• Title/Summary/Keyword: surplus energy

Search Result 140, Processing Time 0.051 seconds

Performance Simulation of BOG Reliquefaction System for Dual Fuel Engine of LNG Carrier (LNG 선박 Dual Fuel 엔진용 BOG 재액화 시스템의 성능 시뮬레이션)

  • Lee, Sang-Hoon;Shin, You-Hwan;Lee, Yoon-Pyo;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.148-153
    • /
    • 2008
  • As the oil price is dramatically jumping up, the consumption of LNG is rapidly expanding and the size of LNG carriers becomes bigger. For LNG ships, the application of DF (Dual-Fuel) engines gradually increases because of high efficiency, which alternatively use diesel or BOG (Boil-Off Gas) from cargo tank as a fuel. The surplus BOG from LNG cargo tank should be exhausted by GCU or liquefied through the BOG reliquefaction system and returned back. This study focused into its operational characteristics through the process simulation using HYSYS and discussed details on the influence of the variations of some operational parameters such as a distribution ratio by the change of fuel mass flow into the DF engine.

  • PDF

DC-DC Converter for Integrated Voltage Control Method (전압 적분 제어법에 의한 DC-DC 컨버터)

  • 이현우;서기영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.10
    • /
    • pp.1590-1597
    • /
    • 1993
  • Power conversion system generally requires bidirectional converter. A storage energy of reactor is suppressed by regeneration of surplus electic energy in converter to power source. When an electric isolation in the power conversion system is required. the most suitable position for the isolation is the DC-Link part. A transformer in the DC part is minimized because of high repetition frequency. This paper proposes that power conversion system becomes bidirectional DC-DC converter with electric isolation by intergrated voltage control method. It is intergrated voltage control that makes system construciton simple, has control errow little quantity ans gets output response Quick. And the power-switches which should be operated is selected automatically without a detection of the current-direction.

  • PDF

Water Supply Stability Analysis using Reliability Indices for Water Distribution Network (신뢰도 지수를 활용한 상수관망의 용수공급 안정성 분석)

  • Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.65-65
    • /
    • 2017
  • 상수관망 시스템(Water Distribution System, WDS)은 원활한 용수 공급을 위해 구축된 사회기반시설물로써, 물 공급절차에 따라 그 구성요소를 공급원, 공급 경로, 수요지 등의 범주로 구분할 수 있다. 원활한 물 공급이란 수요지에서 요구하는 수량과 압력 수준을 충족시키는 것을 의미하며, 따라서 상수관망의 용수공급능력은 요구 수량 및 압력과 실제 공급 결과를 비교함으로써 가늠할 수 있다. 과거에는 두 가지 기준을 별도로 산정하여 이를 평가하였으나, 유량과 압력을 함께 고려할 수 있는 에너지 기반의 평가 방법이 제시되면서 시스템 내 에너지 분포를 정량화하여 시스템의 용수공급능력을 평가하는 연구가 주목받고 있다. 세계적으로 많은 연구자들은 시스템 내 에너지 흐름 상태를 정량화함으로써 다양한 형태의 상수관망의 신뢰도지수(Reliability Index)를 제안한 바 있다. 이 때, 대부분의 신뢰도 지수 연구에서는 수요지에 공급된 에너지를 기본적으로 유지해야 하는 최소요구 에너지(Required Energy)와 비상 상황에 대응하기 위한 잉여 에너지(Surplus Energy)로 구분하고 있으며, 잉여 에너지를 상수관망의 공급 안정성을 나타내는 핵심 요소로 활용하고 있다. 확보된 잉여 에너지는 비상시 최소요구 에너지를 대체하는 개념에서 복원력으로 표현되어, 잘 알려진 Resilience Index(RI)를 비롯해 많은 복원력 지수가 존재한다. 본 연구에서는 복원력 지수를 포함한 세 가지의 신뢰도 지수를 적용하여 상수관망의 용수공급 상황 변화에 따른 시스템의 안정성을 분석하였다. 특히, 절점별 복원력 지수를 산정하고 그 분포를 공간적으로 도시하여 파악함으로써, 비상시 효율적인 운영을 위한 판단기준으로써 신뢰도 지수를 폭 넓게 활용할 수 있음을 제시하였다.

  • PDF

Assessment of Energy Self-sufficiency Ratio Based on Renewable Market Potentials for Unit of Local Government (기초지방자치단체별 보급 가능한 재생에너지 시장잠재량을 이용한 에너지 자립률 평가)

  • Kim, Jin-Young;Kang, Yong-Heack;Cho, Sangmin;Yun, Changyeol;Kim, Chang Ki;Kim, Ha-Yang;Lee, Seung Moon;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.137-151
    • /
    • 2019
  • This study estimated the available renewable market potential based on Levelized Cost Of Electricity and then assessed the renewable derived energy self-sufficiency for the unit of local government in South Korea. To calculate energy self-sufficiency, 1 km gridded market renewable generation and local government scale of final energy consumption data were used based on the market costs and statistics for the recent three years. The results showed that the estimated renewable market potentials were 689 TWh (Install capacity 829 GW, 128 Mtoe), which can cover 120% of power consumption. 55% of municipalities can fully replace the existing energy consumption with renewable energy generation and the surplus generation can compensate for the rest area through electricity trade. However, it was confirmed that, currently, 47% of the local governments do not fully consider all renewable energy sources such as wind, hydro and geothermal in establishing 100% renewable energy. The results of this study suggest that energy planning is decentralized, and this will greatly contribute to the establishment of power planning of local governments and close the information gap between the central government, the local governments, and the public.

Environmental Stress Strategies for Stimulating Lipid Production from Microalgae for Biodiesel (바이오디젤용 지질 생산을 위한 미세조류 배양에서 환경 스트레스 조건의 활용 전략)

  • Kim, Garam;Mujtaba, Ghulam;Rizwan, Muhammad;Lee, Kisay
    • Applied Chemistry for Engineering
    • /
    • v.25 no.6
    • /
    • pp.553-558
    • /
    • 2014
  • Microalgae are a promising alternative feedstock for biodiesel production because their growth rates and oil contents are higher than those of conventional energy crops. Microalgal lipid is mainly triacylglyceride that can be converted to biodiesel as fatty acid methyl esters through trans-esterification. In this paper, the influence of several important lipid inducing factors such as nutrient limitation and changes in salinity and metallic components in microalgae and their potential strategies to be used for biodiesel production are reviewed. Depending upon strains/species that we use, microalgae react to stresses by producing different amount of triacylglyceride and/or by altering their fatty acids composition. Although the most widely applied method is the nitrogen starvation, other potential factors, including nutrient surplus conditions and changes in salinity, pH, temperature and metal concentrations, should be considered to increase biodiesel productivity.

A Routing Protocol for Assuring Scalability and Energy Efficiency of Wireless Sensor Network (WSN의 확장성과 에너지 효율성을 보장하는 라우팅 프로토콜)

  • Jeong, Yoon-Su;Kim, Yong-Tae;Park, Gil-Cheol;Lee, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.105-113
    • /
    • 2008
  • While the wireless sensor network has a strong point which does not have effect on whole activities of network even though neighboring sensor nods fail activities of some sensor nod or make some functions disappear by the characteristic of similar information detection, it has problems which is slowing down of wireless medium, transfer character with severe error, limited power supply, the impossibility of change by optional arrangement of sensor nods etc. This paper proposes PRML techniques which performs the fittest course searching process to reduce power consumption of entire nods while guarantees the scalability of network organizing sensor nods hierarchically. The proposed technique can scatter the load of cluster head by considering the connectivity with surplus energy of nod and reduce the frequency of communication among the nods. As a result of the analysis in comparison with LEACH-C and HEED technique, PRML technique get efficiency of average 6.4% in energy consuming respect of cluster head, efficiency of average 8% in entire energy consuming respect, and more efficiency of average 7.5% in other energy consuming distribution of network scalability than LEACH-C and HEED technique.

  • PDF

Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES (구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델)

  • Lee, Seung Jun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.99-120
    • /
    • 2017
  • In SS branch of Korea District Heating Corporation, Combined Heat & Power power plant with 99MW capacity and 98Gcal / h capacity is operated as a district electricity business. In this region, it is difficult to operate the generator due to the problem of surplus heat treatment between June and September due to the economic recession and the decrease in demand, so it is urgent to develop an economical energy new business model. In this study, we will develop an optimized operation model by introducing a renewable energy hybrid system based on actual operation data of this site. In particular, among renewable energy sources, fuel cell (Fuel Cell) power generation which can generate heat and electricity at the same time with limited location constraints, photovoltaic power generation which is representative renewable energy, ESS (Energy Storage System). HOMER (Hybrid Optimization of Multiple Energy Resources) program was used to select the optimal model. As a result of the economic analysis, 99MW CHP combined cycle power generation is the most economical in terms of net present cost (NPC), but 99MW CHP in terms of carbon emission trading and renewable energy certificate And 5MW fuel cells, and 521kW of solar power to supply electricity and heat than the supply of electricity and heat by 99MW CHP cogeneration power, it was shown that it is economically up to 247.5 billion won. we confirmed the results of the improvement of the zone electricity business condition by introducing the fuel cell and the renewable energy hybrid system as the optimization process model.

The Operation Characteristic of the LED Taxi Light for Wavelength According to Meteorological Changes for Hybrid System Using a ESS (하이브리드 시스템의 ESS를 이용한 기상변화의 파장별 LED 항공유도등 동작특성)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong- Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.4
    • /
    • pp.265-274
    • /
    • 2016
  • In this study, the system was composed of the booster chopper and the power converter, which is a pulse width modulation (PWM) voltage inverter using a hybrid power generation system solar cell energy and wind force, Furthermore, in order to compensate the PWM voltage type inverter was linked with the general commercial power source, and through a normal operation of energy storage system (ESS), the system operated the LED Taxi Light by Wavelength according to Meteorological Changes at the airport in an efficient manner. The performance of the system was compared with the solar cell characteristics specification. In addition, for phase synchronization with the PWM voltage type inverter, the grid voltage was detected so as to operate the grid voltage and inverter output in the same phase and to connect the surplus electric power with the system. Finally, by developing a control circuit at the same time from which an excellent dynamic characteristics can be obtained through applying to the airport runway taxi light, it was concluded that a variety of taxi light can be pursued.

A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction (온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구)

  • Lee, Wongoo;KIM, Kang-Won;KIM, Balho H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • ESS(Energy Storage System) is an important source that keeps power supply stable and utilizes electricity efficiently. For example, ESS contributes to resolve power supply imbalance, stabilize new renewable energy output and regulate frequency. ESS is predicted to be expanded to 55.9GWh of installed capacity by 2023, which is 30 times more than that of 2014. To raise competitiveness of domestic ESS industry in this increasing world market, we have disseminated load-shift ESS for continuous power supply imbalance with FR ESS, and also necessity to secure domestic track record is required. However in case of FR ESS, utility of installing thermal power plant is generally generated within 5% range of rated capacity, so that scalability of domestic market is low without dramatic increase of thermal power plant. Necessity of load-shift ESS dissemination is also decreasing effected by surplus backup power securement policy, raising demand for new dissemination model. New dissemination model is promising for $CO_2$ reduction effect in spite of intermittent output. By stabilizing new renewable energy output in connection with new renewable energy, and regulating system input timing of new renewable energy generation rate, it is prospected model for 'post-2020' regime and energy industry. This research presents a policy alternatives of REC multiplier calculation method to induce investment after outlining PV-connected ESS charge/discharge mode to reduce GHG emission, This alternative is projected to utilize GHG emission reduction methodology for 'Post-2020' regime, big issue of new energy policy.

A study on the introduction of organic waste-to-energy incentive system(III): Preparation of an incentive system for biogasification (proposal) (유기성폐자원에너지 인센티브제도 도입방안 연구(III): 바이오가스화 인센티브제도(안) 마련)

  • Moon, Hee-Sung;Kwon, Jun-Hwa;Lee, Won-Seok;Lee, Dong-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.4
    • /
    • pp.87-97
    • /
    • 2021
  • This study was conducted to prepare an incentive system (proposal) for the activation of waste-to-energy. Weights for each type of energy use were prepared by conducting prior research and economic analysis. In addition, the waste-to-energy incentive (proposal) was calculated in consideration of energy efficiency for each type of energy use. As a result of economic analysis of 11 biogasification facilities, the B/C value was found to be very diverse, ranging from 0.16 to 1.69. In terms of benefits, imports of waste treatment import fees were very high at 68.4 to 99.3% of the total, and four facilities with a surplus (+) or higher in the management balance. In order to convert energy consumption into units of sales volume, 0.58 Nm3/KW for power generation, 0.17 Nm3/kg for steam, and 1.00 Nm3/Nm3 for external supply were calculated using the 'scale factor'. The 'weight factor' was calculated as 0.249 for power generation, 0.656 for steam, and 0.806 for external supply, respectively, by use type.