• Title/Summary/Keyword: surface gloss

Search Result 137, Processing Time 0.021 seconds

Evaluation of Gloss Variation with a Novel Method

  • Sung, Yong-Joo;D. Steven Keller
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.73-83
    • /
    • 2002
  • Gloss is very important optical property influencing the perceived quality of the paper surface as well as the surface after printing. Although the average gloss level of paper products or printed images is important to meet end use specifications, the occurrence of gloss mottle, or non-uniformity of gloss, is often of greater concern for meeting quality requirements, especially for the high gloss paper. Gloss variation originates from the irregularities of paper surface, especially surface roughness of paper. Roughness of paper can be divided into micro-roughness (under $1\mu m$ scale in variation) and macro-roughness (over $1\mu m$ scale in variation) depending on the scale of the irregularities. A clearer understanding of the gloss variation of paper can be achieved by separating the contributions of these two scales of roughness, and characterizing them independently. In order to do this, a novel gloss measuring method was introduced. This can detect local gloss with very high resolution. The effect of macro-roughness on gloss variation, which was identified by the measurable surface topography, was separated from the total gloss variation by using this method. The effect of micro-roughness was then estimated indirectly. The local gloss variations of various paper samples were then evaluated to demonstrate the utility of this approach.

Evaluation of surface gloss of composite resins (복합레진의 표면 광택에 대한 평가)

  • Ji-Eun Byun
    • Journal of Korean Academy of Dental Administration
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

The Effect of Molding Conditions on the Surface Gloss of HIPS Molding (HIPS 성형품에서 성형조건이 표면 광택에 미치는 영향)

  • Jeong, Y.D.;Lee, M.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.81-85
    • /
    • 2000
  • The surface gloss of the injection molded part is one of the most significant point for evaluation the quality of products appearance. The effects of molding condition on the gloss of HIPS(High Impact Poly Styrene) molded part were investigated in this work. The measurements of gloss on the surface of molded part were carried out with different melt temperature, mold temperature, injection pressure and holding pressure. We observed the result of HIPS gloss compared with our's previous ABS study. The more melt and mold temperature increased, the brighter the gloss increase. Holding and injection pressure had little effect on the gloss. The gloss was effected in order of melt temperature, mold temperature, injection pressure, holding pressure.

  • PDF

The Effects of Molding Conditions on the Surface Gloss of ABS Molding (ABS(Acrylonitrile-Butadiene-Styrene) 성형품의 성형조건이 표면 광택에 미치는 영향)

  • Jeong, Yeong-Deug;Hwang, Si-Hyon;Lee, Mi-Hye
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.110-115
    • /
    • 1999
  • The surface gloss of an injection molded part is one of the most significant point for evaluating the quality of products appearance. The effects of process condition on the gloss of ABS(Acrylonitrile-Butadiene-Styrene) molded part were investigated in this work. The measurements of gloss and morphology on the surface of molded part were carried out with different melt temperature, mold temperature, mold surface roughness, injection pressure and holding pressure. Gloss had a maximum value with melt temperature in the range of 210 to 220 ${^\circ}C$ and with mold temperature 40 to 50${^\circ}C$ and with injection pressure 80~90 MPa, respectively. Melt temperature was shown to have the largest effect on gloss in our work. Gloss was not improved in the region of melt temperature 240${^\circ}C$ above and of mold temperature 60${^\circ}C$ above. It was concluded that the variation of gloss was mainly caused by rubber particles migration under shear stress not by their aggregation or necklace.

  • PDF

The mold form coating material research for the exposure concrete surface control (노출콘크리트 표면처리를 위한 거푸집 코팅재료 연구)

  • Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.137-143
    • /
    • 2010
  • This research is a comparative analysis of the surface gloss of concrete depending on the coating material added to the cast, and includes analyses of the surface gloss of specimens made of cement mortar, with and without the addition of superplasticizer. In terms of coating material, the 7th material, which is part of a liquid packaging material, was shown to have the highest gloss, and was followed by the 3rd material, which uses transparent film. As the level of gloss is shown to vary depending on the material used for the coating film, it can be interpreted that the surface gloss can differ depending on surface particles and chemical composition factors. To make a concrete surface smooth, it is more effective to use a coating material with impermeability and a highly dense surface.

Optical Property and Surface Morphology Control by Randomly Patterned Etching (불규칙 패턴 에칭에 의한 표면 형상 제어와 광학적 특성)

  • Kim, Sung Soo;Lee, Jeong Woo;Jeon, Bup Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.800-805
    • /
    • 2017
  • Randomly patterned and wet chemical etching processes were used to treat anti-glare of display cover glasses. The surface and optical properties of grain size and surface morphology controlled by randomly patterned etching and wet chemical solution etching were investigated. The surface morphology and roughness of the etched samples were examined using a spectrophotometer and a portable surface roughness (Ra) measuring instrument, respectively. The gloss caused by reflection from the glass surface was measured at $60^{\circ}$ using a gloss meter. The surface of the sample etched by the doctor-blade process was more uniform than that obtained from a screen pattern etching process at gel state etching process of the first step. The surface roughness obtained from the randomly patterned etching process depended greatly on the mesh size, which in turn affected the grain size and pattern formation. The surface morphology and gloss obtained by the etching process in the second step depended primarily on the mesh size of the gel state etching process of the first step. In our experimental range, the gloss increased on decreasing the grain size at a lower mesh size for the first step process and for longer reaction times for the second step process.

Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step (연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가)

  • Hwang, Seong-Sig;Im, Yong-Woon;Kim, Si-Chul;Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

A Review of the Topographical Causes of Gloss Variation and the Effect on Perceived Print Quality

  • MacGregor, Michael A.
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.26-43
    • /
    • 2000
  • It is well accepted that gloss variation deteriorates the print quality and there are various objective ways to measure this. Several studies now have shown that the coefficient of variation in the octave band passed printed gloss image has an excellent correlation with ratings by an expert panel using a magnitude estimation scaling method. The correlation improves when the gloss level is also taken into account beyond that of the COV. There is also evidence that the correlation would improve even more if the gloss spatial distribution could be better accounted for. We show that much (at least 80% and perhaps up to 90%) of the gloss distribution can be accounted for by the paper topography over a wide range of dimensions (scale). Recent work has supported the role that microroughness and multiple surface scattering play in the gloss distribution. This offers the promise of showing that even a greater amount of gloss variationcan be explained by topography.

  • PDF

Optical Properties Control by Surface Treatment on Display Cover Glass (디스플레이 커버 글라스의 표면 처리에 의한 광학요소 제어)

  • Kim, Sung Soo;Hwang, Jai Suk;Jeon, Bup Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.9
    • /
    • pp.607-614
    • /
    • 2015
  • To provide the clear images from the direct light on electrical board and display devices, anti glare treatment of display cover glass is needed. In this study, the effects of surface treatment temperature, concentration, and etching solution coating thickness of the gel phase on optical elements control such as gloss, haze of reflected light and transmittance, were investigated. Cover glasses were treated at different coating thickness and additive concentration. The optical properties were examined using spectrophotometer, gloss and haze meter. The surface morphology and roughness were measured by the optical microscope and Ra measuring instrument. The etching rate and surface morphologies were dramatically affected by the concentration of acid additive in the viscous gel because of re-crystallization of components in the etching solution, hydrogel formation and coagulant after coating on glass substrate. In our experimental range, cover glass which is surface-treated with various optical properties as well as the morphology uniformity was obtained; in particular, optical properties could be controlled by etching solution coating thickness of the gel phase and the concentration of additive. The gloss was depended on the surface roughness and it showed the linear relationship between optical transmittance and haze of reflected light, respectively.

Effect of Calendering Variables on the Properties of Coated paper (캘린더 처리조건이 도공지 품질에 미치는 영향)

  • 이용규;김창근;이광섭
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.49-57
    • /
    • 2001
  • This study was performed to identify the effect of calendering variables on the properties of coated paper such as sheet gloss, surface roughness, opacity, etc. The effect of calendering variables including the number of nips, pressure, machine speed and moisture content on the properties of coated paper was investigated. The calender was installed with two steel rolls and one cotton-made roll. With this calender, the coated sheets were passed through the calender from 1 to 4 times, applying the linear pressure on calender rolls, 5 through 100kg/cm and operating the machine speed 3 to 12m/min. Also, the moisture content of coated sheet was varied about 5 and 10%. It was found that sheet gloss and surface roughness of coated paper was increased with increasing the number of passing nips, linear roll pressure and the moisture content of coated paper. But it was shown that the opacity and brightness of coated paper were decreased under the above conditions due to the blackening. It was also suggested that the soft nip possibly increased the thermoplasticity of coating layer with the heat of steel roll, resulting in the reinforcement of surface properties positively. The sheet gloss and surface roughness of coated paper could be improved by the longer dwell time over the rolls.

  • PDF