• 제목/요약/키워드: surface radiation

검색결과 2,139건 처리시간 0.03초

CAE를 이용한 파워트레인의 방사소음 저감을 위한 구조변경 (Structural Modification for the Reduction of Radiation Noise of a Powertrain Based on CAE Technology)

  • 송민근;오기석;이상권
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.439-447
    • /
    • 2008
  • One of the key elements in efforts to minimize noise radiation from a powertrain is the knowledge of the main radiating component and the relation between the surface vibration of a powertrain and the sound pressure. In this research, the powertrain model is developed based on FEM(finite element method). This model is applied to the prediction of the vibration of a powertrain by using ADAMS and the radiation noise by using BEM(boundary element method). According to this numerical analysis, the surface vibration of a powertrain is investigated as a source of radiated noise. This surface vibration is caused by the 1st order natural vibration of the cylinder block and its mode shape is the torsion mode. Therefore, this mode shape is modified to reduce the surface vibration of the powertrain. The radiation noise of the modified powertrain is also reduced to $5{\sim}12\;dB$. This modification is very successful for the noise reduction based on the CAE technology.

무작위로 거친 표면에서의 후방복사 초음파 (Ultrasonic Backward Radiation on Randomly Rough Surface)

  • 권성덕
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.9-14
    • /
    • 2005
  • 표면 거칠기가 다른 유리시편에 대해 후방 복사된 초음파 세기의 입사각 의존성(프로파일)이 측정되었다. 후방복사 세기와 레일리(Rayleigh) 표면파 속도는 표면 거칠기에 비례하였고 이 경향은 각기 초음파의 산란규칙과 경화현상으로 설명되었다. 후방복사 프로파일의 면적 역시 표면 거칠기에 민감함을 보여 표면상태에 대한 새로운 비파괴적 평가 변수의 가능성을 보였다. 레일리 각 C-스캔 기법은 화상 명도의 반전과 높은 신호대 잡음비(S/N)를 보여주었다.

3 차원 시간영역 전진속도 자유표면 Green 함수와 2 차 경계요소법을 사용한 선체의 방사포텐셜 수치계산 (Numerical Study of the Radiation Potential of a Ship Using the 3D Time-Domain Forward-Speed Free-Surface Green Function and a Second-Order BEM)

  • 홍도천;홍사영
    • 대한조선학회논문집
    • /
    • 제45권3호
    • /
    • pp.258-268
    • /
    • 2008
  • The radiation potential of a ship advancing in waves is studied using the 3D time-domain forward-speed free-surface Green function and the Green integral equation. Numerical solutions are obtained by making use of the 2nd order BEM(Boundary Element Method) which make it possible to take account of the line integral along the waterline in a rigorous manner. The 6 degree of freedom motion memory functions of a hemisphere and the Wigley seakeeping model obtained by direct integration of the time-domain 3D potentials over the wetted surface are presented for various Froude numbers.

레이저 가공시 에너지 전달과 Plume 효과 (Laser- Plume Effects on Radiation Energy Transfer in Materials Processing)

  • Kang, Kae-Myung;Kim, Kwang-Ryul
    • 한국재료학회지
    • /
    • 제12권1호
    • /
    • pp.27-35
    • /
    • 2002
  • In laser materials processing, localized heating, melting and evaporation caused by focused laser radiation forms a vapor on the material surface. The plume is generally an unstable entity, fluctuating according to its own dynamics. The beam is refracted and absorbed as it traverses the plume, thus modifying its power density on the surface of the condensed phases. This modifies material evaporation and optical properties of the plume. A laser-produced plasma plume simulation is completed using axisymmetric, high-temperature gas dynamic model including the laser radiation power absorption, refraction, and reflection. The physical properties and velocity profiles are verified using the published experimental and numerical results. The simulation results provide the effect of plasma plume fluctuations on the laser power density and quantitative beam radius changes on the material surface. It is proved that beam absorption, reflection and defocusing effects through the plume are essential to obtain appropriate mathematical simulation results. It is also found that absorption of the beam in the plume has much less direct effect on the beam power density at the material surface than defocusing does and helium gas is more efficient in reducing the beam refraction and absorption effect compared to argon gas for common laser materials processing.

국내 운량과 일조시간에 의한 태양광에너지 예측에 관한 연구 (A Study on the Estimating Solar Radiation in Korea Using Cloud Cover and Hours of Bright Sunshine)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.28-34
    • /
    • 2012
  • It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. Therefore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account cloud hours of bright sunshine. Particularly, the multiple linear regression model proposed shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of-0.26 to +0.53% and each station annual average deviation of -1.61 to +1.7% from measured values.

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

Color Texture Analysis as a Tool for Quantitative Evaluation of Radiation-Induced Skin Injuries

  • Sung Young Lee;Jin Ho Kim;Ji Hyun Chang;Jong Min Park;Chang Heon Choi;Jung-in Kim;So-Yeon Park
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.144-152
    • /
    • 2023
  • Background: Color texture analysis was applied as a tool for quantitative evaluation of radiation-induced skin injuries. Materials and Methods: We prospectively selected 20 breast cancer patients who underwent whole-breast radiotherapy after breast-conserving surgery. Color images of skin surfaces for irradiated breasts were obtained by using a mobile skin analyzer. The first skin measurement was performed before the first fraction of radiotherapy, and the subsequent measurement was conducted approximately 10 days after the completion of the entire series of radiotherapy sessions. For comparison, color images of the skin surface for the unirradiated breasts were measured similarly. For each color image, six co-occurrence matrices (red-green [RG], red-blue [RB], and green-blue [GB] from color channels, red [R], green [G], blue [B] from gray channels) can be generated. Four textural features (contrast, correlation, energy, and homogeneity) were calculated for each co-occurrence matrix. Finally, several statistical analyses were used to investigate the performance of the color textural parameters to objectively evaluate the radiation-induced skin damage. Results and Discussion: For the R channel from the gray channel, the differences in the values between the irradiated and unirradiated skin were larger than those of the G and B channels. In addition, for the RG and RB channels, where R was considered in the color channel, the differences were larger than those in the GB channel. When comparing the relative values between gray and color channels, the 'contrast' values for the RG and RB channels were approximately two times greater than those for the R channel for irradiated skin. In contrast, there were no noticeable differences for unirradiated skin. Conclusion: The utilization of color texture analysis has shown promising results in evaluating the severity of skin damage caused by radiation. All textural parameters of the RG and RB co-occurrence matrices could be potential indicators of the extent of skin damage caused by radiation.

Esophageal tolerance to high-dose stereotactic radiosurgery

  • Lee, Bo Mi;Chang, Sei Kyung;Ko, Seung Young;Yoo, Seung Hoon;Shin, Hyun Soo
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.234-238
    • /
    • 2013
  • Purpose: Esophageal tolerance is needed to guide the safe administration of stereotactic radiosurgery (SRS). We evaluated comprehensive dose-volume parameters of acute esophageal toxicity in patients with spinal metastasis treated with SRS. Materials and Methods: From May 2008 to May 2011, 30 cases in 27 patients with spinal metastasis received single fraction SRS to targets neighboring esophagus. Endpoints evaluated include length (mm), volume (mL), maximal dose (Gy), and series of dose-volume thresholds from the dose-volume histogram (volume of the organ treated beyond a threshold dose). Results: The median time from the start of irradiation to development of esophageal toxicity was 2 weeks (range, 1 to 12 weeks). Six events of grade 1 esophageal toxicity occurred. No grade 2 or higher events were observed. $V_{15}$ of external surface of esophagus was found to predict acute esophageal toxicity revealed by multivariate analysis (odds radio = 1.272, p = 0.047). Conclusion: In patients with spinal metastasis who received SRS for palliation of symptoms, the threshold dose-volume parameter associated with acute esophageal toxicity was found to be $V_{15}$ of external surface of esophagus. Restrict $V_{15}$ to external surface of esophagus as low as possible might be safe and feasible in radiosurgery.

곡면에서의 마이크로스트립 어레이 안테나의 복사 특성에 관한 연구 (A Study on the Radiation Characteristics of Microstrip Array Antennas on the Nonplanar Surface)

  • 구연건;이정수;고광태
    • 한국통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.121-136
    • /
    • 1989
  • 圓筒形 物體의 오목면과 블록면의 表面에 密着하여 設置한 마이크로스트립 어레이 안테나의 輻射 特性에 관하여 理論的 解析을 試圖하였으며, 實驗을 통하여 檢證하였다. 單一素子 안테나의 解析은 傳送線路 모델法을 適用하였고, 어레이 안테나의 理論은 曲面 위에 2次元的으로 配列된 각각의 單一素子에 대하여 座標移動과 回轉을 考慮한 座標變換法으로 解析하여 遠距離에서의 合成 電界 强度를 數値計算으로 구하였으며, 10GHz에서 4素子 竝列 어레이 안테나 및 마이크로스트립 給電線路를 設計 製作하여 여러 가지 曲率半徑에 대하여 反射損失, 共振周波數, 輻射패턴, 半 電力 비임幅, 利得 등과 같은 諸 輻射特性을 測定하겨 理論値와 比較 考察하였다. 理論에서 豫測한 바와 같이 오목면과 블록면에서 모두 曲率半徑의 減少에 따라 輻射 패턴의 비임 폭이 더 커지는 것을 確認하였으며, 曲面에서 座標變換法으로 計算한 마이크로스트립 竝列 어레이 안테나의 合成 輻射電力 패턴이 測定値와 잘 一致하였다. 아울러 曲率半徑의 變化에 따른 周波數의 變化, 入力 임피던스 및 利得의 變化는 無視할 수 있을 程度임을 確認하였다.

  • PDF

방사선치료에서 3D 프린터를 이용한 기능적 조직보상체의 제작 (Manufacturing a Functional Bolus Using a 3D printer in Radiation Therapy)

  • 이이성;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.9-14
    • /
    • 2020
  • Commercial plate bolus is generally used for treatment of surface tumor and required surface dose. We fabricated 3D-printed bolus by using 3D printing technology and usability of 3D-printed bolus was evaluated. RT-structure of contoured plate bolus in the TPS was exported to DICOM files and converted to STL file by using converting program. The 3D-printed bolus was manufactured with rubber-like translucent materials using a 3D printer. The dose distribution calculated in the TPS and compared the characteristics of the plate bolus and the 3D printed bolus. The absolute dose was measured inserting an ion chamber to the depth of 5 cm and 10 cm from the surface of the blue water phantom. HU and ED were measured to compare the material characteristics. 100% dose was distributed at Dmax of 1.5 cm below the surface when was applied without bolus. When the plate bolus and 3D-plate bolus were applied, dose distributed at 0.9 cm and 0.8 cm below the surface of the bolus. After the comparative analysis of the radiation dose at the reference depth, differences in radiation dose of 0.1 ~ 0.3% were found, but there was no difference dose. The usability of the 3D-printed bolus was thus confirmed and it is considered that the 3D-printed bolus can be applied in radiation therapy.