• Title/Summary/Keyword: surface treatment system

Search Result 1,232, Processing Time 0.036 seconds

Seasonal Variation of Picoplankton Community in Lake Juam (주암호에서 미세조류의 계절적 군집 변화)

  • Cheong, Cheong-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.3
    • /
    • pp.271-277
    • /
    • 2010
  • The purpose of this study is to investigate the seasonal variation of picoplankton community in Lake Juam depending on the change of physico-chemical factors such as rainfall, water depth, DO and pH. The concentration of chlorophyll-a was most high as 18.03 mg/$m^3$ in July when the rainfall and water temperature were highest. The concentration was gradually decreased in October, April and that of January was decreased most low as 1.86 mg/$m^3$. The highest concentration of the Chl-a was shown at 2 and 5 m of water depth than surface, and the concentration was gradually decreased when the water depth becomes deep. Overall, microplankton was the highest rate as 33.9~54.2%, nanoplankton was 24.3~30.5% and picoplankton was 21.6~41.2%. Picoplankton was included as considerable concentration in the water of Juam lake. Therefore it is necessary to remove thoroughly the picoplankton in the water treatment processes such coagulation·sedimentation and sand filtration. The protoplasm released from destruction of picoplankton by chlorine has high possibility to cause regrowth of bacteria and pathogenic microorganism in the distribution system by playing the role of the assimilable organic carbon.

A case of acute respiratory distress syndrome treated with surfactant and low dose methylprednisolone (표면활성제와 저용량 methylprednisolone으로 치료하였던 급성 호흡 곤란 증후군 1례)

  • Choi, Bo Yeon;Kim, Kyong Mo;Yoon, Jong Seo;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.455-459
    • /
    • 2006
  • The major pathogenesis of acute respiratory distress syndrome (ARDS) is an inflammatory process that results from a diversity of injuries to the body. Due to the various cytokines and vasoactive peptides released from the endothelium, the vascular permeability is increased; the migration of inflammatory cells and the leakage of plasma proteins then occur and edema develops in the alveolus. There is a hypothesis that the impairment of alveolar recruitment in ARDS is caused by a defect of the surfactant system and the resultant increase of alveolar surface tension. This has been studied in pediatric patients in ARDS; after the administration of surfactant, hypoxia, respiratory symptoms and survival chances were improved. To alleviate the major pathogenic mechanism in this disease, that is to say, inflammation of the lung, steroids have been used and studied as another treatment modality for ARDS, and it has been concluded that the administration of low dose methylprednisolone may improve patients' symptoms and survival rates. We report here on a case of a young infant admitted with ARDS, who, after the intratracheal administration of 120 mg/kg surfactant, on $PaO_2/FiO_2$ was elevated. Subsequent low doses of methylprednisolone were given, and the symptoms did not recur, and no fibrotic change was shown during the follow-up period of 2 months.

LABORATORY STUDIES ON MIC OF AISI TYPE 304 STAINLESS STEEL USING BACTERIA ISOLATED FROM A W ASTEWATER TREATMENT SYSTEM

  • Sreekumari, Kurissery R.;Kyozo, Hirotani;Katsuya, Akamatsu;Takashi, Imamichi;Yasushi, Kikuchi
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.260-265
    • /
    • 2002
  • Microbiologically influenced Corrosion (MIC) is one of the most deleterious effects of metal microbe interactions. When a fresh metal surface comes in contact with a non-sterile fluid, biofilm formation is ensued. This might result in the initiation of corrosion. The sites and materials where MIC is implicated are versatile. Industries such as shipping, power generation, chemical etc are reported to be affected. The rapid and unexpected failure of AISI type 304 stainless steel was investigated in the laboratory by simulation studies for a period of 4 months. Slime and water samples from the failure site were screened for corrosion causing bacteria. Both aerobic and anaerobic nora were enumerated and identified using PCR techniques. Pseudomonas sp. and Bacillus sp. were the most common aerobic bacteria isolated from the water and slime samples, whilst sulfate reducing bacteria (SRB) were the major anaerobic bacteria. The aerobic bacteria were used for the corrosion experiments in the laboratory. Coupon exposure studies were conducted using a very dilute (0.1%V/V) nutrient broth medium. The coupons after retrieval were observed under a Scanning Electron Microscope (SEM) for the presence of MIC pits. Compared to sterile controls, metal coupons exposed to Pseudomonas sp and Bacillus sp. showed the initiation of severe pitting corrosion. However, amongst these two strains, Psudomonas sp. caused pits in a very short span of 14 days. Towards the end of the experiment, severe pitting was observed in both the cases. The detailed observation of pits showed they vary both in number and shapes. Whilst the coupons exposed to Bacillus sp. showed widely spread scales like pits, those exposed to Pseudomonas sp. showed smaller and circular pits, which had grown in number and size by the end of the experiment. From these results it is inferred that the rapid and unexpected failure of 304 SS might be due to MIC. Pseudonwnas sp. could be considered as the major responsible bacteria that could initiate pits in the metallic structures. As the appearance of pits was different in both the tested strains, it was thought that the mechanisms of pit formation are different. Experiments on these lines are being continued.

  • PDF

Measurement of Sputtering Yield of $RF-O_2$ Plasma treated MgO Thin Films ($RF-O_2$ Plasma 처리한 MgO 박막의 스퍼터링 수율 측정)

  • Jeong, W.H.;Jeong, K.W.;Lim, Y.C.;Oh, H.J.;Park, C.W.;Choi, E.H.;Seo, Y.H.;Kim, Y.K.;Kang, S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.259-265
    • /
    • 2006
  • We measured sputtering yield of RF $O_2-plasma$ treated MgO protective layer for AC-PDP(plasma display panel) using a Focused ion Beam System(FIB). A 10 kV acceleration voltage was applied. The sputtering yield of the untreated sample and the treated sample were 0.33 atoms/ion and 0.20 atoms/ion, respectively. The influence of the plasma-treatment of MgO thin film was characterized by XPS and AFM analysis. We observed that the binding energy of the O 1s spectra, the FWHM of O 1s spectra and the RMS(root-mean-square) of surface roughness decreased to 2.36 eV, 0.6167 eV and 0.32 nm, respectively.

Effect of Subsurface Drip Pipes Spacing on the Yield of Lettuce, Irrigation Efficiency, and Soil Chemical Properties in Greenhouse Cultivation (지중 점적관수 호스 설치 간격이 상추 수량, 관수량 및 토양 화학성에 미치는 영향)

  • Park, Jin Myeon;Lim, Tae Jun;Lee, Seong Eun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.683-689
    • /
    • 2012
  • This research was carried out to investigate the effect of installation spacing of subsurface drip irrigation pipe on the mineral content, nutrient uptake, yield of lettuce, water requirement for irrigation, and soil chemical properties in greenhouse cultivation. Semi-forcing and retarding culture were implemented in this experiment, with four treatments containing overhead spray irrigation and three subsurface irrigation lateral spacing intervals of 30, 40, 50 cm at a depth of 30 cm from soil surface, respectively. Each mineral content of lettuce grown under subirrigation system did not show significant difference between treatments, however the uptake of nutrients was lower at 50 cm-distance. The yield was largest in 30 cm-subirrigation (SI), followed by 40 cm-SI, overhead spray, and 50 cm-treatment. Water requirement for irrigation was highest in overhead spray, and it was in reverse proportion to the distance of irrigation pipes. $NO_3$-N content in the soil, at a depth of 10 cm, showed a higher value in 50 cm-SI, followed by 40 cm-SI, overhead spray and 30 cm-SI. Exchangeable K content was highest in 50 cm-SI, Mg was highest in 40 cm-SI, and Ca was lowest in 30 cm-SI. In conclusion, the lettuce yield was not different between 30 and 40 cm-SI, but water requirement for irrigation was lower as the distance of irrigation pipes was further. And it seems to be needed more precise research on this theme, because crop yield and the dynamics of soil minerals in subsurface irrigation can vary with the depth and distance of irrigation pipes, dripper, water flow depending on the soil texture, and plant response to soil minerals.

Effect of UV-LED Irradiation on Respiration and Ethylene Production of Cherry Tomatoes (방울토마토의 호흡 및 에틸렌 발생에 미치는 자외선 LED의 효과)

  • Kim, Nam-Yong;Lee, Dong-Sun;Lee, Hyuk-Jae;An, Duck-Soon
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.47-53
    • /
    • 2012
  • UV light irradiation is known to give beneficial effects on fresh produce preservation. A container system equipped with UV-LED was fabricated for storing cherry tomatoes under computer-controlled conditions of intermittent on-off cycles (1 hour on/1 hour off). Wavelength (365 and 405 nm) and physical location of the LED (2 and 5 cm above fruit) were studied as variables affecting the respiration, ethylene production and quality preservation of the fruits at 10 and $20^{\circ}C$. 365 nm wavelength gave much higher radiation intensity than 405 nm, and intensity on surface decreased in inverse proportion to square of distance from LED. When compared to non-irradiated control, UV-LED irradiation decreased the respiration by 5-10% at $10^{\circ}C$ while there was no obvious effect at $20^{\circ}C$. Ethylene production was reduced when the fruits were placed at 5 cm distance, while there was no significant difference from control at 2 cm location. The reduction of ethylene production at 5 cm was more pronounced at $20^{\circ}C$. UV-LED irradiation was shown to have delayed increase or lower concentration in carotenoids compared to control treatment. Any negative effect of UV-LED irradiation on ascorbic acid content and firmness was not observed.

Extension of Storage Time of Chicon using Nanoparticle of Machilus thunbergii Extracts (후박추출물의 나노입자화를 통한 치콘의 저장기간 연장)

  • Kwon, Min-Chul;Han, Jae-Gun;Ha, Ji-Hye;Jin, Ling;Choi, Geun-Pyo;Park, Uk-Yeon;Lee, Dal-Ho;Hyeon-Yong, Lee
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.5
    • /
    • pp.320-325
    • /
    • 2008
  • Machilus thunbergii has been showed relation to antimicrobial activity on minimal inhibitoty concentration (MIC) and colony forming inhibitory activity (CFIA) test, so that can be used to food preservatives for green vegetable. Nanoparticles has been made of edible materials. 80% of the nanoparticles has been characterized by image analyser and electron microscopy, showing in the range under 300 nm diameter. The sprayed nanoparticles remained on the surface of chicon even after washing by dilution water, then activate biological activities for storage of chicon with storing and releasement system of extracts. Chicon treated nanoparticle has been kept fresh condition about 2 months longer than 3 weeks of the non-treated control. It can be tell that treatment with nanoparticle of M. thunbergii extracts extends storage time of chicon possibly by inhibition of ethylene production through efficiency control on cell breathing.

Comparison of Chlorine, Chlorine Dioxide and Ozone as Disinfectants in Drinking Water (정수소독공정에 이용되는 염소, 이산화염소, 오존 소독제의 비교, 고찰에 관한 연구)

  • Lee, Yoon-Jin;Lee, Sun-Jong;Lee, Dong-Chan;Kim, Hyun;Lee, Hwan;Lee, Cheol-Hyo;Nam, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.1-8
    • /
    • 2002
  • The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The water sam-ples were taken from the outlet of settling basin in a conventional surface water treatment system that is provided with the raw water drawn from the mid-stream of the Han River. The inactivation of total coliform was experimentally ana-lyzed for the dose of disinfectant contact time, pH, Temperature and DOC. The nearly 2.4,3.0,3.9 log inactivation of total coliform killed by injecting 1 mか1 at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%(3 log), Disinfectants required were 1.70, 1.00 and 0.60 mか1 for chlorine, chlorine dioxide and ozone, respec-tively. The higher the pH is, the poorer the disinfections effects are in the range of pH 6-9 by using chlorine and ozone. But the irfluence of pH value on killing effects of chlorine dioxide is weak. The parameters estimated by the models of Chick-Watson, Hom, and Selleck from our experimental data obtained for chlorine are: log(N/ $N_{0}$ )=-0.16 CT with n= 1, log(N/ $N_{0}$ )=-0.71 $C^{0.87}$T with n$\neq$1, for Chicks-Watson model, log (N/ $N_{0}$ )= -1.87 $C^{0.47}$ $T^{0.36}$ for Hom model. For chlorine dioxide are: log(N/ $N_{0}$ )= -1.53 CT with n = 1, log(N/ $N_{0}$ )= -2.29 $C^{0.94}$T with n$\neq$1,, for Chicks-Watson model, log(N/ $N_{0}$ )= -3.64 $C^{0.43}$ $T^{0.24}$ for Hom model and for ozone are: log(N/ $N_{0}$ )= -2.59 CT with n = 1, log(N/ $N_{0}$ )= -2.28 $C^{0.36}$T with n$\neq$1, for Chicks-Watson model, log(N/ $N_{0}$ )= -4.53 $C^{0.26}$ $T^{0.19}$ for Hom model.19/ for Hom model.

Current Generation from Microbial Fuel Cell Using Stainless Steel Wire as Anode Electrode (스텐철사를 전극으로 이용하는 미생물연료전지의 전류 발생)

  • Jang, Jae Kyung;Kim, Kyung Min;Byun, SungAh;Ryou, Young Sun;Chang, In Seop;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.753-757
    • /
    • 2014
  • Anode electrode in a microbial fuel cell (MFC) should transfer the receiving electron as well as provide large surface area that can be immobilized microorganisms. Microorganisms' population is one of important factors to improve the current generation and to treat the livestock wastewater by biological treatment. These studies were attempted to investigate if stainless-steel wire skein (SSWS) could be used as anode electrode replacement a graphite felt electrode in microbial fuel cell. For these studies, pretreated livestock wastewater was used diluted to 500 mg/L as COD before use. At this time, the current showed a little difference of about 5% when using each of a SSW and graphite felt (control). There was no significant difference in the current value. The organic removal rate in the microbial fuel cells used graphite felt and SSWS was 82.4% and 88.3%, respectively. The COD removal in the MFC used the SSWS was higher than that of graphite felt. Ammonium nitrogen was showed similar trend in two case all. These results about current generation and organic matter reduction seem possible that SSWS was used to anode electrode. When SSWS is used, the initial investment for system construction is expected to be able to reduce by approximately 1/50.

The Effects of Warm and Cold Stimulations on the Temperature Distribution in the Prostate (냉.온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향)

  • 문우석;백병준;박복춘;김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.467-475
    • /
    • 2002
  • Hyperthermia using transrectal thermal probes has been used for a noninvasive treatment of prostate diseases. However it is known that heating the rectal wall at excessively high temperature can lead to destruction of the rectal mucous membrane. and it is difficult to maintain an optimum temperature over the entire prostate. Thus, a more accurate understanding of the heat transfer mechanism between prostate and hyperthermia system is needed Numerical analysis was performed to investigate how the cold/warm stimulations on the prostate surface affect the temperature distribution in the prostate model. The general purpose software "FLUENT" was used for obtaining a finite volume solution to the unsteady conduction equation and to calculate the time-varying temperature in the prostate. Effects of the warm/cold stimulations and the stimulation frequency on the temperature distribution were simulated. and we visualized how hyperthermia affected the inside of the prostate. It was found that the effect of hyperthermia by using a typical heating method is limited due to the low thermal conductivity of the prostate. Consecutive repetitions of warm and cold stimulations were considered to provide the thermal irritations inside a prostate. The effects of temperature difference and duration of warm/cold stimulations were investigated, and basic data for the optimum period and effective patterns of stimulations were obtained. A simplified bioheat equation was also solved to describe effects of the blood flow on the blood-tissue heat transfer. The effect of blood flow was not dominant compared to that of warm/cold stimulations. These results might be used as data for design of prostate treating probe, prostatic therapy and thermal stimulation effects on the prostate.