Evaluations of load-deformation behavior of soil nail using hyperbolic pullout model

  • Zhang, Cheng-Cheng;Xu, Qiang;Zhu, Hong-Hu;Shi, Bin;Yin, Jian-Hua
    • Geomechanics and Engineering
    • /
    • 제6권3호
    • /
    • pp.277-292
    • /
    • 2014
  • Soil nailing, as an effective stabilizing method for slopes and excavations, has been widely used worldwide. However, the interaction mechanism of a soil nail and the surrounding soil and its influential factors are not well understood. A pullout model using a hyperbolic shear stress-shear strain relationship is proposed to describe the load-deformation behavior of a cement grouted soil nail. Numerical analysis has been conducted to solve the governing equation and the distribution of tensile force along the nail length is investigated through a parametric study. The simulation results are highly consistent with laboratory soil nail pullout test results in the literature, indicating that the proposed model is efficient and accurate. Furthermore, the effects of key parameters, including normal stress, degree of saturation of soil, and surface roughness of soil nail, on the model parameters are studied in detail.

Strength Characteristics of Soil Cement Reinforced by Natural Hair Fiber

  • Son, Moorak;Lee, Jaeyong
    • 한국지반환경공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.17-26
    • /
    • 2018
  • This study systematically examines the changes in the compressive and tensile strength of soil cement reinforced by natural hair fiber, which is regularly produced from human. Extensive experimental tests of various test specimens have been carried out in a laboratory. Several factors are considered, including the soil type, amount of cement, amount of fiber, fiber length, loading type, and curing age. The test results indicate that both the compressive and tensile strengths are significantly affected by the fiber, either increasing or decreasing depending on the conditions. The increase in tensile strength is significant in the sand-based soil cement due to the tensile resistance of the fiber which is interlocked with the surrounding soil or cement particles. The natural fiber provides a larger strain to failure due to its extensibility, which allows greater deformation. Based on the test results, natural hair fibers can be an effective and environmentally friendly way to improve soil ground subjected to tensile loading, such as an embankment slope, road subgrade, or landfill, thus reducing the cost for cement and waste treatment. The study results provide a useful information of better understanding the mechanical behavior of natural hair fiber in soil cement and the practical use of waste materials in civil engineering. The findings can be practically applied for improving earth structures under tensile loading.

Microbial Amelioration of Acid Mine Drainage Impaired Soil using the Bacterial Consortia of Klebsiella sp. and Raoultella sp.

  • Park, Seon Yeong;Lee, Gi Won;Kim, Chang Gyun
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권1호
    • /
    • pp.34-44
    • /
    • 2021
  • Acid mine drainage (AMD) resulting from pyrite oxidation in mining areas, subsequently leads to soil acidification accompanied by lowering pH and high concentration of metals and metalloids in its surrounding environment. Regarding to this, the microbial amelioration has been considered as a promising option for a more cost-effective and eco-friendlier countermeasure, compared to the use of alkaline chemicals. This study was aimed to evaluate influencing factors in microbially-mediated amelioration of acidic soil spiked by simulated AMD. For this, microcosm experiments were conducted by acid-neutralizing bacterial consortium (dominated by Klebsiella sp. and Raoultella sp.) under the various conditions of AMD spikes (0-2,500 mg SO42-/L), together with acidic mine soil (0-100 g) or sphagnum peat (0-5 g) in the 200 mL of nutrient medium. The employed bacterial consortium, capable of resisting to high level of sulfate concentration (up to 1,500 mg SO42-/L) in low pH, generated the ammonium while concomitantly reduced the sulfate, subsequently contributing to the effective soil stabilization with an evolution of soil pH up to neutral. Furthermore, it demonstrates that suitable condition has to be tuned for successful microbial metabolism to facilitate with neutralization during practical application.

교통량별 가로변 토양특성 및 타이어 마모 입자(TWPs) 분석 (Analysis of Roadside Soil Characteristics and Tire Wear Particles(TWPs) According to Traffic Volume)

  • 이선영;주진희;윤용한
    • 한국환경과학회지
    • /
    • 제32권9호
    • /
    • pp.627-634
    • /
    • 2023
  • Tire wear particles(TWPs), regarded as a microplastic, is generated in significant quantities each year and exist in various spaces and have a negative impact on the surrounding environment. Particularly, roadside environments fall within the direct influence of TWPs, necessitating proactive investigation for contamination management and response. Therefore, this study aimed to investigate the soil acidity and electrical conductivity(EC) and TWPs in the roadside soil of six sites based on traffic volume. The analysis revealed that the soil in all sites exhibited subacidity, and there were no significant differences in EC. Microscopic and FT-IR analysis revealed the presence of microscopic particles in soil samples that exhibited common visual characteristics of TWPs. In the road with the highest traffic volume, 48,300 TWPs were detected per unit area. Furthermore, a proportional relationship between traffic volume and TWPs particles was established. However, influences other than traffic volume on TWPs particle count within the soil were observed. Therefore, for the management of TWPs contaminated roadside soil, a proactive response is necessary in areas with high traffic volumes. However, in order to effectively address the factors contributing to the generation and dispersion of TWPs, further research is required with a multidimensional approach.

동적기본해의 역FFT에 의한 비선형 지반-말뚝-구조계의 시간영역 지진응답 해석 (Time Domain Seismic Response Analysis of Nonlinear Soil-Pile-Structure Interaction System using Inverse FFT of Dynamic Fundamental Solution)

  • 김문겸;임윤묵;조석호;박종헌;정대희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.125-132
    • /
    • 2002
  • In this study, a numerical method is developed for nonlinear analysis for soil-pile-structure interaction system in time domain. Finite elements considering material nonlinearity are used for the near field and boundary elements for the far field. In the near field, frame elements are used for modeling a pile and plane-strain elements for surrounding soil and superstructure. In. the far field, boundary element formulation using the dynamic fundamental solution is adopted and coupled with the near field. Transformation of stiffness matrices of boundary elements into time domain is performed by inverse FFT. Stiffness matrices in the near field and far field are coupled. Newmark direct time integration method is applied. Developed soil-pile-structure interaction analysis method is verified with available literature and commercial code. Also, parametric studies by developed numerical method are performed. And seismic response analysis is performed using actual earthquake records.

  • PDF

봉형접지전극 주변에서 토중방전현상에 대한 실험적 고찰 (Experimental investigations of Breakdown Phenomena in Soils in the vicinity of Ground rod)

  • 이복희;김병근;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.279-282
    • /
    • 2005
  • Morden electronic equipments are becoming very important in information oriented society, but they are vulnerable to lightning surges. Soil resistivity in the vicinity of grounding electrodes my be affected by the current flowing from the grounding electrodes into the surrounding soil. Electrical conduction in soils depends on the grain size, compactness, and variability of the grain sizes. When a high current is injected into the soil, and the breakdown phenomenon occur. In the present work, Electrical behaviors related to discharge in soils were investigated. The breakdown voltages in soil were lower than that sparkover voltage in air. The breakdown voltage in the gravel layer is relatively low, and the breakdown was caused by the flashover through the surface of gravels

  • PDF

SCP 복합지반의 응력전이거동 해석 (Analysis of Stress Transfer Mechanism of SCP-Reinforced Composite Ground)

  • 김윤태;박현일;이형주;김상규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.227-234
    • /
    • 2004
  • Sand compaction pile (SCP) method is composed of compacted sand pile inserted into the soft clay deposit by displacement method. SCP-reinforced ground is composite soil which consists of the SCP and the surrounding soft soil. When a surcharge load is applied on composite ground, time-dependent behavior occurs in the soft soil due to consolidation according to radial flow toward SCP and stress transfer also takes place between the SCP and the soft soil. This paper presents the numerical results of cylindrical composite ground that was conducted to investigate consolidation characteristics and the stress transfer mechanism of SCP-reinforced composite ground. The results show that the consolidation of soft clay has a significant effect on the stress transfer mechanism and stress concentration ratio of composite ground

  • PDF

소일네일링 구조물의 수치해석 (Numerical Analysis of Soil Nail System)

  • 유남재;김영길;박병수;이종호
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.115-125
    • /
    • 1999
  • Current design and analyzing methods about soil nailing structures, developed on the basis of results obtained from experiments in laboratory or in field and numerical analyses, have applied different interaction mechanisms between the reinforced nails and the surrounding ground, and this different safety factors against failure have been obtained. They might be proper approached if the assumptions about rigidity of nails and ground conditions are met with actual conditions occurred in field. Otherwise, they would result in designing on analyzing in inappropriate ways so that it is needed to evaluate the validity of them. Therefore, overall behavior and failure mechanism about soil nailing system were investigated by performing numerical method. Using a finite element analysis, parametric studies were made to examine the importance of the various parameters and their effects on the soil nailing system. The numerical technique of FEM, implemented with Hyperbolic constitutive model, was also used to analyze the test results.

  • PDF

Some practical considerations in designing underground station structures for seismic loads

  • Gu, Jianzhong
    • Structural Engineering and Mechanics
    • /
    • 제54권3호
    • /
    • pp.491-500
    • /
    • 2015
  • Under seismic loading, underground station structures behave differently from above ground structures. Underground structures do not require designated energy dissipation system for seismic loads. These structures are traditionally designed with shear or racking deformation capacity to accommodate the movement of the soil caused by shear waves. The free-field shear deformation method may not be suitable for the design of shallowly buried station structures with complex structural configurations. Alternatively, a station structure can develop rocking mechanisms either as a whole rigid body or as a portion of the structure with plastic hinges. With a rocking mechanism, station structures can be tilted to accommodate lateral shear deformation from the soil. If required, plastic hinges can be implemented to develop rocking mechanism. Generally, rocking structures do not expect significant seismic loads from surrounding soils, although the mechanism may result in significant internal forces and localized soil bearing pressures. This method may produce a reliable and robust design of station structures.

크로스홀 탄성파 시험을 이용한 쇄석다짐말뚝의 시공직경 검측 (Logging for Diametric Variation of Granular Compaction Pile Using Crosshole Seismic Tests)

  • 박철수;정재우;김학성;김은정;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1415-1426
    • /
    • 2008
  • Stone columns, locally called "GCP (granular compaction pile)" can be used to improve strength and resistance against lateral movement of a foundation soil like rigid piles and piers. Also installation of such a discrete column facilitates drainage, and densifies and reinforces the soil in the sense of ground improvement. The integrity of the GCP has been indirectly controlled with the records of each batch including depth and the quantity of stone filled. An integrity testing was attempted using crosshole S-wave logging. The method is conceptionally same as the crosshole sonic logging (CSL) for drilled piers. The only and critical difference is that S-wave should be used in the logging, because P-wave velocity of the stone column is less than that of ground water. The crosshole sonic logger does not have the capability to measure S-wave propagating through the skeleton of crushed stone. An electro-mechanical source, which can generate either P- or SH-waves, and a 1-D geophone were used to measure SH-waves. Two 76mm diameter cased boreholes were installed 1 meter apart across the nominal 700mm diameter stone column. At every 10cm of depth, shear wave was measured across the stone column. One more borehole was also installed 1 meter outward from the one of the above boreholes to measure the shear wave profile of the surrounding soil. The diametric variation of the stone column with respect to depth was evaluated from the shear wave arrival times across the stone column, and shear wave velocities of crushed stone and surrounding soil. The volume calculated with these variational diameters is very close to the actual quantity of the stone filled.

  • PDF