• 제목/요약/키워드: surface loosening

검색결과 72건 처리시간 0.029초

Experimental study of sodium fire and its characteristics under the coupling action of columnar liquid sodium flow and concrete

  • Huo, Yan;Zou, Gao-Wan;Dong, Hui;Lv, Jian-Fu;He, Jian
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2866-2877
    • /
    • 2021
  • The complex coupling relationship between liquid sodium and concrete materials affects both the sodium fire characteristics and concrete properties through heat and chemical erosion. In this study, experiments on direct and indirect (separated by a steel plate) contact of the columnar sodium fire with the concrete surface were performed. It was found that the combustion efficiency of liquid sodium in direct contact with concrete was significantly enhanced and accompanied by intermittent explosions and splashing of small concrete fragments. The sodium fire on the surface of the concrete considerably increased the internal temperature, pore size, and distribution density of the concrete. In addition, the depth of influence on the loosening of the concrete structure was also greatly extended. The contact of liquid sodium with the concrete substantially affected its permeability resistance. The water absorption of the concrete surface was increased by more than 70% when liquid sodium directly impacted the bare concrete surface. However, the change in water absorption in the centre of the concrete was primarily affected by the duration of the external heat.

코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구 (Detorque force and surface change of coated abutment screw after repeated closing and opening)

  • 장종석;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.500-510
    • /
    • 2008
  • 연구목적: 최근 지대주 나사에 WC/C 또는 TiN 코팅이 연구되고 있으며, 이들을 금속표면에 코팅 시 마찰계수의 감소와 부식에 대한 저항, 물리적 취약함의 해소 등의 효과를 얻을 수 있으며. 코팅된 지대주 나사에서 마모와 적합도, 풀림력이 향상되었다는 결과들이 보고되고 있다. 본 연구에서는 지대주 나사에 적용된 코팅이 나사 풀림에 미치는 영향을 알아보아 임상적으로 문제가 되고 있는 지대주 나사의 풀림현상을 해소하는데 그 목적이 있다. 연구재료 및 방법: 코팅되지 않은 타이타늄 지대주 나사와 (그룹 A) WC/C (그룹 B)와 TiN (그룹 C)으로 코팅된 지대주 나사의 10회 반복 착탈시 풀림력 및 표면의 변화를 비교해본 결과 다음과 같은 결론을 얻었다. 결과: 1. 반복 착탈 전, 그룹 A는 일정한 방향성을 가진 다소 거친 표면이 관찰되었으 나 그룹 B와 그룹 C는 코팅된 입자들이 관찰되었으며 코팅층이 전체적으로 균일하고 매끈한 모양을 나타내었다. 2. 반복 착탈 전, 그룹 B에 비해 그룹 C의 표면에서 코팅 입자의 크기가 더 크고 두껍게 코팅 된 모양을 나타내었다. 3. 반복 착탈 후, 그룹 A와 그룹 B에서는 지대주 나사 표면의 마모와 변형이 관찰 되었으며 그룹 B에서는 코팅 입자의 탈락 현상을 볼 수 있었다. 4. 반복 착탈 전과 후의 지대주 나사 무게의 변화를 측정한 결과 그룹 A가 가장 큰 감소를 보였으며, 그룹 C가 그룹 B 보다 무게의 변화가 적었으나 두 그룹간 통계적으로 유의한 차이는 없었다. 5. 그룹 B와 그룹 C는 그룹 A에 비해 높은 평균 풀림력을 나타내었고 통계학적으로 유의할 만한 차이가 있었다. 6. 그룹 A에서 그룹B 와 그룹 C보다 평균 풀림력의 감소 경향이 더욱 현저 하게 나타났다. 결론: 결론적으로, WC/C 또는 TiN 코팅된 지대주 나사는 반복적인 사용 후에도 코팅되지 않은 타이타늄 지대주 나사에 비해 뚜렷한 표면 변화를 보이지 않았으며 마모에 대한 저항성이 우수하였고 높은 풀림력을 나타내었다. 따라서 지대주 나사에 WC/C 또는 TiN 코팅을 적용 시 나사 풀림의 문제점을 개선할 수 있을 것으로 사료된다.

몇 가지 용매가 양모의 저온염색에 미치는 영향 (Effect of Several Solvents on Low Temperature Wool Dyeing)

  • 도성국
    • 한국의류산업학회지
    • /
    • 제11권4호
    • /
    • pp.672-677
    • /
    • 2009
  • To reduce the dependence of wool dyeing on the temperature several solvents with different properties and structures were added to the dye bath of C. I. Acid Yellow 42. Nearly the same total solubility parameters(${\delta}_t$) of solvents as those of wool fiber and hydrophobic part of the dyestuff were needed to increase disaggregation of dye molecules, loosening the wool fiber and wickabilty of dyeing solution; besides, the large surface tension(${\gamma}$) value of the solvents and the well balanced values of the three-component Hansen solubility parameters such as dispersion(${\delta}_d$), polar(${\delta}_p$), and hydrogen(${\delta}_h$) bonding parameters were required. Among the added solvents dimethyl phthalate(DMP) and acetophenone(AP) were satisfied with these conditions and worked the most successfully in the low temperature wool dyeing. Their effectiveness proven by the dyeing rate and the activation energy ($E_a$) of the dyeing was in the order of DMP > AP > DBE > CH > M >NONE. In conclusion the total solubility parameters(${\delta}_t$), the three-component Hansen parameters and the surface tension(${\gamma}$) of DMP and AP could be the guidelines to select suitable solvents for low temperature wool dyeing.

치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가 (Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment)

  • 황준호;권성민;최성기;성미애;이규복
    • 한국표면공학회지
    • /
    • 제51권5호
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.

나사 풀림 방지를 위한 삽입 부품의 설계 최적화 (An Optimization Design of the Insertion Part for Preventing the Screw Thread from Loosening)

  • 박상근
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2356-2363
    • /
    • 2015
  • 본 연구는 볼트강도등급 10.9에 의해 추천되는 조임 토크 640~800(Nm)가 볼트-너트 체결체에 가해졌을 때 풀림 방지를 위한 코일 스프링의 삽입 및 시뮬레이션 기반 설계 최적화에 관한 것이다. 먼저 볼트-너트-코일스프링으로 구성된 조립체에 대하여 등가응력에 기반을 둔 구조 안전성 판단을 위한 조립체 구조해석 시뮬레이션을 수행한다. 그리고 이러한 해석 시뮬레이션 결과로부터 설계 개선안 도출을 위한 설계전략을 수립한다. 또한 이 전략 안에서 기존 설계의 성능을 개선해 나가는 반복 과정을 제안한다. 이 과정에서는 먼저 반응표면법을 사용하여 설계 파라미터 후보점을 찾고, 그 후보점의 반응값과 실제 시뮬레이션 결과를 비교함으로써 설계 후보점(코일스프링 감감수 N = 6)이 최적인지를 검증한다.

피에르 로빈 연속증의 치료로써 치조 보호 장치를 이용한 혀-하순 유착술 (Tongue-Lip Adhesion Using an Alveolar Protector Appliance for Management of Pierre Robin Sequence)

  • 이장원;박병윤
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.547-551
    • /
    • 2011
  • Purpose: Pierre Robin sequence is a congenital malformation in which micrognathia causes glossoptosis and airway obstruction. If conservative treatment fails, surgical procedures such as tongue-lip adhesion can be performed. However, this procedure remains a subject of debate, with favorable results being countered by reports of complications. To overcome the above limitations, we revised the traditional method of tongue-lip adhesion using an alveolar protector. Methods: Between 1992 and 2011, a total of eight patients were identified with Pierre Robin sequence and were treated with tongue-lip adhesion. Two of these eight tongue-lip adhesion procedures were performed with an alveolar protector. The operative technique for tongue-lip adhesion was similar to that described in other published reports. The alveolar protector was inserted between the ventral surface of the tip of the tongue and the lower labial sulcus. Results: Tongue-lip adhesion failed in two patients because of wound dehiscence. The primary surgical success rate was 66.7%. In the two tongue-lip adhesion procedures performed with the alveolar protector, we observed no postoperative complications. Conclusion: Resistance to traction of the tongue can be encountered with nonunionized symphysis menti, causing loosening of the traction suture through the symphysis menti. This can lead to backward positioning of tongue, resulting in dehiscence of tongue lip adhesion. The alveolar protector is a good adjunct to tongue-lip adhesion because this method avoids postoperative loosening of the traction suture and wound dehiscence. It is a simple and effective auxiliary method that yields functional improvement.

Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties

  • Venugopal, Adith;Muthuchamy, Nallal;Tejani, Harsh;Anantha-Iyengar-Gopalan, Anantha-Iyengar-Gopalan;Lee, Kwang-Pill;Lee, Heon-Jin;Kyung, Hee Moon
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.3-10
    • /
    • 2017
  • Objective: Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. Methods: AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. Results: SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Conclusions: Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.

Surface Observation of Mg-HA Coated Ti-6Al-4V Alloy by Plasma Electrolytic Oxidation

  • Yu, Ji-Min;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.198-198
    • /
    • 2016
  • An ideal orthopedic implant should provide an excellent bone-implant connection, less implant loosening and minimum adverse reactions. Commercial pure titanium (CP-Ti) and Ti alloys have been widely utilized for biomedical applications such as orthopedic and dental implants. However, being bioinert, the integration of such implant in bone was not in good condition to achieve improved osseointegraiton, there have been many efforts to modify the composition and topography of implant surface. These processes are generally classified as physical, chemical, and electrochemical methods. Plasma electrolytic oxidation (PEO) as an electrochemical route has been recently utilized to produce this kind of composite coatings. Mg ion plays a key role in bone metabolism, since it influences osteoblast and osteoclast activity. From previous studies, it has been found that Mg ions improve the bone formation on Ti alloys. PEO is a promising technology to produce porous and firmly adherent inorganic Mg containing $TiO_2$($Mg-TiO_2$ ) coatings on Ti surface, and the amount of Mg introduced into the coatings can be optimized by altering the electrolyte composition. In this study, a series of $Mg-TiO_2$ coatings are produced on Ti-6Al-4V ELI dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. Based on the preliminary analysis of the coating structure, composition and morphology, a bone like apatite formation model is used to evaluate the in vitro biological responses at the bone-implant interface. The enhancement of the bone like apatite forming ability arises from $Mg-TiO_2$ surface, which has formed the reduction of the Mg ions. The promising results successfully demonstrate the immense potential of $Mg-TiO_2$ coatings in dental and biomaterials applications.

  • PDF

볼트 결합부 풀림에 관한 마찰 특성 (The Friction Characteristics on the Loosening of Bolted Joints)

  • 박태원;신귀수
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.12-17
    • /
    • 2004
  • By using an experimental approach recently developed to determine the torque-tension relationship for bearing frictional characteristics of several typical bolted joints were studied. The experimental approach allows the direct determination of the bearing friction between the nut and its bearing surface. Detailed friction studies were made on the influences of the size and shape of the hole, the use of a slot in a bolted joint, contact area and position, and other factors such as turning speed, coating, and the use of wax on the bearing surface. The contact area and position of the washer have a marginal effect on the bearing friction. The organic coating on the nuts reduces the bearing friction significantly. Nuts with organic coating over a washer with zinc finish provide the smallest and the most consistent bearing friction. The results from the experimental investigation will be helpful for the better design of bolted joints bearing friction. The results from the experimental investigation Will be helpful for the better design of bolted joints.

임플란트용 실링 어버트먼트의 개발 및 구조해석을 통한 성능분석 (Development of a Sealing-Type Abutment for Implant and the Performance Evaluation via Structural Analysis)

  • 김정민;홍대선
    • 한국정밀공학회지
    • /
    • 제33권9호
    • /
    • pp.769-775
    • /
    • 2016
  • Currently, dental implants are widely used as artificial teeth due to their good chewing performance and long life cycle. Generally, a dental implant consists of an abutment as the upper part and a fixture as the lower part. When chewing forces are repeatedly applied to a dental implant, a gap is often generated at the interfacial surface between the abutment and the fixture, and it results in some deterioration such as loosening of the fastening screw, dental retraction and fixture fracture. To enhance the sealing performance for coping with such problems, this study proposes a new sealing-type abutment having a number of grooves along the conical surface circumference, and it carries out finite element analysis in consideration of the external chewing force and pretension between the abutment and the fixture. The result shows that the proposed sealing-type abutment shows an enhanced sealing performance in terms of the contact pressure in comparison with a conventional abutment.