• 제목/요약/키워드: surface groups

검색결과 3,652건 처리시간 0.024초

Influence of Surface area, Surface Chemical Structure and Solution pH on the Adsorption of Pb(II) Ions on Activated Carbons

  • Goyal, Meenakshi;Amutha, R.
    • Carbon letters
    • /
    • 제7권2호
    • /
    • pp.97-104
    • /
    • 2006
  • The influence of carbon surface area, carbon-oxygen groups associated with the carbon surface and the solution pH on the adsorption of Pb(II) ions from aqueous solutions has been studied using three activated carbons. The adsorption isotherms are Type I of BET classification and the data obeys Langmuir adsorption equation. The BET surface area has little effect on the adsorption while it is strongly influenced by the presence of acidic carbon oxygen surface groups. The amount of these surface groups was enhanced by oxidation of the carbons with different oxidizing agents and reduced by eliminating these groups on degassing at different temperatures. The adsorption of Pb(II) ions increases on each oxidation and decreases on degassing the oxidized carbons. The increase in adsorption on oxidation has been attributed to the formation of acidic carbon-oxygen surface groups and the decrease to the elimination of these acidic surface groups on degassing. The adsorption is also influenced by the pH of the aqueous solution. The adsorption is only small at pH values lower than 3 but is considerably larger at higher pH values. Suitable mechanisms consistent with the adsorption data have been suggested.

  • PDF

Adsorption of p-Nitrophenol by Surface Modified Carbons from Aqueous Solution

  • Goyal, Meenakshi
    • Carbon letters
    • /
    • 제5권2호
    • /
    • pp.55-61
    • /
    • 2004
  • Adsorption isotherms of p-nitrophenol from its aqueous solutions on two samples of activated carbon fibres and two samples of granulated activated carbons have been determined in the concentration range 40~800 mg/L (ppm). The surface of these carbons was modified by oxidation with nitric acid and oxygen gas, and by degassing the carbon surface under vacuum at temperatures of $400^{\circ}C$, $650^{\circ}C$ and $950^{\circ}C$. The oxidation of carbon enhances the amount of carbon-oxygen surface groups, while degassing decreases the amount of these surface groups. The adsorption of p-nitrophenol does not depend upon the surface area alone but appears to be influenced by the presence of oxygen groups on the carbon surface. The adsorption decreases on oxidation while the degassing of the carbon surface enhances the adsorption. The decrease in adsorption depends upon the strength of the oxidative treatment being much larger in case of the oxidation with nitric acid, while the decrease in adsorption on degassing depends upon the temperature of degassing. The results show that while the presence of acidic surface groups which are evolved as $CO_2$ on degassing suppress the adsorption of p-nitrophenol, the presence of non acidic surface groups which are evolved as CO on degassing tend to enhance the adsorption. Suitable mechanisms compatible with the results have been presented.

  • PDF

양극 산화와 불소 화합물로 처리한 임플랜트의 표면 특성 및 골유착 안정성에 관한 연구 (A Study on Surface Characteristics and Stability of Implants Treated with Anodic Oxidation and Fluoride Incorporation)

  • 임재빈;조인호
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.349-365
    • /
    • 2006
  • State of problem : A number of investigation about increase of surface area via various surface treatments and modification of surface constituent have been carried out. Purpose : The surface characteristics and stability of implants treated with anodic oxidation, fluoride ion incorporation, and groups treated with both methods were evaluated. Material and method : Specimens were divided into six groups, group 1 was the control group with machined surface implants, groups 2 and 3 were anodic oxidized implants (group 2 was treated with 1M $H_2SO_4$ and 185V, group 3 was treated with 0.25M $H_2SO_4$ and $H_3PO_4$ and 300V). Groups 4, 5 and 6 were treated with fluoride. Group 4 was machined implants treated with 0.1% HF, and groups 5 and 6 were groups 2 and 3 treated with 10% NaF respectively. Using variable methods, implant surface characteristics were observed, and the implant stability was evaluated on rabbit tibia at 0, 4, 8 and 12 weeks. Result : 1. In comparison of the surface characteristics of anodic oxidized groups, group 2 displayed delicate and uniform oxidation layer with small pore size containing Ti, C, O and showed mainly rutile, but group 3 displayed large pore size and irregular oxidation layer with many crators. 2. In comparison of the surface characteristics of fluoride treated groups 4, 5, 6 and non-fluoride treated groups 1, 2, 3, the configurations were similar but the fluoride treated groups displayed rougher surfaces and composition analysis revealed fluoride in groups 4, 5, 6. 3. The fluoride incorporated anodic oxidized groups showed the highest resonance frequency values and removal torque values, and the values decreased in the order of anodic oxidized groups, fluoride treated group, control group. 4. According to implant stability tests, group 2 and 3 showed significantly higher values than the control group (P<.05). The fluoride treated groups showed relatively higher values than the non fluoride treated groups and there were significant difference between group 4 and group 1 (P<.05). Conclusion : From the results above, it can be considered that the anodic oxidation method is an effective method to increase initial bone stability and osseointegration and fluoride containing implant surfaces enhance new bone formation. Implants containing both of these methods should increase osseointegration, and reduce the healing period.

Epoxy 절연재료이 표면특성에 미치는 수분처리의 영향 (Effects of Water Treating on Surface Properties of Epoxy Insulation Materials)

  • 임경범;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권10호
    • /
    • pp.553-558
    • /
    • 2000
  • This paper deals with change of contact angle, surface potential decay, surface resistivity and XPS of water-treated epoxy insulator. From the experimental results on the contact angle was reduced from $74^{\circ}$to $24^{\circ}$ due to the formation of polar hydroxyl groups on surface which was associated with intermolecular reaction between epoxy chains of three-dimensional network structure and water molecules. From the experimental results in the surface potential decay of water treated-samples, it was found that the accumulation of charge is decreased and the surface potential decay time is shortened by the interaction of polar hydroxyl groups induced on the treated surface as the increment of treatment time. The positive charging on the treated surface compared with negative charging is relatively lowered by the induction of polar hydroxyl groups. The surface resistivity was changed from $10^{15}[{\Omega}/cm^2$] to $10^{12}[{\Omega}/cm^2$] caused by water treatment. From XPS, it was found that the changes affected by the surface degradation of epoxy were caused by the generation of carboxyl groups through the chain decomposition and recombination with oxygen molecules in the air.

  • PDF

The Effect of a Kettlebell Complex Program according to the Support Surface on Lower Extremity Muscle Activity and Balance in Baseball Players

  • Dae-Han Kang;Yong-Nam Kim
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.312-316
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effect of a kettlebell complex program according to the support surface on the lower extremity muscle activity and balance of baseball players. Methods: The participants were divided into two groups; unstable support surface group 1 (11 people) performed the kettlebell complex program on an unstable support surface, and stable support surface group 2 (10 people) performed the kettlebell complex program on a stable support surface. Muscle activity was measured by surface electromyography. Dynamic balance was measured with a balance-measuring equipment. A paired t-test was used to compare groups before and after the experiment. An independent t-test was performed to determine the difference in the degree of change between the two groups before and after the experiment. Results: The intragroup comparison between stable support surface group 1 and 2 showed significant differences in muscle activity and sense of balance. In the comparison between the groups, the difference in muscle activity in unstable support surface group1 was significant in the biceps femoris and rectus femoris muscles, and significant differences were also found in the sense of balance. Conclusion: These results suggest that a kettlebell exercise on an unstable support surface is more effective in improving muscle activity and sense of balance than a kettlebell exercise on a stable support surface.

치근단절제시 노출된 상아세관의 밀폐효과에 대한 Nd : YAG 레이저의 효과 (THE EFFECT OF ND : YAG LASER ON DENTINAL TUBULE SEAL AFTER ROOT END RESECTION)

  • 신광철;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.311-320
    • /
    • 1996
  • If root and resection is done during surgical endodontic treatment, newly exposed dentinal tubules form pathways between the canal and the peripheral tissue. Nd : YAG laser was used to block this phenomenon, and its effect was studied with dye penetration and SEM techniques. 40 intact single rooted teeth were divided into 4 groups(10 each) : control group and test groups, in which retrograde cavity surface, cutting surface, retrograde cavity surface & cutting surface were treated with laser(1 watt 15pps) and finally retrograde filling with IRM was conducted. After that, they were stained with 2 % methylene blue, sectioned and evaluated by the maximum infiltration depth. And to observe surface change, they were prepared for SEM. The results were as follows ; 1. All experimental groups showed microleakage with variation in amount. 2. The 2nd group which treated both the retrograde cavity and cutting surface showed significantly less microleakage than the other groups(p<0.05). There was no significant difference between groups treated on one side only. 3. As a result of SEM observation of dentin surface, obstruction of dentinal tubules with marble shaped granules, which were different from normal dentin could be seen. Cracks could be seen also. 4. In summary of this experiment, it is thought that effort to obstruct the exposed dentinal tubules as well as retrograde cavity after root end resection is needed.

  • PDF

In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

  • Kim, Da Hye;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.39-47
    • /
    • 2017
  • Objectives: Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans) on the dental composite resins coated with three commercial surface sealants. Materials and Methods: Composite resin (Filtek Z250) discs (8 mm in diameter, 1 mm in thickness) were fabricated in a mold covered with a Mylar strip (control). In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP). The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9). Results: Group OG achieved the lowest water contact angle among all groups tested (p < 0.001). The cell surface of S. mutans tested showed hydrophobic characteristics. Group PoGo exhibited the greatest bacterial adhesion among all groups tested (p < 0.001). The sealant-coated groups showed statistically similar (groups PS and FP, p > 0.05) or significantly lower (group OG, p < 0.001) bacterial adhesion when compared with the control group. Conclusions: The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

  • Ozarslan, Mehmet Mustafa;Buyukaplan, Ulviye Sbnem;Barutcigil, Cagtay;Arslan, Merve;Tuker, Nurullah;Barutcigil, Kubilay
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.16-20
    • /
    • 2016
  • PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions $2{\times}10{\times}12mm$ from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at ${\alpha}=0.05$. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ${\Delta}E_{00}$ was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (${\Delta}E_{00}$<2.25) except Clinical Kit Groups (${\Delta}E_{00}$>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.

EFFECT OF CARBON FIBER SURFACE PROPERTIES ON FIBER-MATRIX ADHESION OF THE COMPOSITES

  • Kim Mun-Han;Park Su-Jin;Lee Jae-Rak;Choe Seon-Ung
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.40-43
    • /
    • 1999
  • Electrochemical surface treatment of PAN-based carbon fibers in acidic electrolyte has been studied in increasing the surface functional groups on fiber surfaces for the improvement of fiber-matrix adhesion of the resulting composites. According to the FT-IR and XPS measurements, it reveals that the oxygen functional groups on fibers are largely influence on the composite mechanical behaviors, whereas the nitrogen functional groups are not affected in the system. In this work, a good correlation between surface functionality and mechanical properties is established.

  • PDF

자외선 처리된 Epoxy/Glass Fiber의 표면 열화 특성에 관한 연구 (A Study on the Surface Degradation Properties of Epoxy / Glass fiber Treated with Ultraviolet Rays)

  • 이백수;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.86-91
    • /
    • 1999
  • In order to analyse the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to the wavelength of ultraviolet rays and evaluated by comparing contact angle, surface resistivity, surface potential decay, and ESCA spectrum respectively. As irradiation energy are increased, the surface properties were steeply decreased in the range of 300[nm]. But the measured values within the scope of400[nm]∼440[nm] showed a increase as compared with the untreated ones. Also, fromthe result of ESCA spectrum, it was confirmed plenty of oxygen groups on the spot showing the maximum decrease of surface properties and the existence of ether groups on the surface of coloring phase. We can conclude that the degradation phenomena on the surface of epoxy composites are dominated by the induction of ester and carboxyl groups.

  • PDF