• Title/Summary/Keyword: surface radiation

Search Result 2,134, Processing Time 0.036 seconds

The Usability Test of Manufactured Rounded Extension in Proton Therapy (자체 제작한 양성자 치료용 Rounded Extension의 유용성 평가)

  • Park, Ji-Yeon;Jang, Yo-Jong;Kang, Dong-Yun;Yeom, Du-Seok;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose: Long Extension (LE) is used in proton therapy for lung and abdomen. However, it has limitations in surface area, produces collision in posterior oblique beam which creates limitations in various gantry angles in planning therapy and increases air gap (distance between patient and compensator). Therefore, this study investigates the usability of manufactured Rounded Extension (RE) in comparison to LE to use the most suitable extension in proton therapy. Materials and Methods: To compare structural features of LE and RE. This study investigated usable gantry angle for snout sizes 100, 180 and 250 and CT scanned Humanoid phantom. And it compared the air gap in posterior oblique direction. Results: The structural features of two extensions are as follow. Because of the existence of supporting bar, the width of LE was 40 cm and RE was 50 cm. Result of the investigation of usable gantry angle for snout sizes 100, 180 and 250 are as follow. LE is ${\pm}36$ (average) at 180 degree and RE is ${\pm}70$ (average). And also, the air gap of RE is decreased by 11.3 cm in average at the same gantry angle. Conclusion: Manufactured RE for proton therapy has several benefits than LE. Its therapy surface area is wider and range of usable gantry angle is also wider. Also, the air gap at the posterior oblique beam has decreased. Therefore the usability of RE in proton therapy of lung and abdomen will be increased compared to LE. However, the air gap of proton therapy at the lateral direction may be increased, so there may be need for make up to decrease air gap at the lateral direction in the future.

  • PDF

Sensitivity of Aerosol Optical Parameters on the Atmospheric Radiative Heating Rate (에어로졸 광학변수가 대기복사가열률 산정에 미치는 민감도 분석)

  • Kim, Sang-Woo;Choi, In-Jin;Yoon, Soon-Chang;Kim, Yumi
    • Atmosphere
    • /
    • v.23 no.1
    • /
    • pp.85-92
    • /
    • 2013
  • We estimate atmospheric radiative heating effect of aerosols, based on AErosol RObotic NETwork (AERONET) and lidar observations and radiative transfer calculations. The column radiation model (CRM) is modified to ingest the AERONET measured variables (aerosol optical depth, single scattering albedo, and asymmetric parameter) and subsequently calculate the optical parameters at the 19 bands from the data obtained at four wavelengths. The aerosol radiative forcing at the surface and the top of the atmosphere, and atmospheric absorption on pollution (April 15, 2001) and dust (April 17~18, 2001) days are 3~4 times greater than those on clear-sky days (April 14 and 16, 2001). The atmospheric radiative heating rate (${\Delta}H$) and heating rate by aerosols (${\Delta}H_{aerosol}$) are estimated to be about $3\;K\;day^{-1}$ and $1{\sim}3\;K\;day^{-1}$ for pollution and dust aerosol layers. The sensitivity test showed that a 10% uncertainty in the single scattering albedo results in 30% uncertainties in aerosol radiative forcing at the surface and at the top of the atmosphere and 60% uncertainties in atmospheric forcing, thereby translated to about 35% uncertainties in ${\Delta}H$. This result suggests that atmospheric radiative heating is largely determined by the amount of light-absorbing aerosols.

Effects of 166Holmium and 166Holmium-chitosan Complex(166Ho-CHICO) on Normal Brain of Rats (홀뮴 및 홀뮴-키토산 복합체가 정상 백서 뇌에 미치는 효과에 대한 연구)

  • Sun, Jing He;Joh, Chul W;Ahn, Young Hwan;Park, Chan Hee;Shim, Chull;Park, Kyung Bae;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1309-1315
    • /
    • 2000
  • Objectives : We performed an in vivo experiment to investigate the effect of $^{166}Holmium$ and $^{166}Holmium$-chitosan complex($^{166}Ho$-CHICO) on the normal brain of rats and to determine the sublethal dose of $^{166}Ho$-CHICO. Materials and Methods : $^{166}Ho$ is a beta and gamma ray emitter. $^{166}Ho$-CHICO is a novel radio-pharmaceutical complex with chitosan to facilitate the transport of $^{166}Ho$ obtained from Korea Atomic Energy Research Center(Taejon, Korea). It is in acidic form and becomes gel state at alkaline pH. One hundred and seventy consecutive rats were divided into four groups : $^{166}Ho$ treated(n=50), $^{166}Ho$-CHICO treated(n=57), saline treated(n=5) and chitosan treated(n=5) groups. $^{166}Ho$ and $^{166}Ho$-CHICO were injected into the rat brain stereotactically with various doses of 0.1mCi/$20{\mu}l$, 0.2mCi/$20{\mu}l$, 0.3mCi/$20{\mu}l$, and 0.4mCi/$20{\mu}l$ using an automated microinjector. Nuclear imaging, histopathological and hematological studies were performed in 10 rats in each group at 1 day, 3days, 7 days, 1 month and 3 months after the injections. Results : An infiltration of inflammatory cells and necrotic changes were noted in $^{166}Ho$ treated group at 1 week after the injection. A wedge-shaped tissue defect due to necrosis, lined with infiltrated glial cells in $^{166}Ho$ treated group and a cystic defect lined with reactive astroglial cells in $^{166}Holmium$-CHICO treated group at 3 months after the injection were observed. $^{166}Ho$ alone without chitosan leaked out and caused necrotic lesion on the cerebral surface but $^{166}Holmium$-CHICO treated group did not show this feature. As the dose of $^{166}Ho$ increased, the mortality rates were also increased. The mortality rate of the $^{166}Holmium$-CHICO group was higher than the $^{166}Ho$ treated group at a dose of 0.4mCi/$20{\mu}l$/300g. There was no detectable radioactivity due to the leakage or extravasation from the injected site of the brain on the scintigraphy performed at 1 hour, 24 hours and 48 hours after the injection. There was also no detectable activity of $^{166}Holmium$-CHICO in other organs including spleen, liver and kidney. Conclusions : $^{166}Ho$-CHICO did not leak out to the critical cortical surface of the brain from the injection site and induced radiation changes of the parenchyma around the injection site without cortical damage. The sublethal dose of $^{166}Ho$-CHICO for the normal brain in rats was determined to be 0.2mCi/$20{\mu}l$/300g.

  • PDF

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields (Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.337-345
    • /
    • 1998
  • Purpose : To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated Materials and Method : The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of target-skin distance (TSD) and full collimator size (35*35 $cm^2$ on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cm * 105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. Results : The full width at half maximum(FWHM) of dose profile was 130 cm in large field of 105*105 $cm^2$ The width of $100\pm10\%$ of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose unifomity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80$\%$ depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. Conclusion : The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within$\pm10\%$ difference except the protruding area of skin which needs a shield and deeply curvatured region of skin which needs boosting dose.

  • PDF

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Study on the Effectiveness of some Decontamination Agents against Skin Contamination of $^{137}Cs$ and $^{60}Co$ (제염제의 $^{137}Cs$$^{60}Co$에 의한 피부오염의 제염효과에 관한 연구)

  • Chon, Je-Keun;Ji, Pyung-Kook;Kwak, Sang-Soo;Kim, Byung-Tae;Park, Chong-Mook
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 1998
  • In order to evaluate the effectiveness of some decontamination agents against skin contamination of $^{60}Co$ and $^{137}Cs$, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin , $^{60}CoC1_2$ and $^{137}CsCl$ were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, KAERICON which was developed for decontamination of radionulides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-tay detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of $^{137}Cs$ and $^{60}Co$, respectively, were panerated into the skin. In the experiment to remove the residual radioactivity fixed on the skin, KAERICON showed the decontamination rates up to 52.1%(decontamination factor of 2.1) and IOCON showed the equivalent decontamination rate (decontamination factor 1.9) for $^{137}Cs$. However, IOCON and CHARCON showed the poor decontamination rates of less than 20%(decontamination factor of 1.2) for $^{60}Co$, and KAERICON showed the poor decontamination rate (decontamination factor 1.1) for $^{60}Co$. For TRICON, the decontamination factors were 1.6 to 1.8 for $^{137}Cs$, and 1.0 to 1.2 for $^{60}Co$, respectively.

  • PDF

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

On Using Near-surface Remote Sensing Observation for Evaluation Gross Primary Productivity and Net Ecosystem CO2 Partitioning (근거리 원격탐사 기법을 이용한 총일차생산량 추정 및 순생태계 CO2 교환량 배분의 정확도 평가에 관하여)

  • Park, Juhan;Kang, Minseok;Cho, Sungsik;Sohn, Seungwon;Kim, Jongho;Kim, Su-Jin;Lim, Jong-Hwan;Kang, Mingu;Shim, Kyo-Moon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.251-267
    • /
    • 2021
  • Remotely sensed vegetation indices (VIs) are empirically related with gross primary productivity (GPP) in various spatio-temporal scales. The uncertainties in GPP-VI relationship increase with temporal resolution. Uncertainty also exists in the eddy covariance (EC)-based estimation of GPP, arising from the partitioning of the measured net ecosystem CO2 exchange (NEE) into GPP and ecosystem respiration (RE). For two forests and two agricultural sites, we correlated the EC-derived GPP in various time scales with three different near-surface remotely sensed VIs: (1) normalized difference vegetation index (NDVI), (2) enhanced vegetation index (EVI), and (3) near infrared reflectance from vegetation (NIRv) along with NIRvP (i.e., NIRv multiplied by photosynthetically active radiation, PAR). Among the compared VIs, NIRvP showed highest correlation with half-hourly and monthly GPP at all sites. The NIRvP was used to test the reliability of GPP derived by two different NEE partitioning methods: (1) original KoFlux methods (GPPOri) and (2) machine-learning based method (GPPANN). GPPANN showed higher correlation with NIRvP at half-hourly time scale, but there was no difference at daily time scale. The NIRvP-GPP correlation was lower under clear sky conditions due to co-limitation of GPP by other environmental conditions such as air temperature, vapor pressure deficit and soil moisture. However, under cloudy conditions when photosynthesis is mainly limited by radiation, the use of NIRvP was more promising to test the credibility of NEE partitioning methods. Despite the necessity of further analyses, the results suggest that NIRvP can be used as the proxy of GPP at high temporal-scale. However, for the VIs-based GPP estimation with high temporal resolution to be meaningful, complex systems-based analysis methods (related to systems thinking and self-organization that goes beyond the empirical VIs-GPP relationship) should be developed.

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.