• Title/Summary/Keyword: switching loss

Search Result 1,109, Processing Time 0.025 seconds

An input-buffer ATM switch based on the dynamic change of the threshold for the occupancy of the buffer (버퍼에 설정된 점유 임계치의 동적 변화에 기초한 입력버퍼형 ATM 스위치)

  • Paik, Jung-Hoon;Lim, Chae-Tak
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.19-27
    • /
    • 1999
  • This paper propose a contention resolution policy featuring dynamic change of the threshold for the occupancy of the input buffer for an input buffering ATM switching architecture and its hardware implementation strategy. The strategy is provided with the aim of the simple structure that achieves the reduction of the signal path and the power consumption. The threshold is changed dynamically every time slot based both the arrived of cells and the cell service resulting from the contention resolution. The performance on the cell loss of the proposed policy is performed and compared with the conventional policy under the diverse traffic conditions through both the analysis based ont the Markov chain and the simulation.

  • PDF

Study On The MAC Schedule Technique for WPAN system to alleviate the impact of interference in the presence of WLAN system (WPAN시스템에 미치는 WLAN 시스템의 간섭신호 경감을 위한 MAC schedule 기법에 관한 연구)

  • Kim, Seong-cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2263-2268
    • /
    • 2015
  • This paper describes packet scheduling techniques that can be used to alleviate the impact of interference. The mechanism is consisted of interference estimation and master delay police. Proposed scheduling police is effective in reducing packet loss and delay. Another advantage worth mentioning, are the additional saving s in the transmitter power since packet are not transmitted when channel is bad. This paper gives that scheduling policy works only with data traffic since voice packets need to be sent at fixed intervals. However, if the delay variance is constant and the delay can be limited to a slot, it may be worthwhile to use DM packet for voice.

A Routing Protocol with Fast-Recovery of Failures Using Backup Paths on MANETs (MANET에서 백업경로를 이용한 빠른 경로복구 능력을 가진 라우팅 프로토콜)

  • Thai, Ahn Tran;Kim, Myung-Kyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1541-1548
    • /
    • 2012
  • This paper proposes a new multipath-based routing protocol on MANETs with Fast-Recovery of failures. The proposed protocol establishes the primary and secondary paths between a source and a destination considering the end-to-end packet reception reliability of routes. The primary path is used to transmit messages, and the secondary path is used to recover the path when detecting failures on the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to recover locally the route failure, the proposed protocol can reduce the number of packet loss and the amount of control packets for setting up new paths. The simulation result using QualNet simulator shows that the proposed protocol was about 10-20% higher than other protocols in terms of end-to-end message delivery ratio and the fault recovery time in case of link fault was about 3 times faster than the other protocols.

Analysis of Consumer Value for the Business Model Development of Next Generation IPTV: Mobile IPTV (차세대 IPTV 비즈니스 모델 개발을 위한 소비자 가치 분석: 모바일 IPTV를 중심으로)

  • Shin, Min-Soo;Kim, Sung-Hee;Cho, Cheol-Hye
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1B
    • /
    • pp.60-70
    • /
    • 2011
  • IPTV was introduced as the new growth engine of the broadcasting and telecommunications industry and has experienced a high growth rate as its subscribers exceeded 2 million in early 2010. However there have been some doubts on if the IPTV market will keep current growth drift. One of such suspicions is that IPTV market has not been developed by the competitiveness of IPTV industry itself. In addition, the recent slowdown of subscribers' growth and IPTV players' operating at a loss has been suggested as obstacles to the IPTV market growth. This sort of phenomenon has been brought about by ambiguous proposition of IPTV's own value as well as IPTV service positioning gap. To resolve these problems this study empirically investigates what customers want to get from IPTV service by analyzing switching value of IPTV subscribers. This study also identifies which values must be strategically considered to develop next generation IPTV services, in particular mobile IPTV services. Following the investigation, this study analyzes the possible positioning gap of mobile IPTV. Through this analysis, this study suggests which sort of service values need to be reconciled.

An Analysis and Optimum Design of o Neutral Line Harmonics Eliminating Reactor (중성선 영상고조파 저감용 특수 Reactor 최적설계 연구)

  • Shin, Pan-Seok;Chung, Gyo-Bum;Kim, Han-Deul;Kim, Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.33-41
    • /
    • 2006
  • In the modem power distribution systems, there are lots of zero-phase current harmonics in the neutral power line due to much usages of the controlled switching devices, various semiconductor power converting systems, OA(Office Automation) equipments, PC etc. In order to minimize the current harmonics a zero-phase neutral line current eliminating reactor (NHER) is designed and analyzed its performance using the finite element program. For the design of NHER a program is developed using C++ program. To verify the program a case model(380/220[V], 200[A]) is designed and analyzed by the developed program. As the results of the optimal design, the core loss is reduced by 26[%] with eliminating of the current harmonics. Especially the ninth harmonics is much reduced as compared with the others. When the design of NHER is adapted to the load of the power system, the eliminating effect and efficiency of the device will be much better

Detection of 10-GHz Optical Single-/Double-Sideband Labels Using Fiber-Optic Interleavers (광섬유 인터리버를 이용한 10-GHz 광 단측파대/양측파대 레이블 검출)

  • Park, Kyoung-Deuk;Shin, Jong-Dug;Kim, Boo-Gyoun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7C
    • /
    • pp.652-657
    • /
    • 2007
  • Optical subcarrier-multiplexed (OSCM) labels in optical label switching networks have been detected using interleavers composed of fiber-optic Mach-Zehnder interferometer. 10-GHz optical single-/double-sideband signals generated from dual-electrode Mach-Zehnder intensity modulator have been used as the OSCM labels. In the case of single-sideband signals, the upper-sideband was observed to be suppressed about 16.8 dB compared with the lower-sideband from the optical spectrum measured at the label extraction output. For the case of double-sideband signals, both sidebands appeared with small insertion loss at the interleaver output. Since we used the phase-shift method to generate single-sideband signals, the power level of the single-sideband was higher by 3 dB than that of the double-sidebands.

High Power Cavity Type Tunable Filter Using Switch for 1.5 GHz Band (Switch를 이용한 1.5 GHz 대역 고출력 Cavity 기반 Tunable Filter)

  • Ahn, Sehoon;Lee, Minho;Park, Jongcheol;Jeong, Gyetaek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, the tunable filter based on high power cavity using mechanical switch for 1.5 GHz band is presented. The LPF is inserted to eliminate the spurious wave, coupler is embeded to extract the output power, and then the tunable filter system is configured using mechanical switch. The LPF obtains attenuation over 40 dB between 4 GHz and 12.75 GHz, Coupler is satisfied with coupling value 40 dB and coupling isolation over 55 dB. The tunable filter system using mechanical switch obtains insertion loss 0.88 dB at bypass mode between 1,495.9 MHz and 1,510. 9 MHz, 3.29 dB at fil mode between 1,495.9 MHz and 1,500.9 MHz. It is also satisfied with output power of 132 W at the center frequency 1,498.4 MHz, and switching time below 10 ms.

Multi-Secondary Transformer: A Modeling Technique for Simulation - II

  • Patel, A.;Singh, N.P.;Gupta, L.N.;Raval, B.;Oza, K.;Thakar, A.;Parmar, D.;Dhola, H.;Dave, R.;Gupta, V.;Gajjar, S.;Patel, P.J.;Baruah, U.K.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2014
  • Power Transformers with more than one secondary winding are not uncommon in industrial applications. But new classes of applications where very large number of independent secondaries are used are becoming popular in controlled converters for medium and high voltage applications. Cascade H-bridge medium voltage drives and Pulse Step Modulation (PSM) based high voltage power supplies are such applications. Regulated high voltage power supplies (Fig. 1) with 35-100 kV, 5-10 MW output range with very fast dynamics (${\mu}S$ order) uses such transformers. Such power supplies are widely used in fusion research. Here series connection of isolated voltage sources with conventional switching semiconductor devices is achieved by large number of separate transformers or by single unit of multi-secondary transformer. Naturally, a transformer having numbers of secondary windings (~40) on single core is the preferred solution due to space and cost considerations. For design and simulation analysis of such a power supply, the model of a multi-secondary transformer poses special problem to any circuit analysis software as many simulation softwares provide transformer models with limited number (3-6) of secondary windings. Multi-Secondary transformer models with 3 different schemes are available. A comparison of test results from a practical Multi-secondary transformer with a simulation model using magnetic component is found to describe the behavior closer to observed test results. Earlier models assumed magnetising inductance in a linear loss less core model although in actual it is saturable core made-up of CRGO steel laminations. This article discusses a more detailed representation of flux coupled magnetic model with saturable core properties to simulate actual transformers very close to its observed parameters in test and actual usage.

A Wide Output Range, High Power Efficiency Reconfigurable Charge Pump in 0.18 mm BCD process

  • Park, Hyung-Gu;Jang, Jeong-A;Cho, Sung Hun;Lee, Juri;Kim, Sang-Yun;Tiwari, Honey Durga;Pu, Young Gun;Hwang, Keum Cheol;Yang, Youngoo;Lee, Kang-Yoon;Seo, Munkyo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.777-788
    • /
    • 2014
  • This paper presents a wide output range, high power efficiency reconfigurable charge pump for driving touch panels with the high resistances. The charge pump is composed of 4-stages and its configuration automatically changes based on the required output voltage level. In order to keep the power efficiency over the wide output voltage range, internal blocks are automatically activated or deactivated by the clock driver in the reconfigurable charge pump minimizing the switching power loss due to the On and Off operations of MOSFET. In addition, the leakage current paths in each mode are blocked to compensate for the variation of power efficiency with respect to the wide output voltage range. This chip is fabricated using $0.18{\mu}m$ BCD process with high power MOSFET options, and the die area is $1870{\mu}m{\times}1430{\mu}m$. The power consumption of the charge pump itself is 79.13 mW when the output power is 415.45 mW at the high voltage mode, while it is 20.097 mW when the output power is 89.903 mW at the low voltage mode. The measured maximum power efficiency is 84.01 %, when the output voltage is from 7.43 V to 12.23 V.

A Study of Seamless Power Supply using EDLC on Battery Change of Smartphone (EDLC를 이용한 스마트폰의 배터리 교환 시 연속적 전원 공급에 관한 연구)

  • Choi, Sang-Hun;Lee, Yong-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.61-67
    • /
    • 2015
  • Certainly, we are living in a true mobile society. At the end of 2014, approximately 40million 560thousand people are subscribed to smartphone services in Korea, using more than 2000MB of mobile data per a person. The use of smartphone is expected to increase. Moreover, smartphone moves toward becoming a requisite for modern people. Under the circumstances, high-speed communication services such as LTE provide high quality services anywhere and anytime and, furthermore, the development of high performances of the application makes the life patterns of modern people link directly to smartphone. Almost every day, new creative services are being introduced and the demands of on-line streaming services such as high-performance game and YouTube are increasing day after day. However, although smartphones are getting smarter and high quality services are rapidly growing, consumers still complain about the insufficient usage time caused by the capacity of batteries. In order to solve this problem, this thesis suggests EDLC(Electric Double-Layer Capacitor) uses as a supplemental power supply to keep the continuity of work while switching batteries. Through this approach, the running time of smartphone becomes longer as the number of batteries without power off and the purpose of this study is to maximize the convenience of using smartphone by eliminating the initialization of memories and the loss of time of rebooting while batteries are switched.