• Title/Summary/Keyword: surface groups

Search Result 3,656, Processing Time 0.028 seconds

A comprehensive review of techniques for biofunctionalization of titanium

  • Hanawa, Takao
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.263-272
    • /
    • 2011
  • A number of surface modification techniques using immobilization of biofunctional molecules of Titanium (Ti) for dental implants as well as surface properties of Ti and Ti alloys have been developed. The method using passive surface oxide film on titanium takes advantage of the fact that the surface film on Ti consists mainly of amorphous or low-crystalline and nonstoichiometric $TiO_2$. In another method, the reconstruction of passive films, calcium phosphate naturally forms on Ti and its alloys, which is characteristic of Ti. A third method uses the surface active hydroxyl group. The oxide surface immediately reacts with water molecules and hydroxyl groups are formed. The hydroxyl groups dissociate in aqueous solutions and show acidic and basic properties. Several additional methods are also possible, including surface modification techniques, immobilization of poly(ethylene glycol), and immobilization of biomolecules such as bone morphogenetic protein, peptide, collagen, hydrogel, and gelatin.

A Study of Atmospheric Plasma Treatment on Surface Energetics of Carbon Fibers

  • Park, Soo-Jin;Chang, Yong-Hwan;Moon, Cheol-Whan;Suh, Dong-Hack;Im, Seung-Soon;Kim, Yeong-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.335-338
    • /
    • 2010
  • In this study, the atmospheric plasma treatment with $He/O_2$ was conducted to modify the surface chemistry of carbon fibers. The effects of plasma treatment parameters on the surface energetics of carbon fibers were experimentally investigated with respect to gas flow ratio, power intensity, and treatment time. Surface characteristics of the carbon fibers were determined by X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), Fourier transform infrared (FT-IR), Zeta-potential, and contact angle measurements. The results indicated that oxygen plasma treatment led to a large amount of reactive functional groups onto the fiber surface, and these groups can form together as physical intermolecular bonding to improve the surface wettability with a hydrophilic polymer matrix.

Capacity Change of Supercapacitor by Surface Treatment of Carbon Nanotubes (카본 나노튜브의 표면 처리에 의한 수퍼캐패시터 용량 변화)

  • Kim, Yong-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.532-536
    • /
    • 2009
  • In this study, the capacity change of supercapacitor was investigated by surface treatments of carbon nanotubes as electrode materials with various methods, such as ball-milling, $KMnO_4$ and $H_2SO_4/HNO_3$ acid mixture. Surface treatments generated a number of defects on the surface of carbon nanotubes by attacking on $\pi$ bond in graphene layer, at which carboxyl groups were introduced. These hydrophilic groups could enhance the capacity by increasing the wettability of carbon nanotube surfaces. However, a drawback of the surface treatment was the decrease of conductivity by the loss of conduction path in graphene layer due to the defect formation. The surface treatment condition should be therefore optimized between hydrophilicity increase and conductivity decrease.

The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants (수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구)

  • Kim, Sun-bong;Yim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF

A STDUY ON THE SURFACE MORPHOLOGY AND BOND STRENGTH OF DENTURE BASE RESIN TO COBALT-CHROMIUM ALLOY AFTER VARYING MODES OF SURFACE TREATMENT (COBALT-CHROMIUM 합금의 표면처리방법에 따른 레진 의치상의 접착강도 및 표면상태에 대한 연구)

  • Vang, Mong-Sook;Park, Young-Jon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.78-94
    • /
    • 1997
  • The purpose of this experiment was to determine the effects of various treatments on denture base resin to metal bond for cobalt-chromium alloy. The metal surface was treated as follows. Group 1 : Sandblasted with $50{\mu}m$ aluminum oxide. Group 2 : Sandblasted with $250{\mu}m$ aluminum oxide. Group 3 : Sandblasted with $250{\mu}m$ aluminum oxide and followed by silicoating. Group 4 : Electrochemically etched. Group 5 : treated with oxidizing solution. Group 6 : Beaded with $200{\mu}m$ retention structure and followed by silicoating. All specimens were applied with 4-META resin and were thermocycled 1000 times at temperature of $5^{\circ}C$ to $55^{\circ}C$. The effects of various surface treatments on the bond strength between 4-META resin and metal interface were measured by using the universal testing machine. All specimens were observed with SEM. The results were as follows 1. The bond strength of 4-META resin were significantly higher to Co-Cr alloy. 2. The bond strength decreased in the following orders : group 6, group 3, groups 1 and 2, group 4, group 5 and there was no statistically significant difference in bond strength among groups 1 and 2.(p>0.05) 3. The bond strength of cobalt-chromium alloy to 4-META resin were not significantly different.(p>0.05) 4. The treated surface of groups 1, 2 and 3 has more fine undercut than that of groups 4 and 5 with SEM. 5. Stable adhesion can be achieved when mechanically roughened metal surface by sandblasting than treating in an electrochemical etching and an oxidizing solution with potassium manganate.

  • PDF

The influence of commercially available carbonated water on the surface of denture based resin (국내 시판 탄산수가 의치상용 레진의 표면에 미치는 영향)

  • Kim, Hee-Kyoung;Kim, Myung-Eun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.6
    • /
    • pp.703-710
    • /
    • 2021
  • Objectives: The purpose of this study was to confirm the influence of commercially available carbonated water on denture resin by confirming the changes in the denture surface and adhesion of bacteria. Methods: Carbonated water available in the domestic market was used on specimens made of prosthetic resins. The top four products with respect to sales performance was deposited for 30 min, 24 h, and 48 h over the study groups and over one control group. The surface roughness was measured. Candida albicans was inoculated and cultured over these dentures at 37℃ on the study groups of 1 h, 24 h, and 48 h, and the number of colonies formed was measured. Results: As a result of comparing the surface roughness between groups by immersion time, the difference between groups was confirmed at 48 hours. The Trevi group showed a larger Rz than the Samdasoo group. As a result of comparing the surface roughness by time in each group, statistical significance was shown in the Ra value of the Seagram and the Rz value of the Chojung sparkling water (p<0.05). The Ra value of the Seagram was higher for 48 h than for 30 min, and the Rz value of the Chojung sparkling water was higher at 48 h than at 30 min (p<0.05). Candida albicans concentration increased over the course of immersion. Conclusions: It was confirmed that longer the specimen of the denture resin was immersed in carbonated water, more the surface roughness was affected and higher the number of attached bacteria.

Surface Characteristics of the Ground Zirconia (연삭된 지르코니아의 표면 특성)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.323-329
    • /
    • 2011
  • Purpose: This study was conducted to examine the phase transition according to the zirconia surface treatment. Methods: The specimens were divided to four groups. The first group was sintered at $1,500^{\circ}C$ and ground; the second group was sintered at $700^{\circ}C$, ground, and sintered at $1,500^{\circ}C$; the third group was sintered at $1,500^{\circ}C$, ground, and $110{\mu}m$-sandblasted; and the fourth group was sintered at $1,500^{\circ}C$, ground, $110{\mu}m$-sandblasted, treated with 9.5% hydrofluoric acid, and ultrasonic cleaner-washed for two minutes. The monoclinic fractions were measured, and the surface was observed via SEM. Results: The monoclinic fraction was $0.13{\pm}0.19%$ in the control group Zr1, $1.91{\pm}0.15%$ in the experimental group Zr2, $7.71{\pm}0.34%$ in Zr3, and $8.39{\pm}0.25%$ in Zr4. On the surface, the phase transition hardly occurred in the control group Zr1, but it increasingly occurred in the experimental groups Zr3 and Zr4. Conclusion: The monoclinic fraction was high in the experimental groups Zr3 and Zr4. The phase transition did not occur in the control group, but increasingly occurred in the experimental groups.

A Study of Designers' Cognitive Differences in Consumers' Aesthetic Preferences - Focus on Product CMF - (소비자의 심미적 선호도에서 디자이너의 인지차이에 대한 연구 - 제품 CMF를 중심으로 -)

  • Wang, Liufeng;Kim, Chee-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.4
    • /
    • pp.619-627
    • /
    • 2021
  • With growing competition in the market, more product differentiation in visual perception is needed to enhance competitive power of products. The purpose of this paper is to have a research on designer's cognitive differences in aesthetic preferences of female consumers in product CMF design, and the deviation result in different female consumer groups will be obtained based on collected data of CMF design preferences of different female consumer groups. The research method adopted is to conduct matching experiment with professional products designers as participant to test the matching through correlation analysis between designers' cognition of female consumers and their preferences and female consumer preferences on the basis of the constructed typical user roles of female consumers. The results of the research show the correlation between designers' understanding of female consumer groups and their own real needs, and the surface processing of product surface decoration is the highest aesthetic preference of female consumer groups. The research provides reference for product design industry and designers of small and medium-sized enterprises who have substantial difficulty in surface design analysis.

EFFECTS OF SURFACE TREATMENTS AND STORAGE CONDITIONS ON TARGIS/DENTIN BOND STRENGTH (Targis 표면처리가 상아질과의 전단결합강도에 미치는 영향)

  • Oh, Young-Taek;Hwang, Su-Jin;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.262-271
    • /
    • 2000
  • The purpose of this study was to estimate shear bond strength according to difference in Targis surface treatment and storage condition. 140 non-carious extracted human molars and Targis D210(Ivoclar, Liechtenstein) were used in the present study and were divided into 7 experimental groups respectively according to surface treatment of Targis. Group 1 ; No treatment, Group 2 ; $50{\mu}m$ aluminium oxide blasting, Group 3 ; 4% HF etching for 3 minutes, Group 4 ; 4% HF etching after blasting, Group 5 ; silane treatment after blasting, Group 6 ; silane treatment after 4% HF etching, Group 7 ; silane treatment after blasting and 4% HF etching. In Each group, one half of 20 specimens was stored in distilled water at $37^{\circ}C$ for 24 hours and the other half was stored at atmosphere for 24 hours respectively. Dentin surface was etched with 10% $H_3PO_4$ for 15 seconds and luting cement(Variolink II, Vivadent, Liechtenstein) was applied by manufacturer's recommendation. Shear bond strength for each group was then measured. To examine the failure patterns after shear bond test and to observe the change after surface treatment of Targis. Specimens were fabricated and observed under the SEM. Statistical analysis was performed by One Way ANOVA test and t-test. The results were as follows ; 1. The shear bond strength of the groups stored in water significantly lower than that of groups stored at atmosphere (P<0.05). 2. There was no significant difference in shear bond strength in groups stored in water (P>0.05). 3. The shear bond strength without surface treatment of Targis were lowest among all experimental groups in atmosphere condition(P<0.05). 4. There was no significant difference in bond strength between groups using the silane or not(P>0.05). 5. The groups treated by blasting, hydrofluoric acid and silane sequentially showed highest bond strength than that of other groups in atmosphere condition, but there was no significant difference(P>0.05). 6 The proportions of the specimens showing the mixed fracture failure were 20% in HF etching group and blasting + HF group, 40% in blasting + HF + silane group in atmosphere condition. All the specimens stored in water showed adhesive fracture failure.

  • PDF

Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials

  • Lee, Ki-Sun;Shin, Myoung-Sik;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.350-357
    • /
    • 2017
  • PURPOSE. The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS. One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with $50{\mu}m$ alumina, and airborne abrasion with $110{\mu}m$ silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS. Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION. Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.