• 제목/요약/키워드: surface ozone

검색결과 370건 처리시간 0.027초

Surface Treatment and Dyeability of Poly(phenylene sulfide) Films by UV/O3 Irradiation (UV/Ozone 조사에 의한 Poly(phenylene sulfide) 필름의 표면처리와 염색성)

  • Jang, Yong-Joon;Jang, Jin-Ho
    • Textile Coloration and Finishing
    • /
    • 제23권4호
    • /
    • pp.284-289
    • /
    • 2011
  • Poly(phenylene sulfide)(PPS) films were photooxidized under UV/ozone irradiation. The effect of UV energy on the surface properties of the UV-irradiation PPS films were investigated by the measurement of reflectance, surface roughness, and contact angle. Reflectance decreased at the wavelength of 400nm and the surface roughness increased with increased UV energy. The improvement in hydrophilicity with increased $O_{1s}/C_{1s}$ was caused by the introduction of hydrophilic $SO_2$ bond. Surface energy increased from 46.6 to $78.3mJ/m^2$ with increased UV energy up to $21.2J/cm^2$. Also zeta potential decreased with increased UV energy. The increased dyeability to cationic dyes may be due to the photochemically introduced anionic and dipolar dyeing sites on the PPS films surfaces.he photochemically introduced anionic and dipolar dyeing sites on the PPS films surfaces.

A Novel Carbon Nanotube FED Structure and UV-Ozone Treatment

  • Chun, Hyun-Tae;Lee, Dong-Gu
    • Journal of Information Display
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 2006
  • A 10" carbon nanotube field emission display device was fabricated with a novel structure with a hopping electron spacer (HES) by screen printing technique. HES plays a role of preventing the broadening of electron beams emitted from carbon nanotubes without electrical discharge during operation. The structure of the novel tetrode is composed of carbon nanotube emitters on a cathode electrode, a gate electrode, an extracting electrode coated on the top side of a HES, and an anode. HES contains funnel-shaped holes of which the inner surfaces are coated with MgO. Electrons extracted through the gate are collected inside the funnel-shaped holes. They hop along the hole surface to the top extracting electrode. In this study the effects of the addition of HES on emission characteristics of field emission display were investigated. An active ozone treatment for the complete removal of residues of organic binders in the emitter devices was applied to the field emission display panel as a post-treatment.

The Role of Fronts on the Vertical Transport of Atmospheric Pollutants (2-D model)

  • Nam, Jae-Cheol
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.65-68
    • /
    • 2003
  • A quantitative study of the amount of air transported between the boundary layer and the free atmosphere is important for understanding air quality and upper tropospheric ozone, which is a greenhouse gas. Frontal systems are known to be an effective mechanism for the vertical transport of pollutants. Numerical experiments have been performed with a simple two-dimensional front model to simulate vertical transport of trace gases within developing cold fronts. Three different trace gases experiments have been done numerically according to the different initial fields of trace gases such as aerosol, ozone and $H_2O_2$. Trace gas field tilts to the east while the front tilts to the west. Aerosol simulation shows that pollutants can be transported out of the boundary to altitudes of about 10 km. The stratospheric ozone is brought downwards in a tropopause fold behind of the frontal surface. The meridional gradient in trace gas ($H_2O_2$) can cause a complicate structure in the trace field by the meridional advection.

  • PDF

TRACKING AND DIELECTRIC CHARACTERISTICS OF OZONE AGED SILICONE RUBBER USED FOR OUTDOOR INSULATI0N (옥외용 실리콘 고무의 장기 오존열화에 따른 내트랙킹 특성 및 유전특성 변화)

  • Lee, C.Y.;Kim, Y.H.;Lee, S.J.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1541-1543
    • /
    • 1996
  • This paper describes the results of characteristics on the tracking resistance, hydrophobicity and dielectric properties of silicone rubbers used for outdoor insulation with ozone ageing. The tracking and ozone ageing tests for this purpose ware made in according to IEC 587 and ASTM D 1149, respectively. Additionally, we investigated the surface structure of the silicone rubbers with FT-IR and SEM. From the test results, it is proven that the higher the degree of ozon ageing, the worse tracking characteristics.

  • PDF

Discharge and Ozone Generation Characteristics of a Micro-Size Nonthermal Plasma Generator Using Silicon Oxide Film (실리콘 산화막을 이용한 초소형 비열플라즈마 발생장치의 방전 및 오존발생특성)

  • Kang, Jeong-Hoon;Tae, Heung-Sik;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1816-1818
    • /
    • 1996
  • A micro-size nonthermal plasma generator, using a $SiO_2$ film as a dielectric barrier, has been studied experimentally for a high frequency ac voltage in 2LPM oxygen gas fed. The $SiO_2$ film as a micro-size dielectric barrier was made by the wet oxidation of n-type Si wafer($220[{\mu}mt]$). It can be generated ozone, as a nonthermal plasma intensity parameter, at very low level of applied voltage about 1[kV] by using the micro-size dielectric barrier. As a result, in case that have no air gap spacing i.e. surface discharge case shows relatively higher ozone concentration rather than that case of the micro-airgap spacing.

  • PDF

A Study on Characteristic of Ceramic Tube for Ozone Generation (오존발생용 세라믹 방전관 특성에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1724-1726
    • /
    • 2002
  • A novel ozonizer has been developed using a high-frequency surface discharge and a high purity alumina ceramic as its dielectric component. A thin ceramic layer, cylindrical in form, is adhered by a film-like induction electrode. An ac exciting voltage of frequency to 0.6 kHz from 1.0 kHz and $6{\sim}9kV$ peak-to-peak is applied between the electrodes to produce a stable high-frequency silent discharge for generation of ozone. A substantial reduction of the exciting voltage is also enabled by using a thin alumina ceramic layer. As a result, the ozonizer can easily produce ozone concentration($128g/m^2$ for oxygen) and power efficiency(360g/kWh for oxygen) without using a special enrichment means.

  • PDF

Electrical Properties of a CuPc Field-Effect Transistor Using a UV/Ozone Treated and Untreated Substrate

  • Lee, Ho-Shik;Cheon, Min-Woo;Park, Yong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권1호
    • /
    • pp.40-42
    • /
    • 2011
  • An organic field-effect transistor (OFET) was fabricated using a copper phthalocyanine (CuPc) as the active layer on the silicon substrate. The CuPc FET device was configured as a top-contact type. The substrate temperature was room temperature. The CuPc thickness was 40 nm, and the channel length and channel width were 100 ${\mu}m$ 3 mm, respectively. Typical current-voltage (I-V) characteristics of the CuPc FET were observed and subsequently compared to the UV/ozone treatment on substrate surface.

Ozone Generation Characteristic of Ceramic Reactor using Ti-Al-Si (세라믹 방전관의 오존 발생 특성)

  • Cho, K.H.;Park, J.Y.;Park, S.H.;Lee, D.H.;Park, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.206-208
    • /
    • 2002
  • A novel ozonizer has been developed using a high frequence surface discharge and a high purity ceramic as its dielectric component. And A cylindrical thin compound ceramic catalyst in reactor is adhered to inside of the film-like outside electrode. An ac exciting voltage with frequency to 0.6 kHz from 1.0 kHz and $4{\sim}6$ kV of peak-to-peak is applied between the electrodes to produce a stable high-frequency silent discharge for generation of ozone. A substantial reduction of the exciting voltage is also enabled by using a thin ceramic. As a result, the ozonizer can easily produce ozone concentration(50 $g/m^3$ for oxygen) and power efficiency(240 g/kWh for oxygen) without using a special enrichment means.

  • PDF

The effects of ozone therapy as an adjunct to the surgical treatment of peri-implantitis

  • Isler, Sila Cagri;Unsal, Berrin;Soysal, Fatma;Ozcan, Gonen;Peker, Elif;Karaca, Inci Rana
    • Journal of Periodontal and Implant Science
    • /
    • 제48권3호
    • /
    • pp.136-151
    • /
    • 2018
  • Purpose: The decontamination procedure is a challenging aspect of surgical regenerative therapy (SRT) of peri-implantitis that affects its success. The purpose of the present study was to determine the impact of additional topical gaseous ozone therapy on the decontamination of implant surfaces in SRT of peri-implantitis. Methods: A total of 41 patients (22 males, 19 females; mean age, $53.55{\pm}8.98years$) with moderate or advanced peri-implantitis were randomly allocated to the test group (ozone group) with the use of sterile saline with additional ozone therapy or the control group with sterile saline alone for decontamination of the implant surfaces in SRT of peri-implantitis. Clinical and radiographic outcomes were evaluated over a period of 12 months. Results: At the 12-month follow-up, the plaque and gingival index values were significantly better in the ozone group (P<0.05). Probing depth decreased from $6.27{\pm}1.42mm$ and $5.73{\pm}1.11mm$ at baseline to $2.75{\pm}0.7mm$ and $3.34{\pm}0.85mm$ at the end of the 12-month observation period in the ozone and control groups, respectively. Similarly, the clinical attachment level values changed from $6.39{\pm}1.23mm$ and $5.89{\pm}1.23mm$ at baseline to $3.23{\pm}1.24mm$ and $3.91{\pm}1.36mm$ at the 12-month follow-up in the ozone and control groups, respectively. According to the radiographic evidence, the defect fill between baseline and 12 months postoperatively was $2.32{\pm}1.28mm$ in the ozone group and $1.17{\pm}0.77mm$ in the control group, which was a statistically significant between-group difference (P<0.05). Conclusions: Implant surface decontamination with the additional use of ozone therapy in SRT of peri-implantitis showed clinically and radiographically significant. Trial registry at ClinicalTrials.gov, NCT03018795.

Investigation of Vertical Profiles of Meteorological Parameters and Ozone Concentration in the Mexico City Metropolitan Area

  • Benitez-Garcia, Sandy E.;Kanda, Isao;Okazaki, Yukiyo;Wakamatsu, Shinji;Basaldud, Roberto;Horikoshi, Nobuji;Ortinez, Jose A.;Ramos-Benitez, Victor R.;Cardenas, Beatriz
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권2호
    • /
    • pp.114-127
    • /
    • 2015
  • In the Mexico City Metropolitan Area (MCMA), ozone ($O_3$) concentration is still higher than in other urban areas in developed countries. In order to reveal the current state of photochemical air pollution and to provide data for validation of chemical transport models, vertical profiles of meteorological parameters and ozone concentrations were measured by ozonesonde in two field campaigns: the first one, during the change of season from wet to dry-cold (November 2011) and the second during the dry-warm season (March 2012). Unlike previous similar field campaigns, ozonesonde was launched twice daily. The observation data were used to analyze the production and distribution of ozone in the convective boundary layer. The observation days covered a wide range of meteorological conditions, and various profiles were obtained. The evolution of the mixing layer (ML) height was analyzed, revealing that ML evolution was faster during daytime in March 2012 than in November 2011. On a day in November 2011, the early-morning strong wind and the resulting vertical mixing was observed to have brought the high-ozone-concentration air-mass to the ground and caused relatively high surface ozone concentration in the morning. The amount of produced ozone in the MCMA was estimated by taking the difference between the two profiles on each day. In addition to the well-known positive correlation between daily maximum temperature and ozone production, effect of the ML height and wind stagnation was identified for a day in March 2012 when the maximum ground-level ozone concentration was observed during the two field campaigns. The relatively low ventilation coefficient in the morning and the relatively high value in the afternoon on this day implied efficient accumulation of the $O_3$ precursors and rapid production of $O_3$ in the ML.