• 제목/요약/키워드: superconducting elements

검색결과 140건 처리시간 0.023초

초전도 한류기를 이용한 Bi-2223/Ag 선재의 퀜치 보호를 위한 기초 연구 (Preliminary study on the quench protection of Bi-22231 Ag tape using superconducting fault current limiter)

  • 두호익;임성우;현옥배;황시돌;조철용;박충렬;한영성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.243-244
    • /
    • 2006
  • As an preliminary study for the quench protection of high temperature superconducting (HTS) cable using superconducting fault current limiter (SFCL), experimental research was carried out. The test circuit was composed of Bi-2223/Ag HTS tape and a SFCL made of YBCO thin films. In the normal state, the applied current of 56 A, which was critical current of HTS tape, could be flown through the circuit without resistive loss. Increasing the currents, the quench development of both materials was investigated from the voltage signal acquired from the resistance of the quenched superconductor. Up to around 10 times of the critical current was applied to the HTS tape and the current limiting characteristics of SFCL were investigated. In addition, for the finding out the optimal operating condition of SFCL such as the numbers of elements, a shunt resistor was applied to the SFCL and quench characteristics were analyzed as well.

  • PDF

삼상일체화된 자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 사고유형별 퀜치발생 분석 (Analysis of Quench Generation in Fault Types According to Inductance Variation in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting)

  • 박충렬;임성훈;박형민;조용선;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.165-166
    • /
    • 2005
  • In this paper, we investigated the quench generation of HTSC elements in fault types according to inductance variation in the integrated three-phase flux-lock type SFCL. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

사고종류에 따른 삼상 일체화된 자속구속형 SFCL의 사고전류제한특성 분석 (Analysis of Fault Current limiting Characteristics According to Fault Type in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current limiting)

  • 박충렬;임성훈;박형민;조용선;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.54-56
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of HTSC elements in the integrated three-phase flux-lock type SFCL according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the three-line-to-ground fault. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

이중철심을 이용한 병렬연결된 자기결합형 초전도한류기의 전류제한 및 회복특성 (Current Limiting and Recovery Characteristics of Two Magnetically Coupled Type SFCL with Two Coils Connected in Parallel Using Dual Iron Cores)

  • 고석철;임성훈
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.717-722
    • /
    • 2016
  • 본 논문은 고장발생 초기 고장전류의 크기에 따라 피크전류제한 기능을 갖도록 하나의 철심에 기존 1차 코일과 2차 코일이 병렬로 연결된 초전도 소자 1과 추가적인 철심을 사용하여 3차 권선에 초전도 소자 2가 연결된 자기결합형 초전도한류기를 제안하였다. 이중 철심을 이용하여 코일 1과 코일 2간 병렬로 연결한 자기결합형 초전도한류기가 고장발생시 피크전류를 초전도 소자 1만이 분담하는 것을 확인할 수 있었다. 그 이유는 초기 사고전류의 순간적인 요소가 커서 초전도 소자 1이 ?치되어 작동하였으나, 코일 3에 흐르는 전류가 임계전류를 초과하지 않았고, 이로 인해 초전도 소자 2가 ?치되어 작동하지 않았기 때문이다. 사고 시 피크전류를 순차적인 초전도 소자로 제한하기 위해서는 코일 1이 낮은 자기인덕턴스 값을 갖고 있으면서도 코일 2보다 코일 3이 보다 높은 자기인덕턴스 값을 갖도록 설계해야 할 것이다. 또한, 고장 발생 초기 사고전류의 크기를 결정하는 고장조건 중의 하나인 1차 코일과 2차 코일간의 권선비가 0.25일 때 두 SFCL의 전류제한 및 회복특성에 대한 검증을 선로단락실험을 통해 분석되었다. 이 단락실험의 분석결과, 가극결선인 경우가 감극결선한 경우보다도 전류제한 및 회복특성이 더욱 우수함을 확인할 수 있었다.

자속구속형 고온초전도 전류제한기 동작 특성 (Operational characteristic of flux-lock type HTSC-FCL)

  • 임성훈;최효상;강형곤;고석철;이종화;최명호;송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.20-23
    • /
    • 2003
  • The operational characteristics of flux-lock type high-Tc superconducting fault currentlimiters(HTSC-FCLs) was described and currents equation at each coil was derived from equivalent circuit. $YBa_{2}Cu_{3}O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type HTSC-FCL, which were fabricated by etching the YBCO thin film into 2 mm wide and 420 mm long meander line consisting of foureen stripes with different length. The 2nd peak on the current of coil 2 after a fault disappeared by current of the 3rd winding, which was installed in the flux-lock type HTSC-FCL.

  • PDF

삼상형 dc reactor형태 한류기의 단락회로실험을 위한 시뮬레이션 (Simulation of the Three-phase DC Reactor Type Fault Current Limiter for the Short-circuit Test)

  • 이응로;이승제;이찬주;고태국;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.717-719
    • /
    • 2001
  • This paper deals with simulation of the three-phase dc reactor type fault current limiter(FCL). This is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. A three-phase dc reactor type FCL consists of transformers, diodes, and a superconducting coil. By this simulation for the short-circuit test we can investigate the safety of FCL's elements. And, result of simulation will contribute parameter toward optimal design.

  • PDF

Bi 초전도 박막의 부착계수 해석 (Analysis of Sticking Coefficient in Bi-Superconducting Thin film)

  • 천민우;박용필;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.997-1002
    • /
    • 2002
  • BSCCO thin films are fabricated by an ion beam sputtering method, and sticking coefficients of the respective elements are evaluated. The sticking coefficient of Bi element in BSCCO film formation was observed to show a unique temperature dependence; it was almost a constant value of 0.49 below about 730$^{\circ}C$ and decreased linearly over about 730$^{\circ}C$ In contrast, Sr and Ca, displayed no such remarkable temperature dependence. This behavior of the sticking coefficient was explained consistently on the basis of the evaporation and sublimation processes of Bi$\sub$2/O$\sub$3/. It was concluded that Bi(2212) thin film constructs from the partial melted Bi(2201) phase with the aid of the liquid phase of Bi$\sub$2/O$\sub$3/.

변화하는 자기장 하에 있는 고온초전도체에 대한 유한요소법을 이용한 2차원 수치해석 연구 (2-Dimensional Numerical Studies on Thin HTS Film under Time Varying Magnetic Field Using Finite Element Method)

  • 곽기성;이효연;이준규;염도준;유재은;한영희;박병준
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.151-157
    • /
    • 2012
  • In this paper, we used E-J constitutive law and H-formulation to calculate magnetic field profile, current density, and magnetization of high temperature superconductor (HTS) placed in time varying applied magnetic field. Finite element method (FEM)-based software, Comsol Multiphysics 3.5a, was employed to simulate 2-dimensional model of a superconducting thin strip. The numerical results based on Kim's critical state model were compared with the case of strip in a perpendicular field in the Brandt's paper as well as experimental data observed by Scanning Hall Probe and SQUID.

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF

3상 전력계통의 1선 지락사고에 대한 초전도한류기의 동작특성 (Operating properties of superconducting fault current limiters with a sing1e line-to-ground fault in a three-phase system)

  • 최효상;현옥배;김혜림;황시돌;차상도
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.261-262
    • /
    • 2003
  • We performed unsymmetrical analysis of a single line-to-ground fault in a three-phase system. The current limiting elements were meander type YBCO stripes coated with Au shunt. When the fault occurred, short circuit currents were effectively limited within 1-2 msec after fault instant. The unsymmetrical rate of fault phase was distributed from 6.4 to 1.4 and most of the fault current flowed in the grounding line due to its direct grounding system.

  • PDF