The SMO estimates system disturbances in real time, which contain the information on mechanical parameters. A desirable feature that distinguishes the proposed estimation algorithm from other existing mechanical parameter estimators is that the adaptive filter estimates electromagnetic torque to improve the estimation performance. Moreover, the SMO acts as a low-pass filter to suppress the chattering effect, which enables the smooth output signals of the SMO. We verify the mechanical parameter estimation performance for SPMSM by conducting extensive experiments for the proposed algorithm.

A High Performance Permanent Magnet Synchronous Motor Servo System Using Predictive Functional Control and Kalman Filter

  • Wang, Shuang;Zhu, Wenju;Shi, Jian;Ji, Hua;Huang, Surong
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1547-1558
    • /
    • 2015
  • A predictive functional control (PFC) scheme for permanent magnet synchronous motor (PMSM) servo systems is proposed in this paper. The PFC-based method is first introduced in the control design of speed loop. Since the accuracy of the PFC model is influenced by external disturbances and speed detection quantization errors of the low distinguishability optical encoder in servo systems, it is noted that the standard PFC method does not achieve satisfactory results in the presence of strong disturbances. This paper adopted the Kalman filter to observe the load torque, the rotor position and the rotor angular velocity under the condition of a limited precision encoder. The observations are then fed back into PFC model to rebuild it when considering the influence of perturbation. Therefore, an improved PFC method, called the PFC+Kalman filter method, is presented, and a high performance PMSM servo system was achieved. The validity of the proposed controller was tested via experiments. Excellent results were obtained with respect to the speed trajectory tracking, stability, and disturbance rejection.

Extended Kalman Filter Design for Sensorless Control of IPMSM Drive (IPMSM의 센서리스 운전을 위한 확장 칼만 필터 설계)

  • Jeon, Yong-Ho;Cho, Min-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1681-1690
    • /
    • 2013
  • In this paper, a design of speed and position controller based on the EKF(Extended Kalman Filter) for sensorless control in IPMSM(Interior Permanent Magnet Synchronous Motor) is proposed. The proposed method subdivides the state estimation interval for improving the accuracy of state estimation. and each subdivided interval estimated first order term using Taylor series. The proposed state estimator comparison with the second-order extended Kalman filter reduced calculation amount of a priori estimation. And the simulation results were proved that The accuracy of priori estimation is increased.

A New Controller of Single Phase Active Power Filter Using Rotating Synchronous Frame d-q Transformation (회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기)

  • Kang, Min Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.271-275
    • /
    • 2014
  • A New Single Phase Active Power Filter Controller is proposed using Rotating Synchronous Frame d-q transformation. Instantaneous Active Power is calculated using d-q transformation. Average Value of Instantaneous Active Power is obtained using Low Pass Filter. Because power factor is corrected, source current is in phase with source voltage. Amplitude of source current is calculated using single phase power formula. Reference signal of compensated current of Active power filter is obtained from source current reference signal minus load current. Simulation is performed using hysteresis current controller in proposed new controller. Simulation result shows that because active power filter compensates load current, source current is in phase with source voltage and source current is sinusoidal. And Hilbert transformer is builded using all pass filter.

Dynamic Synchronous Phasor Measurement Algorithm Based on Compressed Sensing

  • Yu, Huanan;Li, Yongxin;Du, Yao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.1
    • /
    • pp.53-76
    • /
    • 2020
  • The synchronous phasor measurement algorithm is the core content of the phasor measurement unit. This manuscript proposes a dynamic synchronous phasor measurement algorithm based on compressed sensing theory. First, a dynamic signal model based on the Taylor series was established. The dynamic power signal was preprocessed using a least mean square error adaptive filter to eliminate interference from noise and harmonic components. A Chirplet overcomplete dictionary was then designed to realize a sparse representation. A reduction of the signal dimension was next achieved using a Gaussian observation matrix. Finally, the improved orthogonal matching pursuit algorithm was used to realize the sparse decomposition of the signal to be detected, the amplitude and phase of the original power signal were estimated according to the best matching atomic parameters, and the total vector error index was used for an error evaluation. Chroma 61511 was used for the output of various signals, the simulation results of which show that the proposed algorithm cannot only effectively filter out interference signals, it also achieves a better dynamic response performance and stability compared with a traditional DFT algorithm and the improved DFT synchronous phasor measurement algorithm, and the phasor measurement accuracy of the signal is greatly improved. In practical applications, the hardware costs of the system can be further reduced.

A Multiband Shunt Hybrid Active Filter with Sensorless Control

  • Kumar S, Surendra;Sensarma, Partha Sarathi
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper proposes a Multiband Shunt Hybrid Active Filter (SHAF) with sensorless control. A plant is modeled in the discrete- time domain and a controller is designed using the Pole shifting law in the polynomial domain. This control approach is very useful for filtering the load harmonics with reduced sensor counts where a low cost solution like SHAF is required. Multiple Synchronous Reference Frames (MSRF) and low pass filters are used to measure the $5^{th}$ and $7^{th}$ harmonic components separately from the load and filter currents. Individual current controllers are designed for the $5^{th}$ and $7^{th}$ harmonic currents. Control is realized in the stationary, three-phase (abc) reference frame. Performance of the controller is validated through simulation, using realistic plant and controller models, as well as experimentally on a full-scale distribution system.