• Title/Summary/Keyword: supply rate

Search Result 2,638, Processing Time 0.028 seconds

C-rate based electrical characteristics and equivalent circuit modeling of 18650 cylindrical Li-ion battery for nuclear power plant application (원전 비상전원 적용성 판단을 위한 다양한 C-rate 기반 원통형 리튬이온 배터리의 전기적 특성분석 및 모델링)

  • Kim, Gunwoo;Park, Seongyun;Park, Jinhyeong;Kim, Jonghoon;Park, Sungbaek;Kim, Youngmi
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.667-674
    • /
    • 2019
  • The recent incidents of Nuclear Power Plant(NPP) gave rise to a total power outage caused by the loss of the functions of the off-site and the emergency power supply. Currently, emergency power supply of NPP have been taken into account by Li-ion batteries instead of existing lead-acid batteries. In order to judge the applicability of the cylindrical Li-ion battery, it is necessary to analysis the results of various electrical tests. This paper investigates the basic electrical characteristics test of three types of cylindrical batteries in order to select the most suitable battery and estimate state of battery through equivalent circuit model and propose method to solve the problem.

Water Quality Management of Simple Piped Water Supply System and Its Satisfaction of the Residents (簡易上水道의 水質管理實態와 給水利用住民의 滿足度)

  • Chae, Han-Uk;Park, Jae-Yong;Moon, Hyo-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.

  • PDF

A Study on the Recirculation Flow Characteristics with the Change of Shape in a Flue Gas Recirculation Device using Coanda Nozzle (코안다 노즐을 이용한 배기가스 재순환 장치의 형상에 따른 재순환 유동 특성에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hun;Kim, Dae Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.1-6
    • /
    • 2019
  • The purpose of the present study is to elucidate flue gas recirculation device for reduction of nitrogen oxides using coanda nozzle without adopting additional power driving fan in a waste incinerator. The characteristics of the exhaust gas recirculation flow rate and the average temperature change at the outlet of the mixed gas were investigated according to the change of air supply nozzle gap and the position of air supply nozzle. When the gap of the air supply nozzle was changed to 3.22, 4.03, and 4.84 mm, the largest recirculation flow ratio, which is the ratio of exhaust gas recirculation flow rate and air supply flow rate, was 2.227 for the case with 3.22 mm and its mean temperature at outlet was $594.8^{\circ}C$. When the position of the air supply nozzle changes to the front position, neck position, and expansion position of the coanda nozzle neck, the recirculation flow ratios at the forward position and the neck position were nearly almost the same value, 1.843, and 1.696 at the expansion position, their mean temperatures were $559.8^{\circ}C$ and $544.3^{\circ}C$, respectively.

Evaluation of High Flux Combined with Pretreatment Process for Application of Decentralized Water Supply System with Ceramic Membrane (세라믹 분리막의 분산형 용수공급 시스템 적용을 위한 전처리 연계공정의 고플럭스 평가)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.61-72
    • /
    • 2018
  • In this study, applicability of the decentralized water supply system were investigated by the high flux evaluation using ceramic membrane with combined pretreatment process. A) filtration process increased the transmembrane pressure of 1.4 kPa and 89.5 kPa on 2 and $5m^3/m^2{\cdot}d$ of filtration flux, respectively, the physical backwashing recovery rate were less than 28.6%. The (B) Coag./Floc. - Sedi. combined process with 4 mg / L of A-PAC showed that the transmembrane pressure increased to within 6 kPa, the physical backwashing recovery rate was over 37.9 % higher than (A) Filtration process. (C) Coag./Floc. combined process showed an increase of transmembrane pressure compared with (B) Coag./Floc. - Sedi. combined process, physical backwashing recovery rate was over 84%. As a result of the membrane fouling analysis using the resistance in series model, the combined pretreatment process showed that the cake resistance (Rc) was more than 92% at membrane filtration flux of $2m^3/m^2{\cdot}d$. In the (C) Coag./Floc. combined process, cake resistance(Rc) was over 86% on high flux conditions. The coagulation floc contained in influent was removed by the membrane, and the cake layer formed with the removed floc was identified as reversible fouling resistance which could be recovered by physical backwashing. The decentralized water supply system, which has the limitation of site area and installation space, is considered to could be operation of high flux of ceramic membrane by applying (C) Coag./Floc. combined process without sedimentation process.

Electromagnetic Analysis on the Torque Motor of Servo Valve for the Fuel Supply System of Auxiliary Power Unit (보조 동력 장치 연료 공급용 서보밸브의 토크모터 전자기 해석)

  • Chang, Se-Myong;Jang, Gang-Won;Jeong, Heon-Sul;Rhee, Dong-Ho
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • As a main part of an utility helicopter, the APU(Auxiliary Power Unit) has a solenoid valve system operated with a torque motor, which controls the flow rate in the fuel supply system. In this paper, we solved the Maxwell potential equations to analyze the electromagnetic force in the torque motor, and some additional analytic methods are used to compute the quantity of torque produced by the torque motor for the given circuit current. For the convenience, small displacement is assumed, and only magneto-static problem is considered for the two-dimensional cross section. The result will be compared with the three-dimensional analysis that will be studied in the near future.

  • PDF

A STUDY ON A PROBABILISTIC MULTI-LOCATION PROBLEM IN A TWO-ECHELON LOGISTIC SYSTEM FOR DETERIORATING ITEMS

  • Hwang, Heung-Seok;Hwang, Hak
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 1981
  • A special case of the probabilistic multi-location problem is studied in a two-echelon logistic system for deteriorating items. The objective is to determine the location of the minimum number of supply centers among a discrete set of location sites of supply centers, such that the probability each retailer being covered by some supply center is not less than a specified value. A logistic cost is introduced as performance measure of the system, and leads us to analyze the impact of deterioration rate on the location problem. The results obtained from numerical examples are discussed, which provides effective guidelines that can be used for the logistic managerial decisions.

  • PDF

The Introduction of #2 HVDC SYSTEM (육지-제주간 2차 HVDC SYSTEM 개요)

  • Jang, Suk-Han;Yoo, Sung-Hwan;Shin, Myoung-Sik;Lee, Gyu-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.107-109
    • /
    • 2008
  • Cheju-Haenam HVDC transmission system start it's commercial operation since 1998. JEJU island is supplied with it's about 45% of total electric power from main land with HVDC link. In JEJU island, the demand of electric power is growing every year. With a current power supply, electric power reserve rate will be below the recommended one. For a stable power supply to JEJU island, KEPCO start a construction of #2 HVDC transmission system. This report is for introduction and understanding of #2 HVDC system which will be installed between JEJU island and main land. This report includes a specification of converter station and DC cable. KEPCO expect that this system will solve the power supply problem and maximum wind power plant capacity problem as well.

  • PDF

Elevator's Car Auxiliary Power System using the Contactless Power Transmission Method (비접촉 전력전송방식을 이용한 엘리베이터 카 보조 전원시스템)

  • Lim, Eung-Kyu;Rho, Sung-Chan;Kim, Soo-Hong;Kim, Ji-Min;Kim, Youn-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.80-84
    • /
    • 2008
  • In this paper, we have posed contactless power supply method using the contactless transformer with multiple primary winding. Also, the system uses resonant frequency tracking method for safe power supply at the elevator's car. The proposed system has been verified by the simulation using ICA4 and Maxwell. The contactless power transmission system is designed for 5[kW] rate.

Design of Smart Controller using Intelligent Algorithm for Wet Station (지능형 알고리즘을 이용한 Wet Station용 스마트 제어기 설계)

  • 홍광진;김종원;조현찬;김광선;김두용;조중근
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.67-70
    • /
    • 2004
  • Semiconductor Wet Station has a very important place in semiconductor process. It is important that to discharge chemical with fit concentration and temperature using chemical supply system for clean process. The chemical supply system which is used currently is not only difficult to make a fit mixing rate of chemical which is need in clean' process, but also difficult to make fit concentration and temperature. Moreover, it has high stability but it is inefficient spatially because its volume is great. We propose In-line System to improve system with implement analysis of fluid and thermal transfer on chemical supply system and understand problem of system.

  • PDF

A Study on the Change of the Housing Supply and the Residential Density in Daegu (대구시의 주택보급과 주거밀도변화에 관한 연구)

  • 권용일
    • Journal of the Korean housing association
    • /
    • v.12 no.2
    • /
    • pp.151-160
    • /
    • 2001
  • The purpose of this study is for investigating characteristics of changing residential density and relations between housing supply and redistribution of population in Daegu. As a result, the following conclusions could be made. First, land development and housing supply have important effect on distribution of population and changing residential density in Daegu. Second, according to massive site development to meet the housing demand in suburban area, the suburbanization has begun and build-up-area grows faster, so centre of gravity of residential density increasing rate has moved to the suburban. Third, the inner district and the district near urban centre will need remodelling or redevelopment project in the near future.

  • PDF