• Title/Summary/Keyword: supply rate

Search Result 2,638, Processing Time 0.031 seconds

Agent Based Modeling and Simulation of Structural Hole Based Order Allocation Strategy (구조적 공백 기반 주문 분배 전략의 에이전트 기반 모델링 및 시뮬레이션)

  • Kim, Dae-Young;Kang, Bok-Young;Kang, Suk-Ho
    • Korean Management Science Review
    • /
    • v.29 no.1
    • /
    • pp.153-168
    • /
    • 2012
  • Order allocation is one of the most important decision-making problems of firms having significant influences on performances of themselves and the whole supply chain. Existing researches about order allocation have mainly focused on evaluating capabilities of directly connected suppliers so that it is hard to consider effects and interactions from undirected connections over multiple lower-layers. To alleviate the limitation, this paper proposed a novel approach to order allocation using structural hole. By applying the concept of structural hole to the supply network, we could evaluate the structural supplying powers of firms with respect to both of direct and indirect connections. In the proposed approach, we derived a methodology to measure the potential supplying power of each firm by modifying the effective size as one of the measurements of structural hole and then, proposed its application, the structural hole based order allocation strategy. Furthermore, we conducted the agent based modeling of supply chain to perform the decision-making process of order allocation and simulated the proposed strategy. As a results, by coping with the variance of demand more stably, it could improve the performance of supply chain from the aspects of fill rate, inventory level and demand-supply balance.

Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet (수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 -)

  • Ryu, Tae-Sang;Ha, Sung-Ryong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

An Analysis of Research Trends on Sustainable Supply Chain Management (지속가능공급사슬관리에 관한 연구동향 분석)

  • Joon-Seok Kim
    • Korea Trade Review
    • /
    • v.46 no.3
    • /
    • pp.203-226
    • /
    • 2021
  • Sustainability is considered to be one of the most important social and environmental requirements of modern companies located in global supply chains, since the strong worldwide regulation on carbon emission due to global warming has been emphasized. Sustainable Supply Chain Management(SSCM) could be one of the great alternatives for global companies to maintain a pleasant business environment while fulfilling their social and environmental responsibilities. This paper aims to provide research trends and future directions on SSCM through a systematic literature review. From January of 2004 to May of 2021, 185 English-written and peer-reviewed articles published in eminent journals were selected for the review. The all reviewed papers have been published in SSCI, SCI and SCIE indexed journals and should have accredited by WOS and JCR. A descriptive analysis was followed by a content analysis with regard to research design and methods, and data analysis techniques. We found that the number of research in the field of SSCM have been recently increasing and researchers and their affiliation have been expanding to all over the world, especially to emerging countries. We also found that the rate of the empirical studies and relevant research methodologies applied to the selected papers were relatively high. In the future, it is desirable to be increased the number of the specific industry-oriented research and the quantitative research pursuing the optimality.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

A Study on the Trends of Supply and the Physical Characteristics of Residents in For-profit elderly homes of Japan (일본 유료노인홈의 공급 및 입주자 특성에 관한 연구)

  • Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.15 no.3
    • /
    • pp.61-69
    • /
    • 2009
  • This study has been started in order to provide basic information for the planning of Korean elderly care facilities by analysing For-profit elderly homes of Japan. Japan is famous for her high elderly proportion and also her fast aging speed. Therefore, Japanese experiences of trials and errors related to the supply of elderly homes will be a good guideline for Korea which is undergoing the sharp increase in elderly population. Data have been mainly collected from the official statistics of Japan and Korea. The outcomes of this study are as follows. At first, the definition of For-profit elderly homes of Japan has been proposed clearly. Secondly, the trends of them related to supply and operational characteristics have been analysed. Thirdly, the size and utilization rate of them have been analysed. And finally, the physical characteristics of elderly residences in For-profit elderly homes of Japan have been discussed.

  • PDF

A Study on a Conceptual Design Process of Fuel Feeding Systems for High-Speed Vehicles (초고속 비행체 연료공급시스템 개념설계과정 연구)

  • Lee, Hyung Ju;Park, Jeongbae;Kwon, Minchan;Hwang, Ki-Young
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.7-14
    • /
    • 2013
  • Hypersonic vehicles over Mach 5 need active cooling or thermal management systems to resolve excessive heating problems on their fuselage and engines. Endothermic fuels are widely used these days not only for the energy source but also for a heat sink. Therefore, fuel supply systems of hypersonic vehicles should be mainly composed of adiabatic fuel storage tank, cooling systems for the airframe and engine/nozzle, and fuel supply/injection systems in high pressure, high temperature, and high fuel flow rate conditions. This paper describes a conceptual design process of a hypersonic fuel supply system in order for designing a layout of the system, and identifying components and their specification requirements.

Analysis on the Heat load Pattern According to Ratio of the Heat Consumers in District Heating (지역난방 열사용자 비율별 열부하 패턴변화 분석: 공동주택과 건물)

  • Lee, Hoon;Lee, Yoon-Pyo;Kim, Lae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • The district heating users can be generally classified into two groups such as apartments and buildings. In consideration that the time zone of the maximum heat load for apartments is different from those of buildings during a day, the maximum heat supply range is presented. In case of the investigated area, the maximum heat supply is occurred at the ratio between apartments and buildings that is 65%:35%. Thus the heat supply range is increased as much as 15% if the time zone when the maximum heat load is occurred is considered.

Design of Magneto-rheological Fluid Based Device (자기유변유체를 이용한 공학 장치의 설계)

  • Kim, Jeong-Hoon;Lee, Chong-Won;Jung, Byung-Bo;Park, Young-Jin;Cao, Guangzhong
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.544-549
    • /
    • 2001
  • The effect of power supply voltage on the performance limits in a laboratory Magneto-rheological fluid based device was identified by experiments. It suggests that the frequency range of motion for control be limited by the voltage attenuation due to the coil inductance and the maximum power supply voltage set for practical use of MRF devices. In this work, the magnetic and electrical characteristics of MRF device are investigated and a design procedure is formulated to achieve the desired performance for a given power supply.

  • PDF

An Experimental Study on the Ventilation performance in a Test Chamber and Office Room (모형실과 실공간에서의 환기성능에 관한 실험적 연구)

  • Yoon, Suk-Goo;Ku, Jae-Hyun;Yun, Ok-Chun;Han, Jung-Gun;Lee, Jae-Keum;Cho, Min-Chul;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.520-525
    • /
    • 2000
  • This research is to analyze the ventilation performance of mechanical ventilation systems for indoor air quality control and management. A ventilation performance with supply sites is evaluated in a test model chamber and office room. A $CO_2$ gas as a tracer gas is used to measure the ventilation performance. The ventilation performance is found to increase with increased the ventilation rate. The ventilation performance is analysed with 55% at the supply air of 570 lpm and with 20% at the supply air of 100 lpm in a test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570 lpm in office room.

  • PDF

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF