• Title/Summary/Keyword: surface radiation

Search Result 2,139, Processing Time 0.033 seconds

Gamma irradiation and subsequent storage reduce patulin content in apple juice

  • Hyejeong Yun;Dong-Ho Kim;Jung-Ok Kim;Gee-Dong Lee;Joong-Ho Kwon
    • Food Science and Preservation
    • /
    • v.31 no.3
    • /
    • pp.499-505
    • /
    • 2024
  • Patulin has been reported as a risk factor in various foods, especially apple juice. This study monitored residual patulin and polyphenolic content in apple juice during post-irradiation storage conditions. Response surface methodology (RSM) was applied to monitor the changes in dependent variables (Yn, patulin, and polyphenolics) as affected by independent variables, such as storage temperature (Xi, -20℃ to 20℃), irradiation dose (Xii, 0-2 kGy), and storage period (Xiii, 0-20 days), which were based on a central composite design. The predicted peak point resulted in the lowest residual patulin content of 58.42 ppb with the corresponding independent parameter conditions, such as 18.19℃ of storage temperature, 1.24 kGy of irradiation dose, and 13.42 days of storage period. The residual patulin content of 58.42 ppb is the minimum desirable level, representing a 91% reduction compared to the non-irradiated control (675.00 ppb). A maximum polyphenolics content (11.98 mg/g) was obtained under the predicted maximum conditions of 14.40℃, 0.78 kGy, and 3.4 days. The most influential parameter in reducing residual patulin content while maintaining polyphenolic content in apple juice was irradiation dose (p<0.01), which showed potential to be applied in controlling the patulin levels in apple juice.

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.

Recent Variations of UV Irradiance at Seoul 2004~2010 (서울의 최근 자외선 복사의 변화 2004~2010)

  • Kim, Jhoon;Park, Sang Seo;Cho, Nayeong;Kim, Woogyung;Cho, Hi Ku
    • Atmosphere
    • /
    • v.21 no.4
    • /
    • pp.429-438
    • /
    • 2011
  • The climatology of surface UV radiation for Seoul, presented in Cho et al. (1998; 2001), has been updated using measurement of surface erythemal ultraviolet (EUV) and total ultraviolet (TUV) irradiance (wavelength 286.5~363.0 nm) by a Brewer Spectrophotometer (MK-IV) for the period 2004~2010. The analysis was also carried out together with the broadband total (global) solar irradiance (TR ; 305~2800 nm) and cloud amount to compare with the UV variations, measured by Seoul meteorological station of Korean Meteorological Agency located near the present study site. Under all-sky conditions, the day-to-day variability of EUV exhibits annual mean of 98% in increase and 31% in decrease. It has been also shown that the EUV variability is 17 times as high as the total ozone in positive change, whereas this is 6 times higher in negative change. Thus, the day to day variability is dominantly caused rather by the daily synoptic situations than by the ozone variability. Annual mean value of daily EUV and TUV shows $1.62kJm^{-2}$ and $0.63MJm^{-2}$ respectively, whereas mean value of TR is $12.4MJm^{-2}$ ($143.1Wm^{-2}$). The yearly maximum in noon-time UV Index (UVI) varies between 9 and 11 depending on time of year. The highest UVI shows 11 on 20 July, 2008 during the period 2004~2010, but for the period 1994~2000, the index of 12 was recorded on 13 July, 1994 (Cho et al., 2001). A 40% of daily maximum UVI belongs to "low (UVI < 2)", whereas the UVI less than 5% of the maximum show "very high (8 < UVI < 10)". On average, the maximum UVI exceeded 8 on 9 days per year. The values of Tropospheric Emission Monitoring Internet Service (TEMIS) EUV and UVI under cloud-free conditions are 1.8 times and 1.5 times, respectively, higher than the all-sky measurements by the Brewer. The trend analysis in fractional deviation of monthly UV from the reference value shows a decrease of -0.83% and -0.90% $decade^{-1}$ in the EUV and TUV, respectively, whereas the TR trend is near zero (+0.11% $decade^{-1}$). The trend is statistically significant except for TR trend (p = 0.279). It is possible that the recent UV decrease is mainly associated with increase in total ozone, but the trend in TR can be attributed to the other parameters such as clouds except the ozone. Certainly, the cloud effects suggest that the reason for the differences between UV and TR trends can be explained. In order to estimate cloud effects, the EUV, TUV and TR irradiances have been also evaluated for clear skies (cloud cover < 25%) and cloudy skies (cloud cover ${\geq}$ 75%). Annual mean values show that EUV, TUV and TR are $2.15kJm^{-2}$, $0.83MJm^{-2}$, and $17.9MJm^{-2}$ for clear skies, and $1.24kJm^{-2}$, $0.46MJm^{-2}$, and $7.2MJm^{-2}$ for cloudy skies, respectively. As results, the transmission of radiation through clouds under cloudy-sky conditions is observed to be 58%, 55% and 40% for EUV, TUV and TR, respectively. Consequently, it is clear that the cloud effects on EUV and TUV are 18% and 15%, respectively lower than the effects on TR under cloudy-sky conditions. Clouds under all-sky conditions (average of cloud cover is 5 tenths) reduced the EUV and TUV to about 25% of the clear-sky (cloud cover < 25%) values, whereas for TR, this was 31%. As a result, it is noted that the UV radiation is attenuated less than TR by clouds under all weather conditions.

Effects of X-ray Irradiation on the Survival Rate and Weight of the Rhinoceros Beetle Larvae (X선 이 장수풍뎅이 유충의 체중과 생존율에 미치는 영향)

  • Lee, Won-Jeong;Lim, Dong-Hwan;Park, Jeong-Soon;Sim, Yeung-Eun;Jeong, Yoo-Jin;Kim, Jeong Ho;Yoo, Se Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.271-277
    • /
    • 2020
  • The Purpose of this study was to examine the survival rate and weight of rhinoceros beetle larvae by irradiating X-rays which are most commonly used in diagnosing and treating for diseases. Subjectts and Methods: In early April 2019, the rhinoceros beetle larvae 41 were classified into two groups as control group (11 larvae) and irradiated group (10 Gy, 20 Gy, 30 Gy, each 10 larvae). The irradiated group was exposed by 6 MV X-ray using linear accelerators (Clinac IS, VERIAN, USA) at the University Hospital in Daejeon (Source-surface distance 96 cm, field size 18 × 10 cm, dose rate 600 MU/min), after environmental adaptation for 3 days (temperature 20.6℃, humidity 64.3%). The survival rate and weight were measured weekly after irradiating X-ray. All statistical analyses were performed using the SPSS ver. 22.0 (Chicago, IL, USA). The weight was analysed by Independent T-test, by cross-sectional analysis for survival rates between control and X-ray irradiated groups. Also, the correlation between dose and weight was analyzed by Spearman test. In 3-week after irradiating X-ray, weight was significant difference between control group and irradiated group (10 Gy or 20 Gy, p < 0.05; and 30 Gy, p < 0.01) with increasing weight in all experimental groups. In 14-week, weight was increased in the control group, but decreased in irradiated group. weight was significant difference between control group and irradiated group. The survival rate in 3-week was decreased rapidly in all experimental group except 10 Gy, to 4-week in irradiated group. The control group had no change in survival rate 54.5% from 3-week to 14-week. From the 3-week, it showed lower survival rate with increasing radiation dose in irradiated group. In 19-week, survival rate of control group and 10 Gy was 45.4% and 30.0% respectively, all died in 20 Gy and 30 Gy. Weight was significantly negative correlated with radiation dose as longer time after irradiating X-ray. The weight and survival rate of rhino beetle larvae is affected by irradiating X-rays, weight and survival rate decreased more in higher dose.

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Dose Alterations at the Distal Surface by Tissue Inhomogeneity in High Energy Photon Beam (조직 불균질성에 의한 고에너지 광자선의 선량변화)

  • Kim, Young-Ai;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.277-283
    • /
    • 1995
  • Purpose : This study was performed to measure dose alteration at the air-tissue interface resulting from rebuild-up to the loss of charged particle equilibrium in the tissues around the air-tissue interfaces. Materials and Methods : The 6 and 10-MV photon beam in dual energy linear accelerator were used to measure the surface dose at the air-tissue interface The polystyrene phantom sized $25{\times}25{\times}5\;cm^3$ and a water phantom sized $29{\times}29{\times}48\;cm^3$ which incorporates a parallel-plate ionization chamber in the distal side of air gap were used in this study. The treatment field sizes were $5{\times}5\;cm^2,\;10{\times}10\;cm^2\;and\;20{\times}20\;cm^2$. Air cavity thickness was variable from 10 mm to 50 mm. The observed-expected ratio (OER) was defined as the ratio of dose measured at the distal junction that is air-tissue interface to the dose measured at the same point in a homogeneous phantom. Results : In this experiment, the result of OER was close or slightly over than 1.0 for the large field size but much less (about 0.565) than 1.0 for the small field size in both photon energy. The factors to affect the dose distribution at the air-tissue interface were the field size, the thickness of air cavity. and the photon energy. Conclusion : Thus, the radiation oncologist should take into account dose reduction at the air-tissue interface when planning the head and neck cancer especially pharynx and laryngeal lesions, because the dose can be less nearly $29{\%}$ than predicted value.

  • PDF

Calculation of Surface Broadband Emissivity by Multiple Linear Regression Model (다중선형회귀모형에 의한 지표면 광대역 방출율 산출)

  • Jo, Eun-Su;Lee, Kyu-Tae;Jung, Hyun-Seok;Kim, Bu-Yo;Zo, Il-Sung
    • Journal of the Korean earth science society
    • /
    • v.38 no.4
    • /
    • pp.269-282
    • /
    • 2017
  • In this study, the surface broadband emissivity ($3.0-14.0{\mu}m$) was calculated using the multiple linear regression model with narrow bands (channels 29, 30, and 31) emissivity data of the Moderate Resolution Imaging Spectroradiometer (MODIS) on Earth Observing System Terra satellite. The 307 types of spectral emissivity data (123 soil types, 32 vegetation types, 19 types of water bodies, 43 manmade materials, and 90 rock) with MODIS University of California Santa Barbara emissivity library and Advanced Spaceborne Thermal Emission & Reflection Radiometer spectral library were used as the spectral emissivity data for the derivation and verification of the multiple linear regression model. The derived determination coefficient ($R^2$) of multiple linear regression model had a high value of 0.95 (p<0.001) and the root mean square error between these model calculated and theoretical broadband emissivities was 0.0070. The surface broadband emissivity from our multiple linear regression model was comparable with that by Wang et al. (2005). The root mean square error between surface broadband emissivities calculated by models in this study and by Wang et al. (2005) during January was 0.0054 in Asia, Africa, and Oceania regions. The minimum and maximum differences of surface broadband emissivities between two model results were 0.0027 and 0.0067 respectively. The similar statistical results were also derived for August. The surface broadband emissivities by our multiple linear regression model could thus be acceptable. However, the various regression models according to different land covers need be applied for the more accurate calculation of the surface broadband emissivities.

A Study of Cleaning Technology for Zirconium Scrap Recycling in the Nuclear Industry (원자력산업에서 지르코늄 스크랩 재활용을 위한 세정기술에 관한 연구)

  • Lee, Ji-Eun;Cho, Nam-Chan;An, Chang-Mo;Noh, Jae-Soo;Moon, Jong-Han
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.264-271
    • /
    • 2013
  • In this study, we optimized the removal condition of contaminants attached on the scrap surface to recycle the scrap generated from the Zr alloy tube manufacturing process back to the nuclear grade. The main contaminant is remnant of watersoluble cooling lubricant that is used in the pilgering manufacture during the tube production, and it is assumed to be compressed and carbonized on the surface of tube. Zirlo alloy tube of ${\phi}9.50mm$, which has high occurrence frequency of scrap, was selected as the object to be cleaned, and cleaning abilities of reagents were evaluated by measuring the characteristics of contaminants remained and by analyzing the surface of the tube after cleaning process. For evaluation of each cleaning agent, we selected two types of sodium hydroxide series and three types of potassium hydroxide series. Furthermore, to confirm dependence on tempe-rature and ultrasonic intensities, cleaning at the room temperature, $40^{\circ}C$, and $60^{\circ}C$ was conducted, and results showed that higher the cleaning temperature and higher the ultrasonic intensity, better the cleaning effect. As a result of the bare-eye inspection, while the use of sodium hydroxide provided satisfactory condition on the tube surface, the use of potassium hydroxide series provided satisfactory condition on the tube surface only when the ultrasonic intensity was over 120 W. In the cleaning effect analysis using the gravimetric method, cleaning efficiency of sodium hydroxide series was as high as 97.6% ($60^{\circ}C$, 120 W), but since the tube surface condition was poor after the use of potassium hydroxide, the gravimetric method was not appropriate. In the analytical result of surface contaminants on the tube surface, C, O, Ca, and Zr were detected, and mainly C and O dominated the proportion of contaminants. It was also found that the degree of cleaning on the tube affected the componential ratio of C and O; if the degree of cleaning is high, or if cleaning is well-conducted, the proportion of C is decreased, and the proportion of O is increased. Based on these results, optimal cleaning for application in the industry can be expected by categorizing cleaning process into three steps of Alkali cleaning, Rinsing, and Drying and by adjusting cleaning parameters in each step.

Evaluation of titanium surface properties by $Nd:YVO_4$ laser irradiation: pilot study ($Nd:YVO_4$ 레이저 조사에 따른 티타늄의 표면특성 평가: 예비 연구)

  • Kim, Ae-Ra;Park, Ji-Yoon;Kim, Yeon;Jun, Sei-Won;Seo, Yoon-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the roughness and surface alternations of three differently blasted titanium discs treated by $Nd:YVO_4$ Laser irradiation in different conditions. Materials and methods: Thirty commercially pure titanium discs were prepared and divided into three groups. Each group was consisted of 10 samples and blasted by $ZrO_2$ (zirconium dioxide), $Al_2O_3$ (aluminum oxide), and RBM (resorbable blasted media). All the samples were degreased by ultrasonic cleaner afterward. Nine different conditions were established by changing scanning speed (100, 300, 500 mm/s) and repetition rate (5, 15, 35 kHz) of $Nd:YVO_4$ Laser (Laser Pro D-20, Laserval $Korea^{(R)}$, Seoul, South Korea). After laser irradiation, a scanning electron microscope, X-ray diffraction analysis, energy dispersive X-ray spectroscopic analysis, and surface roughness analysis were used to assess the roughness and surface alternations of the samples. Results: According to a scanning electron microscope (SEM), titanium discs treated with laser irradiation showed characteristic patterns in contrast to the control which showed irregular patterns. According to the X-ray diffraction analysis, only $Al_2O_3$ group showed its own peak. The oxidation tendency and surface roughness of titanium were similar to the control in the energy dispersive X-ray spectroscopic analysis. The surface roughness was inversely proportional to the scanning speed, whereas proportional to the repetition rate of $Nd:YVO_4$. Conclusion: The surface microstructures and roughness of the test discs were modified by the radiation of $Nd:YVO_4$ laser. Therefore, laser irradiation could be considered one of the methods to modify implant surfaces for the enhancement of osseointegration.

Evaluation of a colloid gel(Slime) as a body compensator for radiotherapy (Colloid gel(Slime)의 방사선 치료 시 표면 보상체로서의 유용성 평가)

  • Lee, Hun Hee;Kim, Chan Kyu;Song, Kwan Soo;Bang, Mun Kyun;Kang, Dong Yun;Sin, Dong Ho;Lee, Du Heon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose : In this study, we evaluated the usefulness of colloid gel(slime) as a compensator for irregular patient surfaces in radiation therapy. Materials and Methods : For this study, colloid gel suitable for treatment was made and four experiments were conducted to evaluate the applicability of radiation therapy. Trilogy(Varian) and CT(SOMATOM, Siemens) were used as treatment equipment and CT equipment. First, the homogeneity according to the composition of colloid gel was measured using EBT3 Film(RIT). Second, the Hounsfield Unit(HU) value of colloid gel was measured and confirmed by CRIS phantom, Eclipse RTP(Eclipse 13.1, Varian) and CT. Third, to measure the deformation and degeneration of colloid gel during the treatment period, it was measured 3 times daily for 2 weeks using an ion chamber(PTW-30013, PTW). The fourth experiment was compared the treatment plan and measured dose distributions using bolus, rice, colloid gel and additional, dose profiles in an environment similar to actual treatment using our own acrylic phantom. Result : First experiment, density of the colloid gel cases 1, 2 and 3 was $1.02g/cm^3$, $0.99g/cm^3$ and $0.96g/cm^3$. When the homogeneity was measured at 6 MV and 9 MeV, case 1 was more homogeneous than the other cases, as 1.55 and 1.98. In the second experiment, the HU values of case 1, 2, 3 were 15 and when the treatment plan was compared with the measured doses, the difference was within 1 % at all 9, 12 MeV and a difference of -1.53 % and -1.56 % within the whole 2 % at 6 MV. In the third experiment, the dose change of colloid gel was measured to be about 1 % for 2 weeks. In the fourth experiment, the dose difference between the treatment plan and EBT3 film was similar for both colloid gel and bolus, rice at 6 MV. But colloid gel showed less dose difference than bolus and rice at 9 MeV. Also, dose profile of colloid gel showed a more uniform dose distribution than the bolus and rice. Conclusion : In this study, the density of colloid gel prepared for radiation therapy was $1.02g/cm^3$ similar to the density of water, and alteration or deformation was not observed during the radiotherapy process. Although we pay attention to the density when manufacturing colloid gel, it is sufficient in that it can deliver the dose uniformly through the compensation of the patient's body surface more than the bolus and rice, and can be manufactured at low cost. Further studies and studies for clinical applications are expected to be applicable to radiation therapy.

  • PDF