• Title/Summary/Keyword: surplus energy

Search Result 140, Processing Time 0.029 seconds

Economic Feasibility Analysis for P2G Using PEM Water Electrolysis (PEM 수전해를 이용한 P2G에 대한 경제적 타당성 분석)

  • JEONG, SEONJU;CHOI, NAK HEON;MOON, CHANGHWAN;MOON, SANGBONG;LIM, HANKWON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.231-237
    • /
    • 2017
  • With worldwide efforts to increase the portion of renewable energy for $CO_2$ reductions, a lot of attention has been paid to P2G (power-to-gas) in Europe and Japan to efficiently utilize the surplus electricity. In this paper, economic feasibility analysis has been carried out for P2G using PEM water electrolysis by reflecting current economic status in Korea. In addition, efficiency and electricity price required to be competent in Korean market were provided. Based on cash flow diagrams, unit production costs for $H_2$ and $CH_4$ were estimated and profitability of P2G using PEM water electrolysis was analyzed.

Performance Evaluation and Optimization of Hydrogen Liquefaction Process Using the Liquid Air for Pre-Cooling (액화공기(Liquid Air) 예냉기반 수소액화공정 성능 해석 및 최적화)

  • PARK, SUNGHO;AHN, JUNKEON;RYU, JUYEOL;KO, AREUM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.490-498
    • /
    • 2019
  • The intermittent electric power supply of renewable energy can have extremely negative effect on power grid, so long-term and large-scale storage for energy released from renewable energy source is required for ensuring a stable supply of electric power. Power to gas which can convert and store the surplus electric power as hydrogen through water electrolysis is being actively studied in response to increasing supply of renewable energy. In this paper, we proposed the novel concept of hydrogen liquefaction process combined with pre-cooling process using the liquid air. It is that hydrogen converted from surplus electric power of renewable energy was liquefied through the hydrogen liquefaction process and vaporization heat of liquid hydrogen was conversely recovered to liquid air from ambient air. Moreover, Comparisons of specific energy consumption (kWh/kg) saved for using the liquid air pre-cooling was quantitatively conducted through the performance analysis. Consequently, about 12% of specific energy consumption of hydrogen liquefaction process was reduced with introducing liquid air for pre-cooling and optimal design point of helium Brayton cycle was identified by sensitivity analysis on change of compression/expansion ratio.

Hydrogen Production from Water Electrolysis Driven by High Membrane Voltage of Reverse Electrodialysis

  • Han, Ji-Hyung;Kim, Hanki;Hwang, Kyo-Sik;Jeong, Namjo;Kim, Chan-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.302-312
    • /
    • 2019
  • The voltage produced from the salinity gradient in reverse electrodialysis (RED) increases proportionally with the number of cell pairs of alternating cation and anion exchange membranes. Large-scale RED systems consisting of hundreds of cell pairs exhibit high voltage of more than 10 V, which is sufficient to utilize water electrolysis as the electrode reaction even though there is no specific strategy for minimizing the overpotential of water electrolysis. Moreover, hydrogen gas can be simultaneously obtained as surplus energy from the electrochemical reduction of water at the cathode if the RED system is equipped with proper venting and collecting facilities. Therefore, RED-driven water electrolysis system can be a promising solution not only for sustainable electric power but also for eco-friendly hydrogen production with high purity without $CO_2$ emission. The RED system in this study includes a high membrane voltage from more than 50 cells, neutral-pH water as the electrolyte, and an artificial NaCl solution as the feed water, which are more universal, economical, and eco-friendly conditions than previous studies on RED with hydrogen production. We measure the amount of hydrogen produced at maximum power of the RED system using a batch-type electrode chamber with a gas bag and evaluate the interrelation between the electric power and hydrogen energy with varied cell pairs. A hydrogen production rate of $1.1{\times}10^{-4}mol\;cm^{-2}h^{-1}$ is obtained, which is larger than previously reported values for RED system with simultaneous hydrogen production.

Analysis of the Economic Impact of the Change in Congestion Management in the Korean Electricity Market (송전 혼잡처리방법 변경이 시장 참여자 수익에 미치는 영향 분석)

  • Joo, Sung-Kwan;Kim, Ji-Hui;Moon, Guk-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.134-140
    • /
    • 2008
  • A switch in congestion management nile in an electricity market may have positive or negative impact on the surplus of a market participant. As a number of wholesale electricity markets around the world either have already adopted or plan to implement Locational Marginal Pricing (LMP) for energy and congestion management, it is necessary to study the economic impact of a change in congestion management in the Korean electricity market. However, the impact of congestion management on consumer costs and generator surplus has not been studied for the electricity market in Korea. This paper examines how a change in congestion management affects consumer costs and generator surplus in the Korean electricity market.

Advanced FEC Scheme Considering Energy and Link-Quality for Solar-Powered WSNs (태양 에너지 기반 무선 센서 네트워크에서 에너지와 링크 품질을 고려한 향상된 FEC 기법)

  • Gil, Gun Wook;Kang, Minjae;Noh, Dong Kun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.4
    • /
    • pp.83-88
    • /
    • 2020
  • In Solar-powered wireless sensor networks(SP-WSN), the battery is periodically charged, so the best use of harvested energy is more important, rather than minimizing energy consumption. Meanwhile, as is well known, the reliability of communication between sensor nodes is very limited due to the resource-constraint of sensor nodes. In this paper, we propose an advanced FEC (forward error correction) scheme which can give SP-WSN more reliability for communication. Firstly, the proposed scheme uses energy modeling to calculate the amount of surplus energy which can be utilized for extra operations, and then determines the number of additional parity bits according to this amount of surplus energy. At the same time, link quality modeling calculates the optimal parity bits for error recovery in the current data communication environment. Finally, by considering these two parity sizes, it is possible to determine the optimal parity size that can maximize the data reliability without affecting the node black out. Performance verification was performed by comparing the amount of data collected at the sink and the number of outage nodes with other schemes.

The Optimum Control Study for Improving Efficiency of the Small Hydropower Generation in Water Pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with 00 hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

Molecular Mechanism of Adipocyte Differentiation and It′s Impact on Obesity

  • Seo, Jong-Bae;Lee, Yun-Suk;Cho, Hye-Jin;Kim, Jae-Bum
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.11-14
    • /
    • 2003
  • Adipocyte development has an impact on human health issues mainly through the association of obesity with Type II diabetes, hyperlipidemia, hypertension and cardiovascular disorders. Obesity results from excessive food intake and reduced energy expenditure, and such surplus energy is stored in adipose tissue.

  • PDF

Maximization of Poly-$\beta$-Hydroxybutyrate Accumulation by Potassium Limitation in Methylobacterium organophilum and Its Related Metabolic Analysis

  • Kim, Seon-Won;Kim, Pil;Kim, Jung-Hoe
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.2
    • /
    • pp.140-146
    • /
    • 1999
  • When methanol was the sole carbon source, Methylobacterium organophilum NCIB 11278, a facultative methylotroph, accumulated Poly-$\beta$-hydroxybutyrate (PHB) as 59% (w/w) of dry cell weight under potassium limitation, 37% under sulfate limitation, and 33% under nitrogen limitation. Based on a stoichiometric analysis of PHB synthesis from methanol, it was suspected that PHB synthesis is accompanied by the overproduction of energy, either 6-10 ATP and 1 $FADH_2$ or 6 ATP and 3 NADPH to balance the NADH requirement, per PHB monomer. This was confirmed by observation of increased intracellular ATP levels during PHB accumulation. The intracellular ATP with limited potassium, sulfate, and ammonium increased to 0.185, 0.452, and 0.390 $\mu$moles ATP/g Xr (residual cell mass) during PHB accumulation, respectively. The intracellular ATP level under potassium limitation was similar to that when there was no nutrient limitation and no PHB accumulation, 0.152- 0.186 $\mu$moles ATP/g Xr. We propose that the maximum PHB accumulation observed when potassium was limited is a result of the energy balance during PHB accumulation. Microorganisms have high energy requirements under potassium limitation. Enhanced PHB accumulation, in ammonium and sulfate limited conditions with the addition of 2,4-dinitrophenol, which dissipates surplus energy, proves this assumption. With the addition of 1 mM of 2,4-dinitrophenol, the PHB content increased from 32.4% to 58.5% of dry cell weight when nitrogen limited and from 15.1 % to 31.0% of dry cell weight when sulfate limited.

  • PDF

Development Status of the Regeneration Inverter System for Energy Saving in DC Electric Railway (전철시스템의 에너지절약 회생인버터시스템 개발 현황)

  • Kim, Yong-Ki;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1473-1478
    • /
    • 2007
  • In the respect of energy saving and reusing, it is necessary to reduce greenhouse gases emission and to enhance the operation efficiency in electric railway system. Recently, as the power electronics technologies are advanced, some countries have focused on the regenerative inverter to use regeneration energy on each line. When the electric tractions are stopped or slowed down, it is useful to supply the surplus energy to the power source by regenerative system, which increases its energy efficiency. Also, the generated energy can be supply to other tractions or equipments inside traction. Thus, it may help reduce construction cost of additional power plants. The purpose of this study is to describe the development status of the regenerative inverter system which suppress extra DC-line voltage and regenerate the energy instead of using a resister.

  • PDF