• 제목/요약/키워드: surface test method

검색결과 2,634건 처리시간 0.037초

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가 (Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent)

  • 조한구;한동희;이운용;임기조;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

간섭계에 있어서의 계통 오차의 자율 교정 알고리즘 (Self-calibration Algorithm of Systematic Errors For Interferometer)

  • 후지모토 이쿠마츠;이태용
    • 한국정밀공학회지
    • /
    • 제22권5호
    • /
    • pp.63-71
    • /
    • 2005
  • When an almost flat surface under test is measured by an interferometer, the measurement result is largely influenced by systematic errors that include geometrical errors of a reference flat surface. To determine the systematic errors of the interferometer by the conventional method that is called the three flat method, we must take the reference flat surface out from the interferometer and measure it. Because of difficulties to set the reference flat surface to the interferometer exactly and quickly, this method is not practical. On the other hand, the method that measures a surface under test with some shifts in the direction being perpendicular to the optical axis of the interferometer is studied. However, the parasitic pitching, rolling and up-down movement caused by the above shifts brings serious error to the measurement result, and the algorithm by which the influences can be eliminated is not still established. In this paper, we propose the self-calibration algorithm for determining the systematic errors that include geometrical errors of a reference flat surface by several rotation shifts and a linear shift of general surface under test, and verify by a numerical experiment that this algorithm is useful for determining the systematic errors.

경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구 (A Study of Standardization of Floor Slip Test method using O-Y·PSM)

  • 신윤호;강용학;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석 (An Accuracy Analysis of Run-test and RA(Reverse Arrangement)-test for Assessing Surface EMG Signal Stationarity)

  • 이진
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.291-296
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

A FINITE-ELEMENT METHOD FOR FREE-SURFACE FLOW PROBLEMS

  • Bai, Kwang-June;Kim, Jang-Whan
    • Journal of Theoretical and Applied Mechanics
    • /
    • 제1권1호
    • /
    • pp.1-27
    • /
    • 1995
  • In this paper a finite element method for free-surface problems is described. the method is based on two different forms of Hamilton's principle. To test the present computational method two specific wave problems are investigated; the dispersion relations and the nonlinear effect for the well-known solitary waves are treated. The convergence test shows that the present scheme is more efficient than other existing methods, e.g. perturbation scheme.

2-단계 기포(氣砲)의 성능 최적화에 관한 연구 (Performance Optimization of the Two-Stage Gas Gun Based on Experimental Result)

  • 이진호;배기준;전권수;변영환;이재우;허철준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.145-150
    • /
    • 2003
  • The present study aims to optimize the performance of the Two-Stage Gas Gun by using the experimentally obtained data. RSM(Response Surface Method) was adopted in the optimization process to find the operating parameter than can maximize the projectile speed with the minimum number of tests. To decide the test points which results can consist of the response surface, 3$^{k}$ full factorial method was used, and the design variables were chosen with piston mass and 2$^{nd}$ driver fill pressure. The response surface was composed by nine test results and consequently the optimization was done with GENOCOP III, inherently GA code, in order to seek the optimal test point. The optimal test condition from the response surface was verified by the experiment. Results showed that the optimization process with response surface can successfully predict the test results fairly well. This study shows the possibility of performance optimization for the experimental facilities using numerical optimization algorithm.

  • PDF

표면에너지와 거칠기가 응착력에 미치는 영향 (The Effects of Surface Energy and Roughness on Adhesion Force)

  • 나종주;권식철;정용수
    • 대한기계학회논문집A
    • /
    • 제30권11호
    • /
    • pp.1335-1347
    • /
    • 2006
  • Surface energies calculated from measured contact angles between several solutions and test samples, such as Si wafer, $Al_2O_3$, $SiO_2$, PTFE(Polytertrafluoroethylene), and DLC(Diamond Like Carbon) films, based on geometric mean method and Lewis acid base method. In order to relate roughness to adhesion force, surface roughness of test samples were scanned large area and small by AFM(Atomic Force Microscopy). Roughness was representative of test samples in large scan area and comparable with AFM tip radius in small scan area. Adhesion forces between AFM tip and test samples were matched well with order of roughness rather then surface energy. When AFM tips having different radius were used to measure adhesion force on DLCI film, sharper AFM tip was, smaller adhesion force was measured. Therefore contact area was more important factor to determine adhesion force.

Sn-Cu 무연 도금용액 및 피막의 신뢰성평가 (A Reliability Test for ph-free SnCu Plating Solution and It's Deposit)

  • 이홍기;허진영
    • 한국표면공학회지
    • /
    • 제38권6호
    • /
    • pp.216-226
    • /
    • 2005
  • Pb-Free Technology was born with environmental problems of electronic component, Being connected by big and small project of every country. Also, in each country environment is connected and various standards of IEC, ISO, MIL, JIS, KS, JEDEC, EIAJ etc. All products can divide at solder part and finishing part These can tested each and synthetically divide. This research is reliability evaluation for three kind of ph-free SnCu solder plating solution and it's deposit. First, executed analysis about Pure Sn, SnCu solutions and plating surface by way similar to other plating solution analysis. Next, executed reliability about test method and equipment for reliable analyzer system construction. Next, data comparison and estimation, main estimation test method and item's choice. In this paper the systematic surface analysis and reliability for plating solutions and it's deposit in metal surface finishing processes could be shown.

Reinforcement effect of surface stabilizer using surface curtain walls on aging reservoirs

  • Song, Sang-Huwon;Cho, Dae-Sung;Seo, Se-Gwan
    • Geomechanics and Engineering
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2022
  • In Korea, accidents related to the collapse of deteriorated aging reservoirs occur every year. The grouting method is generally applied to reinforce an aging reservoir. However, when using this method, different reinforcing effects appear depending on the ground conditions. Thus, new construction methods and materials capable of providing consistent reinforcing effects are required. In this study, the direct shear test (DST), model test, and simulation analysis were performed to evaluate the impact of surface stabilizers, generally used to reinforce roads, rivers, and slopes of roads, applied using surface curtain walls on aging reservoirs. The DST results indicate that when the surface stabilizer was mixed with in-situ soil, the increase in cohesion was the highest at a mixing ratio of 9%. No changes in the friction angle were evident; therefore, 9% was determined to be the optimal mixing ratio. In addition, the model test and simulation analysis showed that when 9% of the surface stabilizer was mixed and applied to the aging reservoir, the seepage quantity of water and the saturated area were reduced by approximately 42% and 73%, respectively. Moreover, the comprehensive analysis of results showed that the grouting method could be completely replaced by surface stabilizers applied through surface curtain walls because the technique could secure stability by decreasing the seepage in the aging reservoir.

칼날 측정법을 이용한 베어 웨이퍼 검사 방법 (Bare-ware inspection method using knife-edge optical test)

  • 이준호;김용민;김진섭;황병문
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.65-66
    • /
    • 2007
  • We present a new simple and fast bare-wafer inspection method. This method inspects the wafer front surface and inner structures simultaneously. The wafer surface is inspected using a knife-edge test in visible while the inner structure is inspected by a looking-through camera in infrared, at the same time and with a single white-light source. This paper presents a laboratory implementation of the test method with some experimental results.

  • PDF