• Title/Summary/Keyword: surface electromyography

Search Result 496, Processing Time 0.027 seconds

The Different Muscle Activation of Upper Extremity and Core Muscle by the Changes of Leg Support Surface during Push-up Exercise

  • Kim, Sun-Uk;Kim, Seong-Bin;Yeo, Sang-Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.195-200
    • /
    • 2016
  • Purpose: This study was designed to evaluate the effects of the different condition of leg support surface on the upper extremity and core muscle activity during the push-up exercise. Methods: Fifteen healthy subjects that were practicable push-ups were recruited in this study. Subjects were instructed the push-up exercise in the different condition of the leg support surface. Each condition of support surface was set to the high and lower, and the unstable and stable condition. Muscle activation was measured by using the surface electromyography (EMG), and recorded from the triceps brachii, serratus anterior, latissimus dorsi, rectus abdominis, abdominal external oblique, and erector spinea muscle. Results: In the results of experiments, there was no significant difference of muscle activation in upper extremity between the high unstable and high stable support surface. By contrast, muscle activation of the rectus abdominis and abdominal external oblique was significantly higher in the low unstable support surface, compared with those of the low stable support surface. It is well known that the core muscle was important to stabilization of trunk stability. Conclusion: This result demonstrates that the low and unstable support surface for the lower extremity was suited for training of core muscle for trunk stabilization during the push-up exercise.

Comparison of Bimanual and Unimanual Movements on Muscle Activity in Healthy Adults (정상인에서 양손 및 한손 움직임 시 근활성도 비교)

  • Kim, Taehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.75-81
    • /
    • 2018
  • Purpose : The aim of this study was to compare the muscle activities of thumb and wrist during unimanual, bimanual symmetric and bimanual reciprocal movements using surface electromyography. Method : Thirty-six participants were involved in this study. Two blocks were used to perform unimanual, bimanual symmetric and bimanual reciprocal movements of thumb and wrist. Muscle activities in the flexor pollicis brevis, abductor pollicis brevis, extensor carpi radialis and flexor carpi radialis were measured using an surface EMG system. Result : For the flexor pollicis brevis and abductor pollicis brevis, significant difference in the muscle activity were found among the unimanual, bimanual symmetric and bimanual reciprocal movement. For the extensor carpi radialis and flexor carpi radialis, the unimanual movement significantly different from the bimanual symmetric and reciprocal movements. Conclusion : Both the thumb and wrist, bimanual symmetric and reciprocal movements were more efficient than the unimanual movement. Moreover, with regard to the thumb, the bimanual reciprocal movement was more efficient than the bimanual symmetric movement.

Surface Electromyographic Measure in Patients with Winging Scapula (익상견갑 환자의 표면근전도 검사)

  • Kim, Chul Hyun;Lee, Yang Soo;Lee, Yong Boem;Rho, Jae Hyun;Lee, Zee Ihn
    • Annals of Clinical Neurophysiology
    • /
    • v.7 no.2
    • /
    • pp.124-126
    • /
    • 2005
  • The effect of serratus anterior dysfunction is seen in the scapular winging. We report 2 cases with winging scapula clinically but do not reveal denervation potentials in needle electromyography. Surface myoelectric measurements of median frequency and root mean square values show difference in fatigability and amplitude in affected side.

  • PDF

Trunk Stabilization Muscle Activity in Chronic Low Back Pain Patients during One Leg Stance (만성요통환자의 한발서기 시 체간 안정화 근육의 활성화 변화)

  • Min, Dong-ki
    • Journal of Korean Physical Therapy Science
    • /
    • v.21 no.1
    • /
    • pp.13-20
    • /
    • 2014
  • Purpose : The purpose of this study was to analyze and compare the surface electromyography(EMG) activity of trunk region muscle between normal subjects and chronic low back pain(CLBP) patients during one leg stance. Methods : The subjects were 27 people, were consisted of 12 subjects who don't have low back pain and 15 subjects who have low back pain from 19 to 28 year of age(mean age 22.22). We used surface EMG to evaluate the activity of the Rectus abdominis, External abdominal oblique, Quadratus lumborum, Gluteus medius muscle. We used independent two samples t-test for statistical data. Results : The result of this study showed that the maximal voluntary isometric contraction(%MVIC) ratio of the trunk muscles was higher in patients with CLBP than in normal subject. But there were no statistically significant differences. There were statistically significant differences of the activity of the Quadratus lumborum, Gluteus medius muscle(p<0.05).

  • PDF

Isolated Activation Ratio of the Quadriceps Femoris Muscle on Different Support Surfaces During Squat Exercise (스쿼트 운동 시 지지면 변화에 따른 넙다리네갈래근의 독립활성비율)

  • Kim, Yong-Hun;Kim, Byeong-Jo;Park, Du-Jin
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.125-132
    • /
    • 2018
  • Purpose: The aim of this study was to investigate the isolated activation ratio of the quadriceps femoris muscle on different support surfaces during squat exercise. Methods: Twenty participants (10 males and 10 females) voluntarily agreed to participate in the research after receiving an explanation about the purpose and process of the study. Each participant performed squat exercises on three different support surfaces (a flat surface, a form roller, and an unstable surface). Muscle activities of the rectus femoris (RF), vastus medialis (VM), and vastus lateralis (VL) were measured by electromyography. The isolated activation ratio of the quadriceps femoris muscle was calculated using the %isolation formula. Results: For the squat exercise, the %isolation value of the VM was significantly higher on the unstable surface than on the flat surface and form roller. In contrast, the %isolation values for the RF for the squat exercise were significantly higher on the flat surface and form roller than on the unstable surface. There was no significant differences in the %isolation values of the VL on the three different surfaces. Conclusion: The findings indicate that squat exercise on different surfaces results in differential activation of the quadriceps femoris muscle, which suggests that squat exercise on a multi-directional unstable surface could increase the isolated activation ratio of the VM.

A Study of the Electrical Properties of the Buccal Area using Facial Surface Electromyography

  • Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.

A Quantitative Analysis of Electromyography Obtained from Subjects Performing Seated Tasks (앉은 자세로 행하는 작업에서 측정된 근전도의 정량적 해석)

  • Son, Kwon
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.9-18
    • /
    • 1992
  • This paper describes a quantitative analysis of electromyography (EMG) measured from seven subjects performing four seated dynamic tasks. EMG signals were mom- bored using 15 surface electrodes which were placed on selected trunk and lower extrmity muscles of the right side of the body. Each EMG signal was then processed through rectification, integration, and filtering. Based on the maximum level of the processed EMG, it was found that the trunk and ankle muscles play an important role on the postural control during the seated tasks.

  • PDF

Study on an Electrode Attachment Method Suitable for Underwater Electromyography Measurements

  • Han, Seul-ki;Park, Jung-seo;Nam, Taek-gil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.95-98
    • /
    • 2015
  • PURPOSE: This study was conducted to devise a method of preventing water infiltration into the surface electrodes during EMG measurements underwater and on the ground and to check the reliability of Electromyography (EMG) measurements when underwater. METHODS: Six healthy adults were selected as subjects in this study. The measurements in this study were conducted in pool dedicated to underwater exercise and physical therapy room in the hospital building. An MP150 (Biopac Systems, US, 2010) and a BioNomadix 2-channel wireless EMG transmitter (Biopac Systems, US, 2012) was used to examine the muscle activity of rectus femoris, biceps femoris, tibialis anterior, gastrocnemius of dominant side. The subjects repeated circulation tasks on the ground for more than 10 min for enough surface electrode attachment movement. After a 15-min break, subjects performed the circulation task underwater(water depth 1.1m, water temperature $33.5^{\circ}C$, air temperature $27^{\circ}C$), as on the ground, for more than 10 min, and the MVIC of each muscle was measured again. SPSS v20.0 was used for all statistical computations. RESULTS: The maximum voluntary isometric contraction (MVIC) values between the underwater and on the ground measurements showed no significant differences in all four muscles and showed a high intraclass correlation coefficient (ICC) of >0.80. CONCLUSION: We determined that EMG measurements obtained underwater could be used with high reliability, comparable to ground measurements.

Correlation between Surface Electromyography and Conventional Electromyography in Facial Nerve Palsy (안면마비 환자에서 표면 근전도 검사와 통상적 근전도 검사간 상관관계)

  • Jang, Haneul;Yoo, Seung Don;Lee, Jong Ha;Soh, Yunsoo;Kim, Dong Hwan;Chon, Jinmann;Lee, Seung Ah;Kim, Hee-Sang;Yun, Dong Hwan;Kwon, Jung Ho
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.84-90
    • /
    • 2018
  • Objective: To assess the correlation between surface electromyography (SEMG) and conventional EMG in patients with facial nerve palsy. Additionally, compare the discomfort and the time required by the patients in two methods. Method: 36 patients with facial palsy were given nerve conduction studies (NCS) via conventional EMG. Then, the peak root mean square (RMS) values were obtained from the SEMG. We also recorded visual analogue scale (VAS), House-Brackmann scale, and the time required for the examination. Results: Pearson's correlation coefficient between the amplitude loss ratio of the RMS values obtained by SEMG compared to the unaffected side (RSEMG) and the amplitude loss ratio of CMAP amplitudes compared to the unaffected side (RCMAP) was 0.567 at the frontalis, 0.456 at the orbicularis oculi, 0.393 at the nasalis, and 0.437 at the orbicularis oris. An increase in RSEMG is positively correlated with an increase in RCMAP. The mean VAS score with conventional EMG was $3.55{\pm}1.42$, whereas that experienced when using SEMG was $0.11{\pm}0.52$ and the mean time required for conventional EMG was $610{\pm}103.84$ seconds, while that required for SEMG was $420{\pm}86.32$ seconds. Conclusion: This study demonstrated a significant positive correlation between facial muscle activities as measured by SEMG and conventional EMG in patients with facial nerve palsy. SEMG has the benefits of being more comfortable and faster when diagnosing facial palsy.

The effects of $Yanggn\bar{u}ngch'\check{o}n(G34)$ acupuncture on the muscle fatigue (양릉천(陽陵泉) 자침(刺針)이 근피로에 미치는 영향)

  • Kwon, Ho-Young;Kim, Jeong-Hwan
    • Korean Journal of Acupuncture
    • /
    • v.25 no.2
    • /
    • pp.115-123
    • /
    • 2008
  • Objectives : The aim of this stuty is to investigate the effect of acupuncture at $Yanggn\bar{u}ngch'\check{o}n$ (G34) on the muscle fatigue. Methods : Subjects were asked to perform the elbow flexion and extension to induce the muscle fatigue. Sample group of 16 healthy subjects had acupuncture on $Yanggn\bar{u}ngch'\check{o}n$ (G34) during the resting time, while control group of 13 healthy subjects did not. Surface electromyography (sEMG) was measured after exercise and rest to record muscle fatigue. Results : Acupuncture at $Yanggn\bar{u}ngch'\check{o}n$ (G34) is effective for decreasing the muscle fatigue.

  • PDF