• Title/Summary/Keyword: surface reinforcement

Search Result 686, Processing Time 0.026 seconds

3D Shape Embodiment of Dam using the 3D Laser Scanning System (3차원 레이저 스케닝 시스템을 이용한 댐체의 3차원 형상구현)

  • Shon, Ho-Woong;Yun, Bu-yeol;Park, Dong-il;Pyo, Ki-Won
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.4
    • /
    • pp.377-386
    • /
    • 2006
  • There is an inseparable relation between human race and engineering work. As world developed into highly industrialized society, a diversity of large structures is being built up correspondently to limited topographical circumstance. Though large structures are national establishments which provide us with convenience of life, there are some disastrous possibilities which were never predicted such as ground subsidence and degradation. It is very difficult to analyze the volume of total metamorphosis with the relative displacement measurement system which is now used and it is impossible to know whether there is structural metamorphosis within a permissible range of design or not. In this research with an object of 13-year-old earthen dam, through generating point-cloud which has 3D spatial coordinates(x, y, z) of this dam by means of 3D Laser Scanning, we can get real configuration data of slanting surface of this dam with this method of getting a number of 3D spatial coordinates(x, y, z). It gives 3D spatial model to us and we can get various information of this dam such as the distance of slanting surface of dam, dimensions and cubic volume. It can be made full use of as important source material of reinforcement and maintenance works to detect previously the bulging of the dam through this research.

  • PDF

The Analysis of Effect of Biopolymer Treated Soils in Seed Spray Method in the River Embankment (제방 녹화공법에서 바이오폴리머 처리토의 효능 분석)

  • Seo, Seunghwan;Jin, Seungnam;Chang, Ilhan;Chung, Moonkyung
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.4
    • /
    • pp.304-313
    • /
    • 2019
  • Biopolymer based on microbial β-glucan and xanthan gum is effective for vegetation and has a function of enhancing soil strength, which can be used as soil reinforcement and stabilization materials in river embankment. The purpose of this study is to verify the vegetation effect of the surface of levee by biopolymer with seed spraying method. Mixed soils with biopolymer were used to cover the surface of embankments. The strength is higher in biopolymer-treated soil and xanthan gum based biopolymer has advantage for quality control in field scale. In addition, the vegetation of F. arundinacea and L. perenne showed various reactions with types of biopolymers. Biopolymer has a positive effect on the vegetation of them. In contrast, root growth tended to decrease in biopolymer-treated soils. The results indicate that root growth is slow down due to increasing ability to retain water in biopolymer-treated soil. In order to apply biopolymer to river embankment, it is necessary to examine the effects of biopolymers on a wide range of plant species in river embankment.

Deterioration Evaluation and Material Characteristics of the Usuki Stone Buddha Statues in Oita, Japan (일본 오이타현 우스키 마애불상군의 재질특성 및 손상도 평가)

  • Cho, Ji-Hyun;Lee, Chan-Hee;Kim, Ji-Young;Morii, Masayuki;Lee, Myeong-Seong;Kim, Sa-Dug
    • Journal of Conservation Science
    • /
    • v.28 no.1
    • /
    • pp.39-52
    • /
    • 2012
  • The Usuki Stone Buddha Statues in Oita are consisted of 60 Buddhas which represent of Japan carved on the rock-cliff in the 12 to 14th centuries. The basement rock of the statues is dark gray welded lapilli tuff that containing the Aso-4 pyroclastic rock group. Deterioration maps for the Hoki I and the Furuzono Buddha Statues group show multi-directional fissures on the Cakra, and sheeting-off zone at the margin of uprising water. Deterioration rate of the Hoki I group was calculated fissure about 121 in number, 19% of sheeting-off zone and 51% of biological weathering in surface of area. And the Furuzono group was also evaluated as about 48 of fissures in number, 24% of sheeting-off zone and 41% biological weathering. The slope stability assessment results, the Hoki I developed discontinuous planes has possibility of planar, toppling and wedge failures in all caves. Ultrasonic velocity of the Aizen-myooh (basement rock) ranges from 1,520 to 2,794 (average 2,298m/s). And pedestal of Amita-yeorae which has been replaced by new fresh rock is measured as 3,242 to 4,141 (average 3,813m/s). Therefore, we establish of planing conservation treatment and reinforcement methods to fissure, cavity, sheeting-off zone in the Buddha surface.

Verification of Reinforcement with Grouting Materials in a Small Scale Reservoir Dike using Surface and Borehole Electrical Resistivity survey (지표 및 시추공 전기비저항 탐사를 중심으로)

  • Song, Sung-Ho;Yong, Hwan-Ho;Kim, Yang-Bin
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.239-245
    • /
    • 2009
  • To verify the reinforcing effect of grouting materials composed of colloid cement and ordinary portland cement on the water leakage region in a small scale dike, we performed a tubecasing method and applied surface electrical resistivity survey including electrical resistivity tomography (ERT) to find resistivity variation before and after grouting. Hydraulic conductivities after grouting show 10 times lower than those of before grouting. These variation indicates that the cement grout blocks the leakage pathway effectively. As the results of dipole-dipole resistivity survey along the dike, resistivity distribution after grouting did not represent noticeable spatial variation in time. Resistivity monitoring results at the dike with vertical electrical sounding (VES) showed that the region of decreasing apparent resistivity was occupied by the grout after grouting. Predicted resistivities from the inversion of ERT data well matched with results of VES at the same regions. From the ERT using check holes to inspect the effect of grouting, we could find that the ERT is quite effective to identify spatially the grout region in a dike.

Analysis of Tack Properties of Aramid/Phenolic Prepreg (아라미드섬유/페놀수지 프리프레그의 Tack성 분석)

  • Hong, Tae Min;Lee, Ji Eun;Hong, Young Ki;Lee, Jung Soon;Cho, Dae Hyun;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.14 no.3
    • /
    • pp.117-120
    • /
    • 2013
  • The prepreg material is a sheet of the reinforcement pre-impregnated with a resin. In this study, two types of prepreg were prepared with a general phenolic resin and the polyvinyl butyral (PVB) modified phenolic resin, respectively, with resin content of 40 wt%. After resin impregnation, the prepregs were heat treated in an oven to make them the B-stage. Surface morphology of the prepreg was observed by using a scanning electron microscope (SEM). Tack property of the prepreg is one of the major properties that govern the ability of prepreg to be laid up. In this study, the tack of prepreg was measured under various test parameters by a probe tact test. Test parameters were contact time, contact force and debonding rate. Most of the tack properties of the prepreg increased with the test parameters. Then tack properties exhibited a linear behavior with test parameters before a saturation point. Also, the tack of prepreg was investigated in relation with the fibrillation phenomena involved in the prepreg surface with the debonding rate.

Analysis of Surface Contaminants and Physical Properties of the Daejanggakgibi Stele of Silleuksa Temple using Non-destructive Technology (비파괴 기술을 활용한 여주 신륵사 대장각기비의 표면오염물 분석과 물성진단)

  • KIM, Jiyoung;LEE, Myeongseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.2
    • /
    • pp.186-197
    • /
    • 2022
  • The Daejanggakgibi Stele of Silleuksa Temple in Yeoju is a stone stele from the Goryeo Dynasty that is inscribed with various stories about the construction of Daejanggak, a place where Buddhist scriptures were kept. This stele has been maintained for a long time in a state in which discoloration of the body has occurred, and the inscription has been partially damaged due to dozens of cracks. Using non-destructive analysis methods for stone artifacts, material investigation, portable X-ray fluorescence analysis, and ultrasonic velocity analysis for the stele were performed. It was confirmed that the stele body was composed of light gray crystalline limestone, and the base stone, support stone, and cover stone were medium-grained biotite granite. Portable X-ray fluorescence analysis confirmed that iron(Fe) was an original coloring element of the stele surface. From the distribution pattern of the coloration, it can be inferred that iron-containing materials flew down from between the stele body and the cover stone. Thereafter, living organisms or organic contaminants attached to it so that yellow and black contaminants were formed. Ultrasonic diagnosis revealed that the physical property of both the front and back surfaces ranged from fresh rocks(FR) to completely weathered rocks(CW), and the average weathering index was grade 3(intermediate). However, the point where cracks developed intensively was judged to be the completely weathered stage(CW), and some cracks located in the upper and lower parts of the stele bear potentially very high risk. It is necessary to monitor the movement of these cracks and establish reinforcement measures for conservation in the future.

A Study on the Error Rate of Non-destructive Rebar Detection Under Different Environmental Factors (환경적 요인에 따른 비파괴 철근 탐사의 오차율에 관한 연구)

  • Kang, Beom-Ju;Kim, Young-Hwan;Kim, Young-Min;Park, Kyung-Han;Oh, Hong-Seob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.506-513
    • /
    • 2021
  • The durability and safety of reinforced concrete structures significantly depend on the reinforcement conditions, concrete cover thickness, cracks, and concrete strength. There are two ways to accurately determine the information on reinforcing bars embedded in concrete - the local destructive method and the non-destructive rebar detection test. In general, the non-destructive rebar detection tests, such as the electromagnetic wave radar method, electromagnetic induction method, and radiation method, are adopted to avoid damage to the structural elements. The moisture content and temperature of concrete affect the dielectric constant, which is the electrical property of concrete, and cause interference in the non-destructive rebar detection test results. Therefore, in this study, the effects of the electromagnetic wave radar method and electromagnetic induction method have been analyzed according to the temperature and surface moisture content of concrete. Due to the technological advancement and development of equipment, the average error rate was less than 5% in the specimens at 24℃, irrespective of their operating principles. Among the tested methods, the electromagnetic induction method showed very high accuracy. The electromagnetic wave radar method indicated a relatively small error rate in the dry state than in the wet state, and exhibited a relatively high error rate at high temperatures. It was confirmed that the error could be reduced by applying the electromagnetic wave radar method when the temperature of the probe was low and in a dry state, and by using the electromagnetic induction method when the probe was in a wet state or at a high temperature.

Characteristics of Collapsed Retaining Walls Using Elasto-plastic Method and Finite Element Method (탄소성 방법과 유한요소법에 의한 붕괴 토류벽의 거동차이 분석)

  • Jeong, Sang-Seom;Kim, Young-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.19-29
    • /
    • 2009
  • In this study, a numerical analysis was performed to predict the sequential behavior of anchored retaining wall where the failure accident took place, and verified accuracy of prediction through the comparisons between prediction and field measurement. The emphasis was given to the wall behaviors and the variation of sliding surface based on the two different methods of elasto-plastic and finite element (shear strength reduction technique). Through the comparison study, it is shown that the bending moment and the soil pressure at construction stages produce quite similar results in both the elasto-plastic and finite element method. However, predicted wall deflections using elasto-plastic method show underestimate results compared with measured deflections. This demonstrates that the elasto-plastic method does not clearly consider the influence of soil-wall-reinforcement interaction, so that the tension force (anchor force and earth pressure) on the wall is overestimated. Based on the results obtained, it is found that finite element method using shear strength reduction method can be effectively used to perform the back calculation analysis in the anchored retaining wall, whereas elasto-plastic method can be applicable to the preliminary design of retaining wall with suitable safety factor.

Field Applicability Evaluation Experiment for Ultra-high Strength (130MPa) Concrete (초고강도(130MPa) 콘크리트의 현장적용성 평가에 관한 실험)

  • Choonhwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.20-31
    • /
    • 2024
  • Purpose: Research and development of high-strength concrete enables high-rise buildings and reduces the self-weight of the structure by reducing the cross-section, thereby reducing the thickness of beams and slabs to build more floors. A large effective space can be secured and the amount of reinforcement and concrete used to designate the base surface can be reduced. Method: In terms of field construction and quality, the effect of reducing the occurrence of drying shrinkage can be confirmed by studying the combination of low water bonding ratio and minimizing bleeding on the concrete surface. Result: The ease of site construction was confirmed due to the high self-charging property due to the increased fluidity by using high-performance water reducing agents, and the advantage of shortening the time to remove the formwork by expressing the early strength of concrete was confirmed. These experimental results show that the field application of ultra-high-strength concrete with a design standard strength of 100 MPa or higher can be expanded in high-rise buildings. Through this study, we experimented and evaluated whether ultra-high-strength concrete with a strength of 130 MPa or higher, considering the applicability of high-rise buildings with more than 120 floors in Korea, could be applied in the field. Conclusion: This study found the optimal mixing ratio studied by various methods of indoor basic experiments to confirm the applicability of ultra-high strength, produced 130MPa ultra-high strength concrete at a ready-mixed concrete factory similar to the real size, and tested the applicability of concrete to the fluidity and strength expression and hydration heat.

Precise Diagnosis and Conservation Treatment of the Twin-lion Stone Lantern from the Godalsa Temple Site, Yeoju (여주 고달사지 쌍사자 석등의 정밀진단 및 보존처리)

  • National Museum of Korea Conservation Science Division;Damwon Cultural Heritage Inc.;Man Gyeong Corp.
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.71-103
    • /
    • 2024
  • The National Museum of Korea Conservation science division conducted a precise diagnosis and a non-destructive investigation to comprehensively assess the overall damage of the Twin-lion stone lantern from the Godalsa Temple site, Yeoju to be placed on display in the museum's outdoor stone garden, then reviewed the relevant conservation and management plan and applied conservation treatment to the artifact. The museum carried out the treatment in the following order: precise diagnosis; dismantling of the previously-restored part of the roof stone; reinforcement and restoration of the roof structure with new stone; restoration of the previously-restored part of the lantern's support stone (jungseok); surface texture treatment to the restored area; cleaning (basic, laser); and color matching. The previously-restored part of the roof stone was removed and restored with new stone material, based on the results of a safety diagnosis regarding the separation at the said part. Granite from the Sangju area was selected as the material for the restoration in consideration of the results of mineral analysis as well as the surface color and particle size. The new stone was divided into three pieces based on the descending edges of the octagonal roof structure and joined together using epoxy resin. The structure was further strengthened by inserting titanium rods. It is expected that the status diagnosis and conservation treatment of the twin-lion stone lantern from the Godalsa Temple site in Yeoju will be used as a reference for the future conservation and management of outdoor displays of stone cultural heritage.