• 제목/요약/키워드: supply rate

검색결과 2,638건 처리시간 0.033초

A Study on The Energy Conservation System in House for reducing the Environmental Load (환경부하 저감을 위한 주택의 에너지절약 시스템에 관한 연구 -소형코제너레이션시스템과 태양광발전시스템을 적용한 성능평가-)

  • 정진현
    • Journal of the Korean housing association
    • /
    • 제11권1호
    • /
    • pp.159-169
    • /
    • 2000
  • This study was examined the energy conservation and the environmental value through the computer simulation employing the micro cogeneration system and the photovoltaic power generation system in house. The results of this study were as follows:1. In case of the micro cogeneration system. With the conditions of 'the electric produced by the micro cogeneration system was not sold to the electric power company', 'control quantity of commercial power supply was 10%' , 'operating time was 6 hour', 'minimum load rate of generator was 50%', and 'having a storage tank', the micro cogeneration system was superior compare to the comparative system in 2.4% of the energy conservation and 4.18% of the environmental value. 2. In case of the photovoltaic power generation system. 1) The 66.9% of total generated electric power from the photovoltaic power system was sold to the electric power company. That is, it could help to preserve the electric power from commercial power supply.2) There is a possibility of cutting the fair rate of electric power.

  • PDF

Properties of positive real systems in time domain (양실 시스템의 시간영역에서의 특성)

  • Shim, Deok-Seon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제4권2호
    • /
    • pp.157-162
    • /
    • 1998
  • This paper provides some properties of positive real systems in time domain. It is well-known that a positive real system and a bounded real system are closely related by bilinear transform in a frequency domain. By using supply rate and storage function, we show that a positive real system can be transformed into a bounded real system, and that a positive real system can be transformed into another positive real system with in a time domain. Also, we show that an ESPR(extended strictly positive real) system can be decomposed into a feedback system of lossless positive real system and another ESPR system. These results may be used to design an output feedback controller for mixed H$H_2$ESPR problem.

  • PDF

Assessment of Reliability in the Distribution System of an Industrial Complex

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.201-207
    • /
    • 2007
  • As the power industry moves towards open competition, there has been a need for methodology to evaluate distribution power system reliability by using customer interruption costs, particularly in power supply zones under the competitive electricity market. This paper presents an algorithm to evaluate system average interruption duration index, expected energy not supplied, and system outage cost taking into consideration failure rate of the distribution facility and industrial customer interruption cost. Also, to apply this algorithm to evaluate system outage cost presented in this paper, the distribution arrangement of a dual supply system consisting of mostly high voltage customers in an industrial complex in Korea is used as a sample case study. Finally, evaluation results of system interruption cost, system average interruption duration index, and expected energy not supplied in the sample industrial complex area are shown in detail.

Analysis of the Regional Inequalities of Renewable Energy Resources using Gini's Coefficients (지니계수를 이용한 시군구별 신재생에너지 자원의 불균등성 분석)

  • Lee, Jimin
    • Journal of Korean Society of Rural Planning
    • /
    • 제22권2호
    • /
    • pp.109-119
    • /
    • 2016
  • Most of countries are trying to increase the supply of renewable energy as the substitute of the fossil energy for reducing greenhouse gas emissions. However, renewable energy sources account for only about 3.86% of the total Korea primary energy supply. To increase the rate of renewable energy in Korea's energy consumption, various policies for expanding the use of renewable energy should be applied. Also these policies should be consider renewable energy resources distribution and regional inequality. In this study, the potentials of photovoltaic, wind power and bioenergy from rice straw, livestock waste and food waste are calculated and the distribution characteristic and regional inequalities are analyzed using Gini's coefficient and Gini decomposition method. As the results, technical potentials of photovoltaic and wind power of city region(Gu) has more potential rate than theoretical potentials. Livestock waste has the most unequal distribution (Gini's coefficient: 0.617) among renewable resources.

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

Health Capacity to Work at Older Ages in South Korea: Estimates and Implications for Public Pension Policies

  • KIM, DOHYUNG
    • KDI Journal of Economic Policy
    • /
    • 제41권2호
    • /
    • pp.41-58
    • /
    • 2019
  • Health capacity to work for the elderly is an essential piece of information for designing social policies in an aging society. Here, we assess the health capacity to work of older men in South Korea and provide a cross-country comparison. Following the methodology proposed by Milligan and Wise (2012), which uses the cohort mortality rate as a proxy for overall health status, we quantify the additional employment capacity of current older men in reference to the mortality-employment relationship of a generation ago. Despite the high employment rate of older men in South Korea, we find substantial additional employment capacity among older men (those aged 55 or more) as of 2016 comparable in size to those found in other advanced countries. We also find evidence that older men are not merely capable of working but are also willing to work, and many of them are increasingly combining pension income and work. These findings suggest that labor supply disincentives for older men embedded in public pension systems in South Korea need to be thoroughly reexamined and adjusted accordingly lest they should inhibit the labor supply of older workers.

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제21권4호
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

A Study on the Reliability of Superconducting Fault Current Limiter and Adjacent Distribution Equipments (초전도한류기와 인근 배전설비의 신뢰도에 관한 연구)

  • Bae, In-Su;Kim, Sung-Yul;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제58권11호
    • /
    • pp.2122-2127
    • /
    • 2009
  • This study presents the failure rate and repair rate of Superconducting Fault Current Limiter(SFCL) and adjacent distribution equipments. When the fault current penetrated SFCL, the supply of electric power to the customers can be partly continued. It is expected that SFCL makes to improve the reliability index of customers. Contrary to the expectations, the series connection between SFCL and distribution system could deteriorate the reliability index. To evaluate the reliability index in the distribution system including SFCL, the failure rate and repair rate of SFCL are required as well as that of distribution equipments. Also, the insertion of SFCL makes to change the failure rate and repair rate of adjacent equipments. This study proposes a method to calculate the failure rate and repair rate of a component combining SFCL and adjacent equipments.

Estimation of the Virtual Water Consumption for Food Consumption and Calorie Supply (식품 소비 및 칼로리 공급 변화에 따른 가상수 소비량의 변화 분석)

  • Lee, Sang-Hyun;Choi, Jin-Yong;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제57권3호
    • /
    • pp.77-86
    • /
    • 2015
  • The agricultural water management generally has focused on water resources for crop production but it could be affected by the food consumption pattern. The aim of this study is to estimate virtual water consumption for food consumption and calorie supply using the water footprint and virtual water concept. In addition, we estimated the virtual water requirements for increasing the food and calorie self-sufficiency adjusted by the government for food security. About $330.0m^3/cap/yr$ of virtual water was consumed for the main foods consumption in 1985, and it was increased to $450.0m^3/cap/yr$ in 2010. The rate of virtual water consumption by meats consumption was 28 % in 1985 but it was increased to 54 % in 2010. In other words, the total virtual water consumption by foods consumption was increased from 1985 to 2010 with the high rate of meats consumption. The average $1.29m^3$ of virtual water was consumed for supplying 1 calorie per capita in 2010 but about $10.1m^3/cal$ of virtual water was consumed by only bovine meats consumption. The food self-sufficiency is the main factor for food security in Korea. About $46.5Mm^3$ and $393.9Mm^3$ of virtual water were required in order to increase the food and calorie self-sufficiency of wheat by 1 % individually. This study showed the water consumption was related to food consumption and calorie supply pattern, and these results could be used as the indices for the agricultural water management considering the change of eating habit and food security.

An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone (제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석)

  • You, Woo Jun;Ko, Gwon Hyun;SaKong, Seong Ho;Nam, Jun-Seok;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2013
  • This study is experimentally analyzed to extract the major parameters affecting the performance of the smoke-control system and the relations of pressure difference between vestibule and supply air pressure zone effect of supply mass flow rate and leakage area in the smoke-control zone. To obtain this, the mock-up building of three-story scale with a total of 10 compartments was constructed, and several apparatus were also installed for in-situ measurement of the ventilation flow rate, pressure difference between compartments, smoke defensive air velocity, the opening-closing force of door, etc. This article show that pressure difference in the smoke-control zone is significantly related with leakage area of vestibule in low pressure region, leakage area of supply air pressure in over pressure region and both of them in pressure control region when the pressure control range of damper is 45 Pa~55 Pa.